Duct fans for round ducts VKK. Duct fans for round ducts VKK Assembly and main elements
![Duct fans for round ducts VKK. Duct fans for round ducts VKK Assembly and main elements](/uploads/97a999799a698dc9bbc3ce885bf73e08.jpg)
No. Vent. d315
Fan type Duct
Email Engine. power, kWt 0,072
Productivity, max. cubic meters/hour 2200
Delivery to any city in the Russian Federation through TC
Technical and operational characteristics
Parameter | Magnitude | Unit | |
---|---|---|---|
Voltage | |||
Current | |||
Current frequency | |||
Power consumption | |||
Maximum air flow | |||
Sound pressure level at distance 3m | |||
Rotation frequency | |||
Maximum temperature of transported air | |||
Protection | |||
Weight | |||
Nozzle size | |||
Low noise performance |
Performance chart of VKMts 315
![](https://i1.wp.com/ventopt.ru/images/fancoil_kanal/2.png)
Overall dimensions of duct fan 315 mm
![](https://i1.wp.com/ventopt.ru/images/vkmc_schema.gif)
Dimensions | ØD | B1 | ØD1 | B | L | L1 | L2 | L3 |
---|---|---|---|---|---|---|---|---|
mm | 313 | 450 | 402 | 410 | 308 | 33 | 55 | 40 |
315 mm duct fan is a productive and reliable equipment designed for installation in supply and exhaust ventilation systems. The device parameters make it possible to effectively service large and medium-sized commercial, industrial and domestic premises.
Duct fan 315 (VK) is manufactured in metal and plastic versions and can be installed horizontally or vertically.
Round duct fan 315 can have several designs. In addition to the standard version, manufacturing plants also offer a silent version, high- and low-power engines, and models with lower energy consumption. The price for such modifications is slightly higher compared to standard samples.
Electric motor in duct fans and thermal protection
The centrifugal fan is equipped with a single-phase motor. The equipment is designed for connection to standard voltage networks. The design of the working element contributes to increased device performance. So the VKK wheel is equipped with backward-curved blades.
One of the undeniable advantages of the products is absolute safety during operation. The engines of all models are equipped with built-in thermal protection, which leads to shutdown when the maximum permissible temperatures are reached. After the threat has passed, the main elements have cooled down and are ready for further use, the devices automatically restart.
The design of electric motors involves the use of rolling bearings. These parts significantly increase the number of cycles of equipment use, increasing its service life to more than 40 thousand hours.
The devices are designed for continuous operation, so regularly restarting them can lead to premature wear of the working elements.
VKK electric motors have a degree of protection IP 44. This means that they are protected from splashes of water and small solid particles entering with the air.
Manufacturing plants produce several modifications of electric motors for this type of equipment. Each variety has its own label:
Other symbols in the model names may indicate the type of speed control and equipment.
Fans of this size are capable of serving larger areas compared to smaller diameter units such as the Tube 250 XL. You can buy equipment not only for use in city apartments and country cottages, but also for installation in restaurants, shops, warehouse office and industrial premises.
Assembly and main elements
The exhaust fan consists directly of the housing and the main working element. The shell can be made of galvanized steel or high-quality plastic.
The balanced engine wheel is equipped with curved blades. This feature allows the devices to achieve maximum safety and quietness with increased performance. The motor winding contains thermal contacts, which are the main components of the thermal protection system. Their reliability determines how promptly the device will stop working if it overheats.
The design of the models may differ significantly. Some products are equipped with a plug and power cord, a terminal box, and various types of fasteners and sensors.
An important component of the VK is the speed control system. Performance is set by controlling the incoming voltage. Devices may use transformers or seven-storage regulators.
Depending on the method of speed control, devices are divided into:
Several products can be connected to one regulator, but their total parameters should not exceed the nominal values of the element.
Installation and connection of fans for round ducts Vents VKMts
Installation of the Vents VKMts fan is permissible at any angle. Installing the fan at any angle does not affect its performance. The fan is mounted to a wall or any building structure using brackets.
The power connection occurs through the mounting box installed on the fan housing. The electrical connection diagram is available in the installation box and in the technical data sheet for the Vents VKMts fan.
Application
Universal devices can be installed on all types of surfaces inside and outside buildings. In cases where premises have special requirements in the field of noise characteristics, one or more noise suppressors can be added to the system, improving the fan’s performance at any part of the frequency range.
