Bug 'turbinalari pt 80 100. Bug' turbinasi ishlashi to'g'risida. Petropavlovsk - Kamchatskiy

Bug 'turbinalari pt 80 100. Bug' turbinasi ishlashi to'g'risida. Petropavlovsk - Kamchatskiy

I N S T R U C T I O N

PT-80/100-130/13 LMZ.

Siz ko'rsatmalarni bilishingiz kerak:

1. qozon-turbinalar sexi boshlig‘i-2,

2. 2-qozon turbinasi sexi boshlig‘ining ekspluatatsiya bo‘yicha o‘rinbosari,

3. 2-stansiya katta smena boshlig'i,

4. 2-stansiyadagi smena boshlig'i,

5. 2-qozon-turbina sexi turbinali bo'limi smena boshlig'i,

6. VI toifali bug 'turbinalari markaziy boshqaruv punkti operatori,

7. V toifali turbinali qurilmalar bo'yicha operator-inspektor;

8. IV darajali turbinali uskunalar operatori.

Petropavlovsk - Kamchatskiy

"Kamchatskenergo" Energetika va elektrlashtirish OAJ.

"Kamchatka CHPP" filiali.

TASDIQ ETAM:

"Kamchatskenergo" OAJ KTETs filiali bosh muhandisi

Bolotenyuk Yu.N.

“ “ 20

I N S T R U C T I O N

Bug 'turbinasi foydalanish uchun qo'llanma

PT-80/100-130/13 LMZ.

Ko'rsatmaning amal qilish muddati:

bilan “____” ____________ 20

tomonidan "____"_____________ 20

Petropavlovsk - Kamchatskiy

1. Umumiy qoidalar……………………………………………………………………………………… 6

1.1. PT80/100-130/13 bug 'turbinasi xavfsiz ishlashi mezonlari………………. 7

1.2. Turbinaning texnik ma'lumotlari………………………………………………………………….. 13

1.4. Turbinani himoya qilish………………………………………………………………………………………………………… 18

1.5. Turbinani favqulodda to'xtatish va vakuumni qo'lda sindirish kerak …………… 22

1.6. Turbinani zudlik bilan to'xtatish kerak ……………………………………… 22

Turbinani tushirish va davr davomida to'xtatish kerak

elektr stantsiyasining bosh muhandisi tomonidan belgilanadi …………………………..……..… 23

1.8. Turbinaning nominal quvvatda uzoq muddatli ishlashiga ruxsat beriladi…………………… 23

2. Turbina konstruktsiyasining qisqacha tavsifi…………………………………..… 23

3. Turbina blokini moy bilan ta'minlash tizimi…………………………………..…. 25

4. Generator shaftini muhrlash tizimi……………………………………….… 26

5. Turbinani boshqarish tizimi……………………………………………. 30

6. Generatorning texnik ma’lumotlari va tavsifi………………………………….. 31

7. Kondensatorning texnik tavsifi va tavsifi…. 34

8. Regenerativ o'rnatishning tavsifi va texnik tavsifi…… 37

O'rnatishning tavsifi va texnik xususiyatlari

tarmoq suvini isitish…………………………………………………………… 42

10. Turbina blokini ishga tushirishga tayyorlash……………………………………….… 44



10.1. Umumiy qoidalar…………………………………………………………………………………………….44

10.2. Neft tizimini ishga tushirishga tayyorgarlik…………………………………….46

10.3. Boshqarish tizimini ishga tushirishga tayyorlash…………………………………………………….49

10.4. Regenerativ va kondensatsiya blokini tayyorlash va ishga tushirish…………………………49

10.5. Isitish tarmog'i suv inshootini ishga tushirishga tayyorlash………………54

10.6. Gazni qayta ishlash zavodiga bug 'quvurini isitish …………………………………………………………………………………………………………………………………………55

11. Turbinali blokni ishga tushirish……………………………………………………..… 55

11.1. Umumiy ko'rsatmalar………………………………………………………………………………….55

11.2. Turbinani sovuq holatdan ishga tushirish………………………………………………………61

11.3. Turbinani sovuq holatda ishga tushirish………………………………………………………………..64

11.4. Turbinani issiq holatdan ishga tushirish………………………………………………………..65

11.5. Yangi bug'ning sirpanish parametrlaridan foydalangan holda turbinani ishga tushirishning o'ziga xos xususiyatlari……………………..67

12. Ishlab chiqarish bug'ini chiqarishni yoqish………………………………. 67

13. Ishlab chiqarish bug'ini chiqarishni o'chirish…………………………….… 69

14. Kogeneratsion bug 'chiqarishni yoqish……………………………..…. 69

15. Kogeneratsiya bug'ini chiqarishni to'xtatish……………………………. 71

16. Turbinaning normal ishlashi vaqtida texnik xizmat ko‘rsatish………………….… 72

16.1 Umumiy qoidalar…………………………………………………………………………….72

16.2 Kondensatsiya moslamasiga texnik xizmat ko'rsatish……………………………………………………………..74

16.3 Regenerativ blokga texnik xizmat ko'rsatish…………………………………………………………………….76

16.4 Neft ta'minoti tizimiga texnik xizmat ko'rsatish ……………………………………………………………………………………87

16.5 Generatorga texnik xizmat ko‘rsatish…………………………………………………………………………………79

16.6 Isitish tarmog'iga suv ta'minoti qurilmalariga texnik xizmat ko'rsatish……………………………………80

17. Turbinani to‘xtatish…………………………………………………………… 81



17.1 Turbinani to'xtatish bo'yicha umumiy ko'rsatmalar……………………………………………………………81

17.2 Turbinani zaxira sifatida o'chirish, shuningdek sovutmasdan ta'mirlash uchun……………………..…82

17.3 Turbinani sovutish bilan ta'mirlash uchun o'chirib qo'yish…………………………………………………………84

18. Xavfsizlik talablari……………………………….……… 86

19. Turbinali avariyalarning oldini olish va bartaraf etish chora-tadbirlari…… 88

19.1. Umumiy ko'rsatmalar…………………………………………………………………………………88

19.2. Turbinani favqulodda to'xtatish holatlari…………………………………………………90

19.3. Turbinaning texnologik himoyasi tomonidan bajariladigan harakatlar……………………………91

19.4. Turbinada favqulodda vaziyat yuzaga kelganda xodimlarning harakatlari………………………………………………….92

20. Uskunalarni ta'mirlashga qabul qilish qoidalari…………………………….… 107

21. Turbinali sinovga qabul qilish tartibi………………………………….. 108

Ilovalar

22.1. Sovuq holatda turbinani ishga tushirish jadvali (metall harorati

Bug 'kirish zonasidagi yuqori bosim bosimi 150 ˚S dan kam)………………………………………………..… 109

22.2. 48 soatlik harakatsizlikdan keyin turbinani ishga tushirish jadvali (metall harorati

Bug 'kirish zonasidagi HPC 300 ˚S)…………………………………………………………..110

22.3. 24 soatlik harakatsizlikdan keyin turbinani ishga tushirish jadvali (metall harorati

Bug 'qabul qilish zonasida HPC 340 ˚S)……………………………………………………………………………111

22.4. 6-8 soat harakatsizlikdan keyin turbinani ishga tushirish jadvali (metall harorati

Bug 'kirish zonasidagi HPC 420 ˚S)…………………………………………………………………………….112

22.5. Turbinani ishga tushirish jadvali 1-2 soat bo'sh vaqtdan keyin (metall harorati

Bug 'kirish zonasida HPC 440 ˚S)…………………………………………………………………113

22.6. Nominalda turbinani ishga tushirishning taxminiy jadvallari

yangi bug 'parametrlari……………………………………………………………………………….…114

22.7. Turbinaning uzunlamasına kesimi…………………………………………………………..….…115

22.8. Turbinani boshqarish sxemasi………………………………………………………..116

22.9. Turbina blokining issiqlik diagrammasi…………………………………………………………….….118

23. Qo‘shimchalar va o‘zgartirishlar…………………………………………………. 119

UMUMIY QOIDALAR.

PT-80/100-130/13 LMZ tipidagi bug 'turbinasi ishlab chiqarish va 2 bosqichli kogeneratsiyali bug' chiqarish, nominal quvvati 80 MVt va maksimal 100 MVt (boshqariladigan ekstraktsiyalarning ma'lum kombinatsiyasida) TVF-110 ni to'g'ridan-to'g'ri haydash uchun mo'ljallangan. -2E o'zgaruvchan tok generatori U3 quvvati 110 MVt, turbinali umumiy poydevorga o'rnatilgan.

