Removing power from the firefighter shs vist 501. Installation and programming manual. Automated security and fire alarm system Pritok-A

Removing power from the firefighter shs vist 501. Installation and programming manual. Automated security and fire alarm system Pritok-A

The American security systems manufacturer Ademco was founded in 1977 and almost immediately became a world leader in the production of innovation systems burglar alarm. One of the main directions of the company was the production of high-tech Vista control boards/devices.

Vista control panels (Vista 101 and Vista 501) are designed to implement a security and fire alarm system alarm system as on objects individuals: apartments, country houses and townhouses, and at organizational sites: security of offices, warehouses, shops.

Vista control and control devices (VISTA) on Russian market security systems appeared in the late 1990s. Initially, the Vista security alarm system (Vista 101, 501) was intended for centralized security of premises with connection to the centralized surveillance consoles of the territorial police units of the Federal State Institution of the UVO of the Main Directorate of the Ministry of Internal Affairs of Russia in Moscow and the Moscow region. In accordance with the requirements of the Federal State Institution of the Higher Military District of the Main Directorate of the Ministry of Internal Affairs of Russia for Moscow and the Moscow Region security device was installed in conjunction with a control panel of the “Bastion” type, UO3K SPI “Phobos”, etc., which made it possible, using a crossed telephone line provide control of supply voltage from 48 to 60V. In the absence of this voltage (KTL), the security system generated an “Alarm” signal and the consoles of the FGKU UVO of the Main Directorate of the Ministry of Internal Affairs of Russia for Moscow and the Moscow Region sent police crews to the facility. Since the beginning of 2014, the MGTS company has been working to disconnect crossed lines, and therefore clients of the Federal State Institution of the Military District of the Main Directorate of the Ministry of Internal Affairs of Russia in Moscow and the Moscow region need to make a replacement control panels, installed in addition to the Vista control panel (Vista 101,501) on more modern OPs with the ability to transmit incident signals via GSM and Ethernet channels. More detailed information, as well as the cost of replacement, you can contact our managers by phone: 8-499-372-02-21, 8-495-648-80-08.

Currently, security equipment Vista 101, Vista 501 with additional modules or control panels are compatible with almost all remote controls as private ones security companies, and on centralized monitoring consoles of organizations in Moscow and the Moscow region.

1 User's manual for the VISTA-501 control panel with control panels (user keyboards) type 6139 and

2 Types of keyboards Determine what kind of keyboard you have. Two types of user keyboards (control panels) can be used with the system: “Alpha keyboards” type They have a two-line 32-character text display. “Fixed keypads” type Can display fixed labels and two-digit zone numbers.

3 Keyboard type Use in master keyboard mode. This keyboard can be used as a master keyboard when dividing the system into sections (areas). In this case, the display shows the status of all sections. SYSTEM STATUS ARN*ARNN SYSTEM STATUS ARN*ARNN The number indicates the partition number, and the letter below it indicates its status. Possible options indication of the partition status: N Not ready for protection (there are violated zones) S Partition in perimeter protection mode R Ready for protection M Partition in maximum protection mode A Armed (fully armed mode) I Partition in instantaneous protection mode * Alarm/fault in the partition B There are bypassed zones/ready to arm To view the status and control of a specific partition, you must press the [*] key and then the number of the desired partition, for example: [*]+ for the first partition. After going to the section, the display will show the status of the section: *** DISARMED *** READY TO ARM ***DISARMED*** READY TO ARM To return to the indication of the status of all sections (go to the master section), press [*]+. Also, if no key is pressed within two minutes, the keyboard will automatically return to the initial display. User codes and permissions. To control the system, you will need to enter personal user codes. Each user can be assigned his own level of authority, as well as determine the sections to which he will have access. The user code is four-digit, i.e. consists of four digits and can be anything in the range Each user code in the system has its own two-digit serial number in the range User levels and powers: Level User type Powers 1 Master code 2 Manager 3 Operator A 4 Operator B 5 Operator C 6 Duress code Can perform any actions in the assigned sections, and can also add, delete and change the codes of managers and operators. Master codes are entered by the installer. Can manage the system in assigned sections, and can also add, delete and change manager codes. Can manage the system in designated sections, but cannot add and delete codes of other users. Can control the system in designated sections, but cannot add or delete codes of other users, and also does not have access to bypass zones. Can arm assigned sections, can disarm assigned sections, but only if arming was carried out with the same code. Can arm/disarm the system while simultaneously sending an alarm message to the monitoring station.