Duct fan 315, Analogs
Max. |
Voltage, |
Power |
Manufacturer |
Price, |
||
---|---|---|---|---|---|---|
1400 | 220 | Ostberg | 8900 |
|||
1620 | 220 | Ostberg | 10500 |
|||
1440 | 220 | Ostberg | ||||
1835 | 220 | Ostberg | ||||
2600 | 220 | 0,225 | Russia | |||
1700 | 220 | 0,320 | Russia | |||
2270 | 220 | 0,29 | Russia |
Round duct fans (VKK) are used in various supply and exhaust ventilation systems to move non-explosive air mixtures at temperatures from -15 to +60 °C. Installed directly into a round duct (air duct) vertically or horizontally. Duct fans for round ducts equipped with an impeller with backward curved blades, an electric motor with an external rotor, and built-in thermal contacts. Protection class of electric motors is IP44. Manufactured in accordance with TU 4861-006-03002146-2016.
Duct fans are produced in standard sizes corresponding to the internal diameters of round ventilation ducts: VKK-100, VKK-125, VKK-160, VKK-200, VKK-250, VKK-315, VKK-355, VKK-400, where the numbers indicate the internal diameter of the duct in mm.
Round duct fans are manufactured in four versions:
- in a plastic case (VKK)
- in a galvanized metal case, with mounting bracket (VKK-M)
terms of Use
Round duct fans VKK designed for moving non-explosive air and gas environments with temperatures from -40°C to +40°C, containing solid impurities of no more than 100 mg/m3, not containing sticky substances and fibrous materials, in temperate climate conditions of the 2nd category of placement according to GOST 15150 -69.
Overall and connection dimensions of VKK fans
Technical characteristics of round duct fans VKK and VKK-M ( motor-wheel standard)
Characteristic |
VKK-100 VKK-100M |
VKK-125 VKK-125M |
VKK-160 VKK-160M |
VKK-200 VKK-200M |
VKK-250 VKK-250M |
VKK-315 VKK-315M |
VKK-355M |
Voltage, V/Hz | ~230/50 | ||||||
Phasing | 1 | ||||||
Power consumption, kW | 0,08 | 0,08 | 0,09 | 0,14 | 0,14 | 0,23 | 0,21 |
Current, A | 0,3 | 0,3 | 0,38 | 0,6 | 0,6 | 1,05 | 0,93 |
Air capacity, max m3/h | 250 | 320 | 700 | 950 | 950 | 1800 | 2000 |
Rotation speed, rpm-1 | 2300 | 2300 | 2700 | 2650 | 2650 | 2700 | 1400 |
Maximum temperature moving air, °C |
60 | 50 | |||||
Thermal protection type | Automatic | ||||||
Weight, kg | 3,2 | 3,2 | 4,5 | 5,3 | 5,3 | 6,9 | 12 |
Speed controller type | SRM-500 |
Acoustic characteristics of round duct fans VKK
Standard size | dB(A) | Octave frequency bands, Hz | ||||||||
General | 63 | 125 | 250 | 500 | 1k | 2k | 4k | 8k | ||
VKK 100 | Lwa Channel | 71 | 57 | 60 | 69 | 65 | 59 | 55 | 48 | 41 |
Lwa to the environment | 55 | 39 | 41 | 42 | 48 | 52 | 47 | 37 | 30 | |
VKK 125 | Lwa Channel | 70 | 60 | 60 | 67 | 64 | 58 | 57 | 51 | 51 |
Lwa to the environment | 51 | 38 | 42 | 38 | 45 | 40 | 44 | 39 | 40 | |
VKK 160 | Lwa Channel | 74 | 52 | 60 | 67 | 71 | 65 | 62 | 60 | 50 |
Lwa to the environment | 59 | 29 | 38 | 37 | 56 | 55 | 49 | 47 | 37 | |
VKK 200 | Lwa Channel | 73 | 56 | 59 | 67 | 67 | 66 | 64 | 60 | 53 |
Lwa to the environment | 58 | 41 | 37 | 43 | 48 | 56 | 48 | 43 | 36 | |
VKK 250 | Lwa Channel | 74 | 54 | 60 | 67 | 66 | 67 | 67 | 63 | 55 |
Lwa to the environment | 53 | 39 | 32 | 35 | 46 | 49 | 48 | 43 | 32 | |
VKK 315 | Lwa Channel | 77 | 56 | 59 | 67 | 67 | 71 | 72 | 68 | 66 |
Lwa to the environment | 56 | 35 | 24 | 34 | 43 | 50 | 53 | 48 | 41 | |
VKK 355 | Lwa Channel | 80 | 56 | 69 | 70 | 75 | 74 | 72 | 70 | 68 |
Lwa to the exit | 83 | 57 | 69 | 69 | 76 | 77 | 78 | 72 | 66 | |
Lwa to the environment | 60 | 32 | 32 | 39 | 59 | 49 | 48 | 49 | 40 |
Aerodynamic characteristics of VKK and VKK-P fans
Diameters 100, 125, 160 Diameters 200, 250 Diameters 315, 355 Diameter 400
To reduce losses associated with air flow turbulence, straight sections of air duct should be located at the inlet and outlet of the fan.