Qisqartmalar va belgilar ro'yxati:

AZV - avtomatik yuqori bosimli valf;

VPU - milni burish moslamasi;

GMN - asosiy moy nasosi;

GPZ - asosiy bug 'klapan;

KOS - servomotorli nazorat valfi;

KEN - kondensatli elektr nasos;

MUT - turbinani boshqarish mexanizmi;

OM - quvvat cheklovchisi;

HPH - yuqori bosimli isitgichlar;

LPH - past bosimli isitgichlar;

PMN - ishga tushirish moy pompasi;

PN - bug 'sovutgichining muhri;

PS - ejektorli bug 'sovutgichining muhri;

PSG-1 - pastki ekstraktsiyaning tarmoqli isitgichi;

PSG-2 - bir xil, yuqori tanlov;

PEN - elektr oziqlantiruvchi nasos;

HPR - yuqori bosimli rotor;

RK - nazorat klapanlari;

RND - past bosimli rotor;

RT - turbinali rotor;

HPC - yuqori bosimli silindr;

LPC - past bosimli silindr;

RMN - zaxira moy nasosi;

AMN - favqulodda moy nasosi;

RPDS - moylash tizimidagi yog 'bosimining pasayishi rölesi;

Ppr - ishlab chiqarish namunasi kamerasidagi bug 'bosimi;

P - pastki isitish kamerasidagi bosim;

R - bir xil, yuqori isitish ekstraktsiyasi;

Dpo - ishlab chiqarishni qazib olish uchun bug 'iste'moli;

D - PSG-1,2 uchun umumiy oqim tezligi;

KAZ - avtomatik yopish valfi;

MNUV - generator mili muhr yog 'nasosi;

NOG - generator sovutish pompasi;

ACS - avtomatik boshqaruv tizimi;

EGP - elektrogidravlik konvertor;

KIS - ijro etuvchi solenoid klapan;

TO - isitishning ekstraktsiyasi;

PO - ishlab chiqarishni tanlash;

MO - moy sovutgichi;

RPD - differentsial bosim regulyatori;

PSM - mobil moy ajratuvchi;

ZG - gidravlik panjur;

BD - damper tanki;

IM - yog 'injektori;

RS - tezlikni boshqarish moslamasi;

RD - bosim regulyatori.


1.1.1. Turbina quvvatiga ko'ra:

To'liq yoqilganda turbinaning maksimal quvvati

regeneratsiya va ishlab chiqarishning muayyan kombinatsiyalari va

issiqlik qazib olish…………………………………………………………………100 MVt

Ikkilamchi HPV-5, 6, 7 bilan kondensatsion rejimda kondensatsion rejimida maksimal turbin quvvat ... MVt

PND-2, 3, 4 o'chirilgan holda kondensatsiya holatida maksimal turbinaning quvvati ………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………….

O'chirilganda kondensatsiya rejimida turbinaning maksimal quvvati

PND-2, 3, 4 va PVD-5, 6, 7 ……………………………………………………………………………….68 MVt.

PVD-5,6,7………………………………………………………..10 MVt foydalanishga kiritilgan.

Kondensatsiya rejimida turbinaning minimal quvvati

PND-2 drenaj nasosini yoqadi……………………………………….20 MVt.

U yoqilgan turbina blokining minimal quvvati

sozlanishi turbinali ekstraktsiyalarning ishlashi ……………………………………………………………… 30 MVt

1.1.2. Turbinaning rotor tezligiga qarab:

Turbina rotorining nominal tezligi ……………………………………………………..3000 rpm

Turbina rotorining nominal aylanish tezligi

qurilma ………………………………………………………………………………………………………..3.4 rpm

Turbina rotori tezligining maksimal og'ishi da

turbina bloki himoya bilan o'chirilgan …………………………………………………..…..3300 rpm.

3360 aylanish tezligi

Turbogenerator rotorining kritik aylanish tezligi………………………………….1500 rpm.

Past bosimli turbinali rotorning kritik aylanish tezligi …………………….……1600 rpm.

Yuqori bosimli turbinali rotorning kritik aylanish tezligi ……………………….….1800 rpm.

1.1.3. Turbinaga o'ta qizib ketgan bug'ning oqimiga ko'ra:

Kondensatsiya rejimida ishlaganda turbina uchun nominal bug 'oqimi

regeneratsiya tizimi to'liq yoqilgan holda (nominal quvvatda

turbinali blok 80 MVt ga teng) …………………………………………………………………………………305 t/soat

Tizim yoqilganda turbinaga maksimal bug 'oqimi

regeneratsiya, tartibga solinadigan ishlab chiqarish va isitish qazib olish

va yopiq nazorat klapan №5 …..……………………………………………………………..415 t/soat

Bir turbinaga maksimal bug 'oqimi…………………………………………………………………………………………………………………………………………………………………….

o'chirilgan rejimda PVD-5, 6, 7 …………………………………………………………..270 t/soat

Kondensatsiyada ishlaganda turbina uchun maksimal bug 'oqimi

LPG-2, 3, 4 ………………………………………………………………………………………………………………..260t/soat o‘chirilgan rejim

Kondensatsiyada ishlaganda turbina uchun maksimal bug 'oqimi

PND-2, 3, 4 va PVD-5, 6, 7…………………………………………………………………..…230t/soat o‘chirilgan rejim

1.1.4. CBA oldidan qizib ketgan bug'ning mutlaq bosimiga ko'ra:

O'ta qizib ketgan bug'ning yadro oldidagi nominal mutlaq bosimi……………………………….130 kgf/sm 2

O'ta qizib ketgan bug'ning mutlaq bosimining ruxsat etilgan kamayishi

turbinaning ishlashi paytida CBA oldida…………………………………………………………125 kgf/sm 2

Qizigan bug'ning mutlaq bosimining ruxsat etilgan ortishi

turbinaning ishlashi paytida CBA oldida.…………………………………………………………………………………135 kgf/sm 2.

CBA dan oldin qizib ketgan bug'ning mutlaq bosimining maksimal og'ishi

turbinaning ishlashi paytida va har bir og'ishning davomiyligi 30 daqiqadan ko'p bo'lmagan ……..140 kgf / sm 2

1.1.5. CBAgacha qizdirilgan bug'ning harorati asosida:

O'ta qizigan bug'ning yadro oldidagi nominal harorati..………………………………..…..555 0 S

Haddan tashqari qizib ketgan bug 'haroratining ruxsat etilgan pasayishi

turbinaning ishlashi paytida CBA dan oldin..……………………………………………………………………… 545 0 C

Oldin o'ta qizib ketgan bug'ning haroratining ruxsat etilgan ortishi

Turbinaning ishlashi paytida CBA …………………………………………………………………………………………………………………………….. 560 0 C

O'ta qizib ketgan bug'ning yadrodan oldin maksimal harorat og'ishi da

turbinaning ishlashi va har bir og'ishning davomiyligi 30 dan oshmaydi

daqiqa………………………………………………………………………………………………………………565 0 C

O'ta qizib ketgan bug'ning CBA dan oldin minimal harorat og'ishi

turbina bloki himoya bilan o'chirilgan bo'lsa ……………………………………………………………………………………...425 0 S

1.1.6. Turbinani boshqarish bosqichlarida mutlaq bug' bosimiga asoslanib:

turbinaga o'ta qizdirilgan bug 'oqimlari bilan soatiga 415 t gacha. ..………………………………………98,8 kgf/sm 2

HPC ning nazorat bosqichida maksimal mutlaq bug 'bosimi

turbina PVD-5, 6, 7 o'chirilgan holda kondensatsiya rejimida ishlaganda….……….…64 kgf/sm 2

HPC ning nazorat bosqichida maksimal mutlaq bug 'bosimi

turbina LPG-2, 3, 4 o'chirilgan holda kondensatsiya rejimida ishlaganda ………….…62 kgf/sm 2

HPC ning nazorat bosqichida maksimal mutlaq bug 'bosimi

turbina PND-2, 3, 4 o'chirilgan holda kondensatsiya rejimida ishlaganda

va PVD-5, 6,7……………………………………………………………………………………… .....55 kgf / sm 2

Yoqilg'i quyish kamerasida maksimal mutlaq bug 'bosimi

Turbinaga o'ta qizib ketgan bug'ning oqim tezligida HPC klapan (4 bosqichli orqada)