4 Rules for entering and changing user codes and permissions: The user cannot change or delete a user code of the same or higher level of authority than him. A user can only add user codes with a level of authority lower than himself. User can be added New user English code only for those sections to which he himself has access. You can assign a user's authority level or the sections available to him only at the time of creating a new code. If you need to change the permissions of the code, the only way to do it is to delete the code and create it again. The user code can be changed or deleted only from the section in which it was created. The user code is always entered in two-digit format, users 2-9 are entered as User Code Entry. Before adding a user code on the master keyboard, you must go to one of the sections that will be assigned to the user by pressing the [*] key and then the number of the desired section. You can exit the Add User Code mode at any time by pressing the [*] or [#] key. Also, the code entry mode will exit automatically if you do not press any key for 10 seconds. To enter a code: 1. Enter the master code (or manager code). 2. Enter the two-digit new user number (02-75) 3. Enter the four-digit new user code. After this, the system will sequentially ask a series of questions regarding the new user and his powers. Depending on the system settings, some requests will not be issued. THIS IS NEW. BENEFITS? ADD A NEW USER? USER NUMBER = X12 ENTER LEVEL USER NUMBER = 12 ENTER AUTH. LEVEL OPEN/CLOSED REPORT? OPEN/CLOSE REPORT ENTER DISTANCE GR (0-8) ACESS GROUP? ENTER (0-8) This request will be displayed if a user with the same number already exists. “0” - The user code with this number (entered in step 2) will be replaced with a new one (entered in step 3), the keyboard will display a corresponding message and exit the code entry mode. “1” - A new user will be added and assigned the nearest available number. The keyboard will display the following prompt. Enter the user authority level: 1 Master code (entered only by the installer) 4 Operator B 2 Manager 5 Operator C 3 Operator A 6 Duress code This prompt will only appear if the code is added using the installer code. In other cases, the settings for sending messages about arming/disarming for a new code will be similar to the settings of the adding user. “0” reports on arming/disarming the security user are not sent to the central monitoring station. "1" reports are sent. This request will be displayed if groups for which the access schedule is valid were previously programmed. Enter the group number (1-8) to which the user will belong. Enter "0" if no user restriction is required.

5 RF BUTTON? RF BUTTON? RF BUTTON ZONE (01-64) ENTER BUTTON ZN#? (01-64) MULTIPLE ACCESS? MULTI ACCESS? SECTION 2 P2? PART - 2 P2? GLOBAL. TAKEOVER GLOBAL ARM? This request will be displayed if a 5800 series transmitter (key fob) has been programmed in the system for arming/disarming and it has not yet been assigned to the user. Enter "0" if you do not want to assign a transmitter to a user. Enter "1" to assign the transmitter to this user. This request will be displayed if the answer “1” was given to the system request at the previous step. Enter the zone number assigned to any of the buttons on the desired transmitter. Enter "1" if the user should have access to other parts of the system. Enter "0" if you only need access to one partition. The system will then exit user programming mode. If “1” was selected in the previous step, then questions about access to each of the existing sections will be asked sequentially, and you will also need to specify user permissions for the remaining sections. If the user has access to several sections (selected “1” in the previous step), a question will be asked about the possibility of global setting by the user. Enter “1” if several partitions will need to be armed/disarmed at the same time. Enter "0" if each partition should be armed/disarmed by the user sequentially. Upon completion of the code adding procedure, generalized information on the user’s properties will be displayed sequentially, for each section assigned to the user.

6 View user permissions. To view user permissions, you must enter a four-digit user code, and then press the “*” key 2 times. If the code is valid, information about the user's permissions and sections assigned to him will be displayed. The display order is the same as when you finish adding the user code. Changing user codes. To change the user code, you must go to the section in which the user was originally created (there is a “*” symbol when viewing permissions). Next, enter the master code, then “8”, the user number and four digits of the new code. For example, to change the code, user 05 to “4568” using the master code “1234” will need to enter: Next, the keyboard will ask you whether you want to add a new code or change the existing one: THIS IS NEW. BENEFITS? If you answer “1”, the system will go into the mode of adding codes. To change the code you must answer “0”. After which the display will show a message indicating a successful code change or an error. USER05Х CHANGED ERROR USER05ХХ ERROR-USER 05 NOT CHANGED NOT CHANGED An error message will be displayed if you try to change a user while not in the partition in which it was created. Deleting user codes. To delete a user code, you must go to the section in which the user was originally created (there is a “*” symbol when viewing permissions). Next, enter the master code, then “8”, the user number and the master code again. For example, to delete the code, user 05 using the master code “1234” will need to enter: Next, a request will be issued to delete the code: DELETE 05? ADD A NEW USER? To delete, you must answer “1”, after which a successful deletion will be reported: USER CODE. 05 DELETED USER 05 CHANGED SUCCESFULLY OK TO DELETE 05? USER CODE 05 DELETED The user code and all settings have been completely deleted from all sections. Possible error messages: ERROR USER 05 XX IS NOT DELETED ERROR-USER 05 NOT DELETED ERROR USER05 DOES NOT EXIST. ERROR-USER 05 DO NOT EXIST This message will be issued when you try to delete a user who has access to this section, but was created in another section. This message will be displayed when you try to delete a user who does not have access to this section.