The minimum recommended length for these straight runs is one fan diameter on the inlet side and three fan diameters on the outlet side.
The suction duct must not have any obstacles to the air flow (dampers, branches, etc.).
Electrical diagram for connecting round duct fans VKK
Duct fans for round ducts VKK St. Petersburg
- protection class IP44
- body made of galvanized steel
- backward curved shoulder blades
- easy to install, install, connect
Fan model | Maximum productivity, m3/hour | Statistical pressure, Pa | Rotation speed, rpm | Power consumption, W | price, rub. | |
VKK-100 | 230 | 310 | 2640 | 65 |
3400 | |
VKK-125 | 340 | 300 | 2630 | 67 |
3500 | |
VKK-160 | 690 | 350 | 2510 | 104 | 3950 | |
VKK-200 | 960 | 530 | 2530 | 150 | 4860 | |
VKK-250 | 1100 | 550 | 2610 | 150 | 4900 | |
VKK-315 | 1450 | 650 |
2620 | 205 |
6600 |
The Teplomash St. Petersburg plant supplies inexpensive duct fans for round air ducts of various diameters, which are used in stacked ventilation systems.
Technical features of round duct fans
A round duct fan is a budget solution for ventilation for any purpose. Duct fans are ideal for a country house, apartment, restaurant, fitness center, warehouse, workshop, garage, etc.
The fan casing made of galvanized steel houses an external rotor motor on which an impeller is installed. The round fan is mounted to the wall using a bracket (included in delivery). The fan is mounted in an air duct system of a certain diameter. You can buy a VKK duct fan for air ducts 100 mm, 125 mm, 160 mm, 250 mm, 315 mm in St. Petersburg.
Duct fans for round air ducts from Teplomash have a number of advantages:
- compact sizes;
- stable performance;
- ease of installation in any position;
- reliability and durability of operation.
Advantageous offers from the manufacturer
The most affordable prices for the VKK 200 fan are offered by Teplomash. Our fans are suitable for equipping industrial and civil facilities.
To order a round duct fan VKK 100, 125, 160, 200, 250, 315 mm, please contact our company managers.
Fans VKK-315 are used in various supply and exhaust ventilation systems to move non-explosive air mixtures with temperatures up to +40 °C. Installed directly into a round duct with a diameter of 315 mm vertically or horizontally. Duct fans 315 mm equipped with a plastic or metal galvanized housing, a composite impeller with backward curved blades, an electric motor with an external rotor, thermal protection with automatic restart. As an option, they are equipped with flexible inserts, mounting brackets and speed controllers. Protection class of electric motors is IP44. The warranty period is 12 months.
Fans for 315 mm round ducts are available in six models :
Appearance | Designation models |
Frame | Manufacturer electric motor |
bracket included |
Voltage, IN |
Power engine, W |
Current, A |
Performance maximum, m 3 / h |
Level noise, dB |
Weight, kg |
Aerodynamic characteristics |
Plastic | Ebmpapst (Germany) |
No | 220 | 230 | 1,1 | 1750 | 53 | 7,5 | |||
![]() |
Galvanized metal |
China | Yes | 220 | 230 | 1,05 | 1800 | 56 | 6,9 | ||
![]() |
Galvanized metal |
Ebmpapst (Germany) |
Yes | 220 | 210 | 0,95 | 1400 | 50 | 7,5 | ||
![]() |
Galvanized metal |
Ebmpapst (Germany) |
Yes | 220 | 230 | 1,0 | 2100 | 54 | 7,5 | ||
![]() |
Galvanized metal |
Ebmpapst (Germany) |
Yes | 220 | 170 | 1,4 | 2300 | 7,5 | |||
![]() |
Galvanized metal |
Ebmpapst (Germany) |
No | 220 | 230 | 1,0 | 2100 | 54 | 7 |
terms of Use
Round duct fansare intended for moving non-explosive air and gas environments with temperatures from -40°C to +40°C, containing solid impurities of no more than 100 mg/m 3, not containing sticky substances and fibrous materials, in temperate climate conditions of the 2nd category of placement, according to GOST 15150-69.
In our production company you can buy duct fans with a diameter of 315 mm from stock and at the best price.
Overall and connection dimensions of fans VKK-315
![]() |
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||
|
|