415 t/soatdan ortiq………………………………………………………………………………83 kgf/sm 2

Tekshirish kamerasida maksimal mutlaq bug 'bosimi

LPC qadamlari (18-bosqich ortida) …………………………………………………………………………..13,5 kgf/sm 2

1.1.7. Regulyatsiya qilingan turbinada mutlaq bug' bosimiga ko'ra:

Mutlaq bug 'bosimining ruxsat etilgan o'sishi

nazorat ostida ishlab chiqarishni tanlash……………………………………………………16 kgf/sm 2

Mutlaq bug 'bosimining ruxsat etilgan pasayishi

nazorat ostida ishlab chiqarishni tanlash……………………………………………………10 kgf/sm 2

Xavfsizlik klapanlari faollashtirilgan tartibga solinadigan ishlab chiqarish ekstraktidagi mutlaq bug' bosimining maksimal og'ishi ……………………………………………………………………………………… .19,5 kgf/sm 2

yuqori isitish ekstraktsiyasi ………………………………………………………….…..2,5 kgf/sm 2

yuqori isitish ekstraktsiyasi ……………………………………………………………………..0,5 kgf/sm 2

Regulyatsiyada mutlaq bug 'bosimining maksimal og'ishi

u ishga tushiriladigan yuqori isitish tanlovi

xavfsizlik valfi…………………………………………………………………………………………………3,4 kgf/sm 2

Mutlaq bug 'bosimining maksimal og'ishi

unda nazorat ostida yuqori isitish ekstraktsiyasi

turbina bloki himoya bilan o'chirilgan ……………………………………………………………………………………………….3,5 kgf/sm 2

Regulyatsiya qilingan mutlaq bug 'bosimining ruxsat etilgan ortishi

kamroq isitish ekstraktsiyasi …………………………………………………………………………1 kgf/sm 2

Regulyatsiya qilingan bug'ning mutlaq bosimining ruxsat etilgan kamayishi

kamroq isitish ekstraktsiyasi………………………………………………………….…0,3 kgf/sm 2

Kamera orasidagi bosim farqining ruxsat etilgan maksimal kamayishi

pastroq isitish ekstraktsiyasi va turbinali kondensator………………………….… 0,15 kgf/sm 2 gacha

1.1.8. Boshqariladigan turbina ekstraktsiyalariga bug 'oqimi bo'yicha:

Regulyatsiya qilingan ishlab chiqarishda nominal bug 'oqimi

tanlash………………………………………………………………………………………………185 t/soat

Boshqariladigan ishlab chiqarishda maksimal bug 'oqimi ...

nominal turbina quvvati va o'chirilgan

isitish ekstraktsiyasi ………………………………………………………………………………………………………245 t/soat

Boshqariladigan ishlab chiqarishda maksimal bug 'oqimi

unda 13 kgf / sm 2 ga teng mutlaq bosimda tanlash,

turbinaning quvvati 70 MVt ga tushirildi va o'chirildi

isitish ekstrakti………………………………………………………………………………300 t/soat

Nominal bug 'oqimi sozlanishi tepada

isitish qazib olish……………………………………………………………………………………132 t/soat

va nogiron ishlab chiqarishni tanlash……………………………………………………150 t/soat

Sozlanishi tepada maksimal bug 'oqimi

markazlashtirilgan isitish quvvati 76 MVtgacha qisqartirildi

turbinali va o'chirilgan ishlab chiqarishni qazib olish ……………………………………………………….………220 t/soat

Sozlanishi tepada maksimal bug 'oqimi

nominal turbinali quvvatda isitish ekstraktsiyasi

va ishlab chiqarishni tanlashda 40 t/soat bug‘ sarfi ……………………………200 t/soatgacha kamaytirildi.

PSG-2da mutlaq bosimda maksimal bug 'oqimi

yuqori isitish ekstraktsiyasida 1,2 kgf/sm 2 …………………………………………….…145 t/soat.

PSG-1da mutlaq bosimdagi maksimal bug 'oqimi

pastki isitish ekstraktsiyasida 1 kgf/sm2 …………………………………………………….220 t/soat.

1.1.9. Turbina chiqishidagi bug' haroratiga qarab:

Regulyatsiya qilingan ishlab chiqarishda nominal bug 'harorati

OU-1, 2 (3,4) dan keyin tanlash …………………………………………………………………………………..280 0 C

Nazorat ostidagi bug 'haroratining ruxsat etilgan ko'tarilishi

OU-1, 2 (3,4) dan keyin ishlab chiqarish tanlovi ……………………………………………………………285 0 S

Nazorat ostidagi bug 'haroratining ruxsat etilgan pasayishi

OU-1.2 (3.4) dan keyin ishlab chiqarishni tanlash …………………………………………………………….…275 0 S

1.1.10. Turbinaning termal holatiga ko'ra:

Metall harorat ko'tarilishining maksimal tezligi

…..……………………………...15 0 S/min.

ABC dan HPC ning nazorat klapanlariga bypass quvurlari

450 darajadan past bo'lgan o'ta qizib ketgan bug'ning haroratida.…………………………………….………25 0 C.

Maksimal ruxsat etilgan metall harorat farqi

ABC dan HPC ning nazorat klapanlariga bypass quvurlari

450 darajadan yuqori qizdirilgan bug 'haroratida.………………………………………………………….20 0 C.

Yuqori metallning ruxsat etilgan maksimal harorat farqi

va bug 'kirish zonasidagi HPC (LPC) pastki qismi ………………….………………………………………..50 0 S

Maksimal ruxsat etilgan metall harorat farqi

gorizontal troyniklarning kesmasi (kengligi).

isitish tizimini yoqmasdan silindrli ulagich

HPC gardishlari va tirgaklari..…………………………………………………………………………80 0 C

……………………………………………………………..…50 0 C ustidagi troyniklar va tirgaklarni isitish bilan HPC ulagichi

gorizontal troyniklarning kesimida (kengligida).

Flanjlar va tirgaklarni isitish bilan HPC ulagichi……………………………….……-25 0 C

Yuqori o'rtasidagi ruxsat etilgan maksimal metall harorat farqi

va HPC ning pastki (o'ng va chap) gardishlari

troyniklar va tirgaklarni qizdirish ……………………………………………………………………………….10 0 S

Metallning maksimal ruxsat etilgan ijobiy harorat farqi

isitish yoqilganda HPC ning gardishlari va tirgaklari o'rtasida

gardish va tirgaklar…………………………………………………………………………………….20 0 C

Metallning maksimal ruxsat etilgan salbiy harorat farqi

Flanjlar va tirgaklarni isitish yoqilganda HPC ning gardishlari va tirgaklari o'rtasida ………………………………………………………………………………… ………………………..…..- 20 0 S

Metall qalinligining maksimal ruxsat etilgan harorat farqi

silindr devorlari, yuqori bosimli silindrni boshqarish bosqichida o'lchangan….………………………….35 0 S

podshipniklar va turbinali podshipniklar…………………………………….…………..90 0 C

Qo'llab-quvvatlash qoplamalarining ruxsat etilgan maksimal harorati

generator podshipniklari…………………………………………………………………………………………………………………..80 0 C

1.1.11. Turbinaning mexanik holatiga ko'ra:

Markaziy venoz bosimga nisbatan yuqori bosimli shlangning ruxsat etilgan maksimal qisqarishi……………………………….-2 mm

Markaziy venoz bosimga nisbatan yuqori bosimli shlangning ruxsat etilgan maksimal cho'zilishi …………………………………….+3 mm

LPC ga nisbatan RND ning ruxsat etilgan maksimal qisqarishi ……………………..………-2,5 mm

LPC ga nisbatan RNDning ruxsat etilgan maksimal cho'zilishi …………………………..…….+3 mm

Turbina rotorining ruxsat etilgan maksimal egriligi…………….……………………………..0,2 mm

Egrilikning maksimal ruxsat etilgan maksimal qiymati

kritik aylanish tezligidan o'tganda turbinali blok mili ………………………..0,25 mm

generator tomoni………………………………………………………………………………..…1,2 mm

Turbina rotorining ruxsat etilgan maksimal eksenel siljishi

boshqaruv blokining yon tomoni ……………………………………………………………….………………….1,7 mm

1.1.12. Turbina blokining tebranish holatiga ko'ra:

Turbina bloklari podshipniklarining ruxsat etilgan maksimal tebranish tezligi

barcha rejimlarda (kritik aylanish tezligidan tashqari) …………….………………………….4,5 mm/sek

podshipniklarning tebranish tezligi sekundiga 4,5 mm dan oshganda……………………………30 kun.

Turbina blokining ruxsat etilgan maksimal ish vaqti

podshipniklarning tebranish tezligi sekundiga 7,1 mm dan oshganda…………………………7 kun

Har qanday rotor tayanchlarining tebranish tezligining favqulodda oshishi ………….……………………11,2 mm/sek

Favqulodda vaziyatda tebranish tezligining bir vaqtning o'zida ikkiga oshishi

bitta rotorning tayanchlari yoki qo'shni tayanchlar yoki ikkita tebranish komponenti

har qanday boshlang‘ich qiymatdan bitta qo‘llab-quvvatlash……………………………………………1 mm yoki undan ortiq

1.1.13. Aylanma suvning oqimi, bosimi va harorati bo'yicha:

Turbina bloki uchun jami sovutish suvi sarfi………………………………….8300 m 3 / soat

Kondenser orqali maksimal sovutish suvi oqimi………………………………..8000 m3/soat

Kondenser orqali minimal sovutish suvi oqimi……………….…………………..2000 m3 / soat

O'rnatilgan kondensator to'plami orqali maksimal suv oqimi……….………………1500 m3 / soat

O'rnatilgan kondensator to'plami orqali minimal suv oqimi ………………………..300 m 3 / soat

Kondensator kirishidagi sovutish suvining maksimal harorati……………………………………………………………………………………..33 0 S

Kirish joyida aylanma suvning minimal harorati

tashqi havo harorati noldan past bo'lgan davrda kondensator ………………………….8 0 C

TsN-1,2,3,4 sirkulyatsiya nasoslarining AVRi ishlaydigan aylanma suvning minimal bosimi……………………………………………………………………… ……..0,4 kgf/sm 2

Quvurlar tizimidagi aylanma suvning maksimal bosimi

kondansatörning chap va o'ng yarmi ……………………………………….……….……….2,5 kgf/sm 2

Quvurlar tizimidagi maksimal mutlaq suv bosimi

o'rnatilgan kondansatör nuri …………………………………………………………….8 kgf/sm 2

Kondenserning nominal gidravlik qarshiligi at

toza quvurlar va aylanma suv oqimi tezligi 6500 m 3 / soat …………………………………………………..3,8 m suv. Art.

O'rtasidagi aylanma suvning maksimal harorat farqi

uning kondansatkichga kirishi va chiqishi ……………………………………………………………..10 0 C

1.1.14. Kondensatorga bug 'va kimyoviy tuzsizlangan suvning oqim tezligi, bosimi va harorati bo'yicha:

Kimyoviy tuzsizlangan suvning kondensatorga maksimal oqish tezligi ………………..…………………..100 t/soat.

Barcha rejimlarda kondensatorga maksimal bug 'oqimi

operatsiya………………………………………………………………………………………220 t/soat.

Past bosimli turbinali turbinasi orqali kondensatorga minimal bug 'oqimi

yopiq aylanadigan diafragma bilan ……………………………………………………….……10 t/soat.

LPC ning egzoz qismining ruxsat etilgan maksimal harorati ……………………….……..70 0 S

Kimyoviy tuzsizlangan suvning ruxsat etilgan maksimal harorati,

kondensatorga kirish ………………………………………………………….………100 0 C

Past bosimli nasosning egzoz qismidagi mutlaq bug 'bosimi

atmosfera diafragma klapanlari faollashtirilgan …………………………………………..……..1,2 kgf/sm 2

1.1.15. Turbina kondensatoridagi mutlaq bosim (vakuum) asosida:

Kondensatordagi nominal mutlaq bosim……………………………………………0,035 kgf/sm 2

Ogohlantirish signali ishga tushirilgan kondensatordagi vakuumning ruxsat etilgan pasayishi ………………. ……………………………………………………-0,91 kgf/sm 2

Kondensatorda vakuumni favqulodda kamaytirish

Turbina bloki himoya bilan o'chirilgan …………… ………………………………………………………………………………………………….-0,75 kgf/sm 2

unga issiq oqimlarni quyish orqali……………………………………………………………….….-0,55 kgf/sm 2

Turbinani oldin ishga tushirganda kondanserda ruxsat etilgan vakuum

turbina milini surish ……………………………………………………………………………………………………-0,75 kgf/sm 2

Turbinani oxirida ishga tushirishda kondanserda ruxsat etilgan vakuum

1000 rpm chastotali rotorining aylanish chidamliligi …………….…………………..…….-0,95 kgf/sm 2

1.1.16. Bir juft turbinali muhrning bosimi va haroratiga ko'ra:

Turbina qistirmalarida minimal mutlaq bug 'bosimi

bosim regulyatorining orqasida……………………………………………………………………….1,1 kgf/sm 2

Turbina qistirmalaridagi maksimal mutlaq bug 'bosimi

bosim regulyatorining orqasida……………………………………………………………………………….1,2 kgf/sm 2

Turbina qistirmalari orqasidagi minimal mutlaq bug 'bosimi

bosimni saqlash regulyatoriga …………………………………………………….….1,3 kgf/sm 2

Turbina qistirmalari orqasidagi maksimal mutlaq bug 'bosimi...

bosimni saqlash regulyatoriga …………………………………………………..….1,5 kgf/sm 2

Ikkinchi muhr kameralaridagi minimal mutlaq bug 'bosimi…………………….1,03 kgf/sm 2

Ikkinchi muhr kameralarida maksimal mutlaq bug 'bosimi ……………………..1,05 kgf/sm 2

Plombalardagi nominal bug' harorati………………………………………………….150 0 S

1.1.17. Turbina blokining podshipniklarini moylash uchun moy bosimi va haroratiga qarab:

Rulman moylash tizimidagi nominal ortiqcha yog 'bosimi

yog 'sovuguncha turbina.…………………………………………………………………………………………..3 kgf/sm 2.

Soqol tizimidagi nominal ortiqcha yog 'bosimi

turbina blokining mili o'qi darajasidagi podshipniklar ……………………………………………………………………….1 kgf/sm 2

u ishga tushirilgan turbina blokining mil o'qi darajasida

ogohlantirish signali……………………………………………………………………………..0,8 kgf/sm 2

Rulman moylash tizimidagi ortiqcha yog 'bosimi

RPM yoqilgan turbina blokining mil o'qi darajasida ………………………………….0,7 kgf/sm 2

Rulman moylash tizimidagi ortiqcha yog 'bosimi

AMS yoqilgan turbina blokining mil o'qi darajasida ……………………………..….0,6 kgf/sm 2

Rulmanning moylash tizimidagi ortiqcha yog 'bosimi darajasida

VPU himoya bilan o'chirilgan turbina bloki milining o'qi ……………………………..…0,3 kgf/sm 2

Rulman soqol tizimidagi favqulodda ortiqcha yog 'bosimi

turbina bloki himoya bilan o'chirilgan turbina mili o'qi darajasida ………………………………………………………………………………………………………………………………… …….…………..0 ,3 kgf/sm 2

Turbina bloklari podshipniklarini moylash uchun nominal moy harorati……………………..40 0 S

Rulmanlarni moylash uchun ruxsat etilgan maksimal yog 'harorati

turbinali blok ……………………………………………………………………………………….…45 0 C

Chiqishdagi maksimal ruxsat etilgan yog 'harorati

turbinali podshipniklar…………………………………………………………………………………………………………………………………………………………………………………………………………………………….

Rulman drenajidagi favqulodda yog 'harorati

turbinali blok…………………………………………………………………………………………………………………………………75 0 C

1.1.18. Turbinani boshqarish tizimidagi moy bosimiga qarab:

PMP tomonidan yaratilgan turbinani boshqarish tizimidagi ortiqcha yog 'bosimi ………………………………………………………………………………………………………………………………………………………………. …18 kgf/sm 2

Gidravlik nasos tomonidan yaratilgan turbinani boshqarish tizimidagi ortiqcha yog 'bosimi …………………………………………………………………………………………………………… …..20 kgf/sm 2

Turbinani boshqarish tizimida ortiqcha yog 'bosimi

Bunda bosim ostida valfni yopish va PMP ni o'chirish taqiqlanadi…………….17,5 kgf/sm 2

1.1.19. Turbogenerator milya muhr tizimidagi bosim, daraja, oqim va moy haroratiga qarab:

ATS tomonidan zaxira o'zgaruvchan tok MNUV yoqilgan turbogenerator milya muhr tizimidagi ortiqcha yog 'bosimi………………………………………………………8 kgf/sm 2

ATS faollashtirilgan turbogenerator shaftining muhr tizimida ortiqcha yog 'bosimi

zaxira MNUV to'g'ridan-to'g'ri oqim ………………………………………………………………..7 kgf/sm 2

Mil qistirmalaridagi yog 'bosimi va turbogenerator korpusidagi vodorod bosimi o'rtasidagi ruxsat etilgan minimal farq …………………………..0,4 kgf/sm 2

Mil qistirmalaridagi yog 'bosimi va turbogenerator korpusidagi vodorod bosimi o'rtasidagi ruxsat etilgan maksimal farq ……………………………………………………………………….0,8 kgf/sm 2

Yog 'kirish bosimi va bosimi o'rtasidagi maksimal farq

MFG chiqishidagi moy, bunda generatorning zaxira moy filtriga o'tish kerak……………………………………………………………………… …………………….1 kgf/sm 2

MOG dan chiqish joyidagi nominal moy harorati………………………………………………………..40 0 C

MOG dan chiqish joyida yog 'haroratining ruxsat etilgan ko'tarilishi…………………….…….…….45 0 S

1.1.20. Turbinali HH guruhi orqali ozuqa suvining harorati va oqim tezligiga qarab:

HPH guruhiga kirishda ozuqa suvining nominal harorati ………………………….164 0 S

Turbina blokining nominal quvvati bo'yicha HPH guruhining chiqishidagi ozuqa suvining maksimal harorati …………………………………………………………..…249 0 S

HPH quvurlari tizimi orqali maksimal suv oqimi ………………………….550 t/soat

1.2.Turbinaning texnik ma'lumotlari.

Turbinaning nominal quvvati 80 MVt
Rejim diagrammasi bilan aniqlangan ishlab chiqarish va isitishning ma'lum kombinatsiyalari uchun to'liq yoqilgan regeneratsiya bilan maksimal turbinaning quvvati 100 MVt
Mutlaq yangi bug 'bosimi avtomatik o'chirish valfi 130 kgf/sm²
To'xtatish valfidan oldin bug 'harorati 555 °C
Kondensatorning mutlaq bosimi 0,035 kgf/sm²
Barcha ekstraktsiyalar va ularning har qanday kombinatsiyasi bilan ishlaganda turbina orqali maksimal bug 'oqimi 470 t/soat
Kondensatorga maksimal bug 'o'tishi 220 t/soat
Sovutish suvi kondensatorga 20 °C kondanser kirishida dizayn haroratida oqadi. 8000 m³/soat
Boshqariladigan ishlab chiqarish ekstraktsiyasining mutlaq bug 'bosimi 13±3 kgf/sm²
Sozlanishi yuqori isitish ekstraktsiyasining mutlaq bug 'bosimi 0,5 - 2,5 kgf / sm²
Bir bosqichli tarmoqli suv isitish sxemasi bilan boshqariladigan quyi markazlashtirilgan issiqlik chiqarishning mutlaq bug' bosimi 0,3 - 1 kgf / sm²
HPH dan keyin ozuqa suvining harorati 249 °C
Maxsus bug 'iste'moli (LMZ tomonidan kafolatlangan) 5,6 kg/kVt/soat

Eslatma: Tebranishning kuchayishi (o'zgarishi) tufayli to'xtatilgan turbina blokini ishga tushirishga faqat tebranish sabablari batafsil tahlil qilinganidan keyin va elektr stantsiyasining bosh muhandisining ruxsati bilan uning shaxsan o'zi tomonidan ekspluatatsiya jurnalida ruxsat etiladi. stantsiya navbatchisi.

1.6 Quyidagi hollarda turbinani darhol to'xtatish kerak:

· 3360 rpm dan yuqori aylanish tezligini oshirish.

· Neft quvurlari, bug‘-suv yo‘li va bug‘ taqsimlash moslamalarining almashtirib bo‘lmaydigan qismlarida yorilish yoki yoriqni aniqlash.

· Yangi bug 'liniyalarida yoki turbinada gidravlik shoklarning paydo bo'lishi.

· Vakuumni -0,75 kgf/sm² gacha favqulodda kamaytirish yoki atmosfera klapanlarini faollashtirish.

Yangi oziq-ovqat haroratining keskin pasayishi

TEXNIK TAVSIFI

Ob'ektning tavsifi.
To'liq ism:
“PT-80/100-130/13 turbinasidan foydalanish” avtomatlashtirilgan o‘quv kursi.
Belgisi:
Ishlab chiqarilgan yili: 2007.

PT-80/100-130/13 turbinasidan foydalanish bo'yicha avtomatlashtirilgan o'quv kursi ushbu turdagi turbinali bloklarga xizmat ko'rsatadigan operatsion xodimlarni o'qitish uchun ishlab chiqilgan va o'qitish, imtihondan oldin tayyorgarlik ko'rish va issiqlik quvvatini imtihondan o'tkazish vositasidir. zavod xodimlari.
AUK PT-80/100-130/13 turbinalarini ishlatishda qo'llaniladigan me'yoriy-texnik hujjatlar asosida tuzilgan. Unda interfaol ta'lim va talabalarni test qilish uchun matn va grafik materiallar mavjud.
Ushbu AUK PT-80/100-130/13 isitish turbinalarining asosiy va yordamchi uskunalarining konstruktiv va texnologik xususiyatlarini tavsiflaydi, xususan: asosiy bug 'klapanlari, to'xtash klapanlari, nazorat klapanlari, HPC ning bug' kirishi, HPC ning konstruktiv xususiyatlari , CSD, LPC, turbinali rotorlar, podshipniklar, burilish moslamasi, muhrlash tizimi, kondensatsiya bloki, past bosimli regeneratsiya, besleme nasoslari, yuqori bosimli regeneratsiya, isitish moslamasi, turbin moy tizimi va boshqalar.
Turbinali blokning ishga tushirish, normal, favqulodda va to'xtash rejimlari, shuningdek, bug 'trubalarini, valf bloklarini va turbinali tsilindrlarni isitish va sovutish uchun asosiy ishonchlilik mezonlari ko'rib chiqiladi.
Turbinani avtomatik boshqarish tizimi, himoya qilish, blokirovkalash va signalizatsiya tizimi ko'rib chiqiladi.
Uskunalarni tekshirish, sinovdan o‘tkazish va ta’mirlashga qabul qilish tartibi, xavfsizlik qoidalari hamda portlash va yong‘in xavfsizligi qoidalari belgilandi.

AUC tarkibi:

Avtomatlashtirilgan o'quv kursi (ATC) - bu elektr stantsiyalari va elektr tarmoqlarida xodimlarni dastlabki tayyorlash va keyingi bilimlarini sinovdan o'tkazish uchun mo'ljallangan dasturiy vosita. Avvalo, operatsion va texnik xodimlarni o'qitish uchun.
AUC asosini joriy ishlab chiqarish va ish tavsiflari, me'yoriy materiallar va uskunalar ishlab chiqaruvchilarning ma'lumotlari tashkil etadi.
AUC quyidagilarni o'z ichiga oladi:
— umumiy nazariy ma’lumotlar bo‘limi;
— muayyan turdagi asbob-uskunalarni loyihalash va ishlatish qoidalarini muhokama qiladigan bo'lim;
— talabalarning o‘z-o‘zini tekshirish bo‘limi;
- imtihonchi bloki.
Matnlardan tashqari, AUK zarur grafik materiallarni (diagrammalar, chizmalar, fotosuratlar) o'z ichiga oladi.

AUC ning axborot mazmuni.

1. Matn materiali foydalanish yo'riqnomasi, PT-80/100-130/13 turbinasi, zavod yo'riqnomasi, boshqa me'yoriy-texnik materiallar asosida tuzilgan va quyidagi bo'limlarni o'z ichiga oladi:

1.1. PT-80/100-130/13 turbina blokining ishlashi.
1.1.1. Turbina haqida umumiy ma'lumot.
1.1.2. Yog 'tizimi.
1.1.3. Tartibga solish va himoya qilish tizimi.
1.1.4. Kondensatsiyalash moslamasi.
1.1.5. Regenerativ o'rnatish.
1.1.6. Isitish tarmog'idagi suv uchun o'rnatish.
1.1.7. Turbinani ishga tayyorlash.
Yog 'tizimini va VPUni tayyorlash va ishga tushirish.
Turbinani boshqarish va himoya qilish tizimini tayyorlash va ishga tushirish.
Himoya vositalarini sinovdan o'tkazish.
1.1.8. Kondensatsiya moslamasini tayyorlash va ishga tushirish.
1.1.9. Regenerativ o'rnatishni tayyorlash va ishga tushirish.
1.1.10. Isitish tarmog'idagi suv uchun o'rnatishni tayyorlash.
1.1.11. Turbinani ishga tushirishga tayyorlash.
1.1.12. Har qanday holatdan turbinani ishga tushirishda bajarilishi kerak bo'lgan umumiy ko'rsatmalar.
1.1.13. Turbinani sovuq holatdan ishga tushirish.
1.1.14. Turbinani issiq holatdan ishga tushirish.
1.1.15. Ishlash rejimi va parametrlarni o'zgartirish.
1.1.16. Kondensatsiya rejimi.
1.1.17. Ishlab chiqarish va isitish uchun tanlovlar bilan rejim.
1.1.18. Yukni tushirish va yuklash.
1.1.19. Turbinani to'xtatish va tizimni asl holatiga qaytarish.
1.1.20. Texnik holati va texnik holatini tekshirish. Xavfsizlik tekshiruvlari uchun vaqt.
1.1.21. Soqol tizimi va VPUga texnik xizmat ko'rsatish.
1.1.22. Kondensatsiya va regenerativ zavodga texnik xizmat ko'rsatish.
1.1.23. Isitish tarmog'i suv uchun o'rnatishga texnik xizmat ko'rsatish.
1.1.24. Turbogeneratorga xizmat ko'rsatishda xavfsizlik choralari.
1.1.25. Turbinali bloklarga xizmat ko'rsatishda yong'in xavfsizligi.
1.1.26. Xavfsizlik klapanlarini sinovdan o'tkazish tartibi.
1.1.27. Ilova (himoya).

2. Ushbu AUCdagi grafik material 15 ta chizma va diagrammada keltirilgan:
2.1. PT-80/100-130-13 turbinasining uzunlamasına kesimi (HPC).
2.2. PT-80/100-130-13 (TSSND) turbinasining uzunlamasına kesimi.
2.3. Bug 'chiqarish quvurlari sxemasi.
2.4. Turbogeneratorning neft quvurlari diagrammasi.
2.5. Plombalardan bug'ni etkazib berish va so'rish sxemasi.
2.6. To'ldirish qutisi isitgichi PS-50.
2.7. PS-50 to'ldirish qutisi isitgichining xususiyatlari.
2.8. Turbogeneratorning asosiy kondensati diagrammasi.
2.9. Tarmoqli suv quvurlari diagrammasi.
2.10. Bug '-havo aralashmasini assimilyatsiya qilish uchun quvur liniyasi diagrammasi.
2.11. PVD himoya qilish sxemasi.
2.12. Turbina blokining asosiy bug 'trubkasi diagrammasi.
2.13. Turbina blokining drenaj diagrammasi.
2.14. TVF-120-2 generatorining gaz-moy tizimining diagrammasi.
2.15. PT-80/100-130/13 LMZ quvur blokining energiya xususiyatlari.

Bilim testi

Matn va grafik materialni o'rgangach, talaba o'z-o'zini tekshirish dasturini ishga tushirishi mumkin. Dastur o'quv materialini o'zlashtirish darajasini tekshiradigan testdir. Noto'g'ri javob bo'lsa, operator xato xabari va to'g'ri javobni o'z ichiga olgan ko'rsatma matnidan iqtibos oladi. Ushbu kurs bo'yicha jami savollar soni 300 ta.

Imtihon

O'quv kursini tugatgandan va bilimlarni o'z-o'zini sinab ko'rgandan so'ng, talaba imtihon testini topshiradi. U o'z-o'zini tekshirish uchun taqdim etilgan savollar orasidan tasodifiy avtomatik tanlangan 10 ta savolni o'z ichiga oladi. Imtihon vaqtida imtihon oluvchidan bu savollarga hech qanday taklifsiz yoki darslikka murojaat qilish imkoniyatisiz javob berish so‘raladi. Sinov tugaguniga qadar xato xabarlari ko'rsatilmaydi. Imtihonni tugatgandan so'ng, talaba taklif qilingan savollar, imtihon oluvchi tomonidan tanlangan javob variantlari va noto'g'ri javoblar bo'yicha sharhlar bayon etilgan protokolni oladi. Imtihon avtomatik ravishda baholanadi. Sinov protokoli kompyuterning qattiq diskida saqlanadi. Uni printerda chop etish mumkin.

PT-80/100-130/13 isitish bug‘ turbinasi sanoat va isitish bug‘ini chiqarishga ega TVF-120-2 elektr generatorini 50 rp/s aylanish tezligi bilan to‘g‘ridan-to‘g‘ri haydash va ishlab chiqarish va isitish ehtiyojlari uchun issiqlik chiqarish uchun mo‘ljallangan.

Turbinaning asosiy parametrlarining nominal qiymatlari quyida keltirilgan.

Quvvat, MVt

nominal 80

maksimal 100

Steam reytinglari

bosim, MPa 12,8

harorat, 0 C 555

Chiqarilgan bug'ning ishlab chiqarish ehtiyojlari uchun sarflanishi, t/s

nominal 185

maksimal 300

Regulyatsiya qilingan isitish chiqishidagi bug 'bosimining o'zgarishi chegaralari, MPa

yuqori 0,049-0,245

pastroq 0,029-0,098

Ishlab chiqarishni tanlash bosimi 1.28

Suv harorati, 0 C

to'yimli 249

sovutish 20

Sovutish suvi sarfi, t/soat 8000

Turbinada quyidagi sozlanishi bug 'chiqarishlari mavjud:

mutlaq bosim (1,275 0,29) MPa va ikkita isitish ekstraktsiyasi bilan ishlab chiqarish - 0,049-0,245 MPa oralig'ida mutlaq bosim bilan yuqori va 0,029-0,098 MPa oralig'ida bosim bilan pastki. Isitishning qon ketishining bosimi yuqori isitish xonasiga o'rnatilgan bitta boshqaruv diafragmasi yordamida tartibga solinadi. Isitish rozetkalarida tartibga solinadigan bosim saqlanadi: yuqori rozetkada - ikkala isitish rozetkasi yoqilganda, pastki rozetkada - bitta pastki isitish rozetkasi yoqilganda. Tarmoq suvi quyi va yuqori isitish bosqichlarining tarmoq isitgichlari orqali ketma-ket va teng miqdorda o'tkazilishi kerak. Tarmoqli isitgichlardan o'tadigan suv oqimi nazorat qilinishi kerak.

Turbina bitta valli ikki silindrli blokdir. HPC ning oqim qismida bitta lasan nazorat bosqichi va 16 bosim darajasi mavjud.

LPC ning oqim qismi uch qismdan iborat:

birinchi (yuqori isitish rozetkasiga qadar) nazorat bosqichiga va 7 bosim darajasiga ega,

ikkinchi (isitish ekstraktsiyalari o'rtasida) ikki bosim bosqichi,

uchinchisi - tartibga solish bosqichi va ikkita bosim bosqichi.

Yuqori bosimli rotor qattiq zarb qilingan. Past bosimli rotorning dastlabki o'nta disklari mil bilan yaxlit tarzda zarb qilingan, qolgan uchta disk o'rnatilgan.

Turbinaning bug 'taqsimlanishi nozuldir. HPC dan chiqishda bug'ning bir qismi boshqariladigan ishlab chiqarish ekstraktsiyasiga ketadi, qolgan qismi LPC ga yuboriladi. Isitish ekstraktsiyalari tegishli LPC kameralaridan amalga oshiriladi.

Issiqlik vaqtini qisqartirish va ishga tushirish sharoitlarini yaxshilash uchun gardishlar va tirgaklarni bug 'isitish va HPC old muhriga jonli bug' etkazib berish ta'minlanadi.

Turbina turbina blokining mil chizig'ini 3,4 rpm chastotada aylantiruvchi milni aylantirish moslamasi bilan jihozlangan.

Turbinali pichoq apparati 50 Hz tarmoq chastotasida ishlashga mo'ljallangan, bu turbina blokining rotor tezligi 50 rpm (3000 rpm) ga to'g'ri keladi. Turbinaning uzoq muddatli ishlashiga 49,0-50,5 Gts tarmoq chastotasi og'ishi bilan ruxsat beriladi.

Past bosimli rotorning dastlabki o'nta disklari mil bilan yaxlit tarzda zarb qilingan, qolgan uchta disk o'rnatilgan.

HPC va LPC rotorlari rotorlar bilan yaxlit tarzda soxtalashtirilgan flaneslar yordamida bir-biriga qattiq bog'langan. LPC va TVF-120-2 tipidagi generatorning rotorlari qattiq mufta bilan bog'langan.

Turbinaning bug 'taqsimlanishi nozuldir. Yangi bug 'avtomatik qopqoq joylashgan alohida nozul qutisiga beriladi, u erdan bug' aylanma quvurlar orqali turbinani boshqarish klapanlariga oqadi.

HPC dan chiqqandan so'ng bug'ning bir qismi boshqariladigan ishlab chiqarish ekstraktsiyasiga o'tadi, qolgan qismi LPC ga yuboriladi.

Isitish ekstraktsiyalari tegishli LPC kameralaridan amalga oshiriladi.

Turbinani mahkamlash nuqtasi generator tomonidagi turbina ramkasida joylashgan va blok oldingi podshipnik tomon kengayadi.

Issiqlik vaqtini qisqartirish va ishga tushirish sharoitlarini yaxshilash uchun gardishlar va tirgaklarni bug 'isitish va HPC old muhriga jonli bug' etkazib berish ta'minlanadi.

Turbinada agregatning mil chizig'ini 0,0067 chastota bilan aylantiruvchi milni burish moslamasi o'rnatilgan.

Turbinali pichoq apparati 50 Hz tarmoq chastotasida ishlash uchun mo'ljallangan va sozlangan, bu rotorning 50 aylanishiga to'g'ri keladi. Turbinaning uzoq muddatli ishlashiga 49 dan 50,5 Gts gacha bo'lgan tarmoq chastotasida ruxsat beriladi.

Turbina bloki poydevorining balandligi kondensatsiya xonasining pol sathidan turbina xonasining pol sathigacha bo'lgan balandligi 8 m.

2.1 PT-80/100-130/13 turbinasining issiqlik sxemasining tavsifi

Kondensatsiya qurilmasi kondensator guruhini, havoni olib tashlash moslamasini, kondensat va aylanma nasoslarni, sirkulyatsiya tizimining ejektorini, suv filtrlarini va kerakli armatura bilan quvurlarni o'z ichiga oladi.

Kondensatorlar guruhi umumiy sovutish yuzasi 3000 m² bo'lgan o'rnatilgan bankli bitta kondanserdan iborat bo'lib, unga kiradigan bug'ni kondensatsiya qilish, turbinaning egzoz trubkasida vakuum yaratish va kondensatni saqlash uchun mo'ljallangan. o'rnatilgan to'plamdagi bo'yanish suvini isitish uchun termal jadvalga muvofiq ish rejimlarida kondensatorga kiradigan bug'ning issiqligidan foydalaning.

Kondensatorda bug 'qismiga o'rnatilgan maxsus kamera mavjud bo'lib, unda HDPE №1 uchastkasi o'rnatiladi. Qolgan HDPElar alohida guruh tomonidan o'rnatiladi.

Qayta tiklanadigan qurilma suvni tartibga solinmagan turbinali chiqish joylaridan olingan bug 'bilan isitish uchun mo'ljallangan va to'rt bosqichli LPH, uch bosqichli HPH va deaeratorga ega. Barcha isitgichlar sirt turidir.

HPH № 5,6 va 7 vertikal konstruksiyaga ega, o'rnatilgan desuperheaters va drenaj sovutgichlari. HHSlar suvning kirish va chiqishidagi avtomatik chiqish va nazorat klapanlaridan, elektromagnitli avtomatik valfdan, isitgichlarni ishga tushirish va o'chirish uchun quvur liniyasidan iborat guruh himoyasi bilan jihozlangan.

HDPE va HDPE (HDPE No 1 dan tashqari) elektron regulyatorlar tomonidan boshqariladigan kondensatni olib tashlash uchun nazorat klapanlari bilan jihozlangan.

Isitgichlardan isitish bug 'kondensatini to'kish kaskaddir. HDPE No 2 dan kondensat drenaj pompasi bilan chiqariladi.

Isitish tarmog'idagi suv uchun o'rnatish ikkita tarmoqli isitgich, kondensat va tarmoq nasoslarini o'z ichiga oladi. Har bir isitgich gorizontal bug '-suv issiqlik almashinuvchisi bo'lib, 1300 m² issiqlik almashinuvi yuzasiga ega bo'lib, u to'g'ridan-to'g'ri guruch quvurlaridan hosil bo'lib, quvur plitalarida ikki tomondan yondiriladi.

3 Stansiyaning issiqlik sxemasi uchun yordamchi uskunalarni tanlash

3.1 Turbina bilan ta'minlangan uskunalar

Chunki Kondensator, asosiy ejektor, past va yuqori bosimli isitgichlar turbina bilan birga loyihalashtirilgan stantsiyaga etkazib beriladi, keyin stansiyaga o'rnatish uchun quyidagilar qo'llaniladi:

a) 80-KTSST-1 tipidagi kondensator uch dona, har bir turbina uchun bittadan;

b) EP-3-700-1 tipidagi asosiy ejektor olti dona, har bir turbina uchun ikkitadan;

v) PN-130-16-10-II (PND No 2) va PN-200-16-4-I (PND No 3,4) tipidagi past bosimli isitgichlar;

d) PV-450-230-25 (PVD No 1), PV-450-230-35 (PVD No 2) va PV-450-230-50 (PVD No 3) turdagi yuqori bosimli isitgichlar.

Ko'rsatilgan uskunaning xarakteristikalari 2, 3, 4, 5-jadvallarda jamlangan.

2-jadval - kondansatör xarakteristikalari

3-jadval - asosiy kondanser ejektorining xarakteristikalari


Kurs loyihasi topshirig'i

3

1.

Dastlabki ma'lumotnoma ma'lumotlari

4

2.

Qozonni o'rnatishni hisoblash

6

3.

Turbinada bug'ni kengaytirish jarayonini qurish

8

4.

Bug 'va ozuqa suvining muvozanati

9

5.

PTS elementlari bilan bug ', ozuqa suvi va kondensat parametrlarini aniqlash

11

6.

PTS bo'limlari va elementlari uchun issiqlik balansi tenglamalarini tuzish va yechish

15

7.

Energiya quvvat tenglamasi va uning yechimi

23

8.

Hisobni tekshirish

24

9.

Energiya ko'rsatkichlarini aniqlash

25

10.

Yordamchi uskunalarni tanlash

26

Ma'lumotnomalar

27

Kurs loyihasi topshirig'i
Talabaga: Unichin D.M..

Loyiha mavzusi: STU PT-80/100-130/13 issiqlik sxemasini hisoblash
Loyiha ma'lumotlari

P 0 =130 kg/sm 2;

;

;

Q t =220 MVt;

;

.

Tartibga solinmagan ekstraktsiyalarda bosim - mos yozuvlar ma'lumotlaridan.

Qo'shimcha suvni tayyorlash - "D-1,2" atmosfera deaeratoridan.
Hisoblash qismining hajmi


  1. Nominal quvvat uchun SI tizimida STUni loyihalash.

  2. Texnik ta'lim muassasasining energiya samaradorligi ko'rsatkichlarini aniqlash.

  3. Kasbiy ta'lim muassasasining yordamchi uskunalarini tanlash.

1. Dastlabki ma'lumotnoma ma'lumotlari
PT-80/100-130 turbinasining asosiy ko'rsatkichlari.

1-jadval.


Parametr

Kattalik

Hajmi

Nominal quvvat

80

MVt

Maksimal quvvat

100

MVt

Dastlabki bosim

23,5

MPa

Dastlabki harorat

540

BILAN

Markaziy venoz nasosning chiqishidagi bosim

4,07

MPa

HPC chiqish joyidagi harorat

300

BILAN

Haddan tashqari qizdirilgan bug 'harorati

540

BILAN

Sovutish suvi oqimi

28000

m 3 / soat

Sovutish suvi harorati

20

BILAN

Kondensator bosimi

0,0044

MPa

Turbinada past bosimli isitgichlarda, deaeratorda, yuqori bosimli isitgichlarda ozuqa suvini isitish va asosiy besleme nasosining harakatlantiruvchi turbinasini quvvatlantirish uchun mo'ljallangan 8 ta tartibga solinmagan bug' chiqarish mavjud. Turbo haydovchidan chiqadigan bug 'turbinaga qaytadi.
2-jadval.


Tanlash

Bosim, MPa

Harorat, 0 C

I

PVD № 7

4,41

420

II

PVD № 6

2,55

348

III

HDPE № 5

1,27

265

Deaerator

1,27

265

IV

HDPE № 4

0,39

160

V

HDPE № 3

0,0981

-

VI

HDPE № 2

0,033

-

VII

HDPE № 1

0,003

-

Turbinada tarmoq suvini bir va ikki bosqichli isitish uchun mo'ljallangan, yuqori va pastki ikkita isitish bug 'chiqarish mavjud. Isitish ekstraktlari quyidagi bosimni nazorat qilish chegaralariga ega:

Yuqori 0,5-2,5 kg / sm 2;

Pastroq 0,3-1 kg / sm2.

2. Qozonni o'rnatishni hisoblash

VB - yuqori qozon;

NB - pastki qozon;

Qaytish - tarmoq suvini qaytarish.

D VB, D NB - navbati bilan yuqori va pastki qozon uchun bug 'iste'moli.

Harorat grafigi: t pr / t o br =130 / 70 C;

T pr = 130 0 C (403 K);

T arr = 70 0 C (343 K).

Markaziy issiqlik qazib olishda bug' parametrlarini aniqlash

VSP va NSP da bir xil isitishni faraz qilaylik;

Tarmoqli isitgichlarda kam isitish qiymatini qabul qilamiz
.

Quvurlardagi bosim yo'qotishlarini qabul qilamiz
.

VSP va NSP uchun turbinadan yuqori va pastki ekstraktsiya bosimi:

bar;

bar.
h WB =418,77 kJ/kg

h NB =355,82 kJ/kg

D WB (h 5 - h WB /)=K W SH (h WB - h NB) →

→ D WB =1,01∙870,18(418,77-355,82)/(2552,5-448,76)=26,3 kg/s

D NB h 6 + D WB h WB / +K W NE h OBR = KW NE h NB +(D WB +D NB) h NB / →

→ D NB =/(2492-384,88)=25,34 kg/s

D VB +D NB =D B =26,3+25,34=51,64 kg/s

3. Turbinada bug'ning kengayish jarayonini qurish
Tsilindrlarning bug 'tarqatish moslamalarida bosimning yo'qolishini taxmin qilaylik:

;

;

;

Bunday holda, silindrlarga kirishdagi bosim (nazorat klapanlari orqasida) bo'ladi:

h,s diagrammasidagi jarayon rasmda ko'rsatilgan. 2.

4. Bug 'va ozuqa suvining balansi.


  • Biz taxmin qilamizki, eng yuqori potentsialli bug 'so'nggi muhrlarga (D KU) va bug' ejektorlariga (D EP) boradi.

  • Oxirgi qistirmalardan va ejektorlardan sarflangan bug 'plomba qutisi isitgichiga yo'naltiriladi. Undagi kondensatni isitishni qabul qilamiz:


  • Ejektor sovutgichlaridagi chiqindi bug 'ejektor isitgichiga (EH) yo'naltiriladi. Unda isitish:


  • Turbinaga bug 'oqimi (D) ma'lum qiymat deb faraz qilamiz.

  • Ishchi suyuqlikning stansiya ichidagi yo'qotishlari: D U =0,02D.

  • Oxirgi muhrlar uchun bug 'iste'molining 0,5% ni olamiz: D KU =0,005D.

  • Faraz qilaylik, asosiy ejektorlar uchun bug‘ sarfi 0,3%: D EJ =0,003D.

Keyin:


  • Qozondan bug 'iste'moli quyidagicha bo'ladi:
D K = D + D UT + D KU + D EJ =(1+0,02+0,005+0,003)D=1,028D

  • Chunki Agar qozon tamburli qozon bo'lsa, unda qozonni tozalashni hisobga olish kerak.
Portlash 1,5% ni tashkil qiladi, ya'ni.

D davomi = 0,015D = 1,03D K = 0,0154D.


  • Qozonga beriladigan ozuqa suvi miqdori:
D PV = D K + D davomi = 1,0434D

  • Qo'shimcha suv miqdori:
D ext =D ut +(1-K pr)D pr +D v.r.

Ishlab chiqarish uchun kondensat yo'qotishlari:

(1-K pr)D pr =(1-0,6)∙75=30 kg/s.

Qozon barabanidagi bosim turbinadagi yangi bug 'bosimidan (gidravlik yo'qotishlar tufayli) taxminan 20% ko'proq, ya'ni.

P k.v. =1,2P 0 =1,2∙12,8=15,36 MPa →
kJ/kg.

Uzluksiz shamollash kengaytirgichidagi (CPD) bosim deaeratorga (D-6) qaraganda taxminan 10% yuqori, ya'ni.

P RNP =1,1P d =1,1∙5,88=6,5 bar →


kJ/kg;

kJ/kg;

kJ/kg;

D P.R.=b∙D davomi =0,438∙0,0154D=0,0067D;

D V.R. =(1-b)D davomi =(1-0,438)0,0154D=0,00865D.
D ext =D ut +(1-K pr)D pr +D v.r. =0,02D+30+0,00865D=0,02865D+30.

Tarmoqli isitgichlar orqali tarmoq suvining oqimini aniqlaymiz:

Isitish tizimidagi qochqinlarni aylanma suv miqdorining 1% miqdorida qabul qilamiz.

Shunday qilib, zarur kimyoviy mahsuldorlik. suvni tozalash:

5. PTS elementlari asosida bug ', ozuqa suvi va kondensat parametrlarini aniqlash.
Biz turbinadan regenerativ tizimning isitgichlariga bug 'quvurlaridagi bosimning yo'qolishini quyidagi miqdorda qabul qilamiz:


tanlayman

PVD-7

4%

II tanlov

PVD-6

5%

III tanlov

PVD-5

6%

IV tanlov

PVD-4

7%

V tanlash

PND-3

8%

VI tanlov

PND-2

9%

VII tanlov

PND-1

10%

Parametrlarni aniqlash isitgichlarning dizayniga bog'liq ( rasmga qarang. 3). Hisoblangan sxemada barcha HDPE va PVD sirtdir.

Asosiy kondensat va ozuqa suvi kondensatordan qozonga oqib o'tishi bilan biz kerakli parametrlarni aniqlaymiz.

5.1. Biz kondensat nasosidagi entalpiyaning o'sishini e'tiborsiz qoldiramiz. Keyin ED oldidagi kondensatning parametrlari:

0,04 bar,
29°C,
121,41 kJ/kg.

5.2. Ejektorli isitgichdagi asosiy kondensatning isishi 5 ° S ga teng deb hisoblaymiz.

34 °C; kJ/kg.

5.3. Bezli isitgichda (SP) suvni isitishni 5 ° S ga olamiz.

39 °C,
kJ/kg.

5.4. PND-1 - o'chirilgan.

VI tanlovidan bug 'bilan oziqlanadi.

69,12 °C,
289,31 kJ / kg = h d2 (HDPE-2 dan drenaj).

°S,
4,19∙64,12=268,66 kJ/kg

V tanlovidan bug 'bilan oziqlanadi.

Isitgich korpusidagi isitish bug'ining bosimi:

96,7 °C,
405,21 kJ/kg;

Isitgich orqasidagi suv parametrlari:

°S,
4,19∙91,7=384,22 kJ/kg.

Biz LPH-3 oldidagi oqimlarning aralashishi tufayli haroratning oshishini oldindan belgilab qo'ydik
, ya'ni. bizda ... bor:

IV tanlovdan bug 'bilan oziqlanadi.

Isitgich korpusidagi isitish bug'ining bosimi:

140,12°S,
589,4 kJ/kg;

Isitgich orqasidagi suv parametrlari:

°S,
4,19∙135,12=516,15 kJ/kg.

Drenaj sovutgichidagi isitish moslamasining parametrlari:

5.8. Oziqlantiruvchi suv deaeratori.

Oziqlantiruvchi suv deaeratori korpusdagi doimiy bug 'bosimida ishlaydi

R D-6 =5,88 bar → t D-6 N =158 ˚S, h’ D-6 =667 kJ/kg, h” D-6 =2755,54 kJ/kg,

5.9. Oziqlantiruvchi nasos.

Keling, nasosning samaradorligini olaylik
0,72.

Chiqarish bosimi: MPa. °C va drenaj sovutgichidagi isitish muhitining parametrlari:
Bug 'sovutgichdagi bug' parametrlari:

°C;
2833,36 kJ/kg.

Biz OP-7da isitishni 17,5 ° S ga qo'ydik. Keyin PVD-7 orqasidagi suv harorati ° C ga teng va drenaj sovutgichidagi isitish muhitining parametrlari:

°C;
1032,9 kJ/kg.

PPH-7 dan keyin besleme suvining bosimi:

Isitgichning o'zi orqasidagi suv parametrlari.