7 Arming and disarming. If the keyboard operates in master keyboard mode, then to control a specific section you will need to go to this section by typing the command [*] + section number (1-8). If the partition is ready to arm, the green LED “Ready” will light up and the display will show: *** DISARMED *** READY TO ARM Otherwise, a message indicating that it is not ready to arm will be displayed: *** DISARMED *** VIOLATED ZONES *** DISARMED *** PRESS * TO VIEW To view violated zones, press the [*] key. After all zones are closed, the system can be armed. To arm fully, enter the code and press the key. After this, the red “Armed” indicator will light up and the countdown of the exit delay (if programmed) will begin, during which it is necessary to leave the protected premises. The display will show: *** ARMED *** YOU CAN EXIT At the end of the exit delay, the indication will change to: *** ARMED *** FULL ARMED ***DISARMED*** READY TO ARM ***DISARMED*** ZONES FAULTED * **DISARMED*** HIT * FOR FAULTS ARMED **AWAY** YOU MAY EXIT NOW ARMED **AWAY** Three additional security modes are also available: partial, maximum and instant. All modes are summarized in the table below: Command Security mode Features Code+ Full Main security mode. All sensors in the section are protected, there is an entry delay. Code+ Partial Perimeter Security. Only perimeter sensors protect the user; the user can remain indoors. Code+ Maximum Similar to full security, but there is no entry delay. Code+ Instant Similar to partial security, but there is no entry delay. To disarm the system, you must enter the code and press the key. The system will be disarmed and the red “Security” indicator will go out. If an alarm occurs during arming, the disarming command must be entered twice, i.e. "code" + + "code" + . After the first entry of “code”+, the system will be disarmed and the alarm will turn off; after the second, the alarm memory will be cleared. Bypass zones. If one of the sensors is faulty and prevents the system from being armed, it can be excluded for one security cycle using the zone bypass function. You can bypass one, several or all unfinished zones. To bypass a zone, dial “code”++ “zone number”. The zone number is entered in a two-digit format; you can enter several zone numbers at once. To bypass zone 4 with code 2458, you will need to enter: To bypass zones 2, 7, 19, 25 with the same code: To automatically bypass all unready zones, after entering the code and key, press [#]. To bypass all unready zones using code 2458, enter #.

8 A message about zone bypass will appear on the display; after arming and disarming the system, zone bypass will be canceled automatically. To cancel bypassing zones, dial “code”+. Generating an alarm from the keypad. In case of emergency, you can use the following keyboard functions. Duress code. If you are forced to disarm the system under threat of physical harm, then use the duress code instead of your code to disarm the system. Do all other steps as usual, but instead of the four digits of your code, enter the four digits of the duress code. The system will be disarmed as usual, but the corresponding alarm will be sent to the central station. alarm signal. Panic buttons. Three combinations of emergency buttons [*]+[#], +[*] and +[#], as well as three emergency buttons A, B, C can be programmed on the keyboard. To trigger an alarm, you must press and hold the corresponding pair of buttons or button for 2 seconds. Alarm functions are available only for systems connected to monitoring stations; in local systems they can only be used to activate sound alarm, for example in case of fire. Because correct use These keyboard functions can directly affect your life and health in a critical situation, check with your service provider in advance which of them are available on your system and how to use them correctly. Switch between sections. If the keyboard is assigned to one of the sections, then it will display the status of only its section. The command “code” + [*] + “section number (1-9)” will allow you to move on to managing other sections. If transition to the desired section is prohibited, a corresponding warning will be issued and the transition will not occur. After moving to the desired section, the keyboard will display the status of the current section and allow you to fully control it. To return to the section to which the keyboard is assigned, type “code” + [*] + . The keyboard will also return to its “own” section if no keyboard button is pressed within two minutes. Attention mode (door bell). The keypad can notify you when a door or window is opened with a sound signal (door bell mode). To enable or disable the door or window opening alert, enter the “code” + . The display will show the following notification: P. ATTENTION ON CHIME MODE ON P. ATTENTION OFF CHIME MODE OFF Built-in prompts. The keyboard has a built-in quick reference guide. To view it, press and hold for 5 seconds the button whose function you want to know a description of. After 5 seconds, a short text hint on the functions of this button will be displayed.

9 Quick reference to keyboard functions. Function Description Go to section (master keyboard) [*] +<номер раздела>Go to a section (if the keyboard is assigned to a section)<код пользователя > + [*] + <номер раздела>Full arming<код пользователя > <код пользователя >+ Disarming<код пользователя > <код пользователя> + + <код пользователя>+ Adding and changing user code<мастер код> + + <номер пользователя> + <новый код>, then - interactive menu Deleting a user code<мастер код> + + <номер пользователя> + <мастер код>, then confirm deletion Bypass zones<код пользователя> + + <номер зоны (2 цифры)>Fast zone bypass<код пользователя> <код пользователя >+ Before performing any actions, you must go to the desired section. This manual does not describe keyboard functions related to scheduling, access control and event log, because they are used extremely rarely in practice and are described in full instructions on the Vista-501 panel.

10 Keyboard type Displayed information. This keypad is equipped with a two-digit digital display and a set of fixed messages that are displayed as needed. There are also two additional LEDs, green “READY” and red “ARMED,” which allow you to quickly assess the state of the system. 03 FULL OCR NO VOLTAGE PARTIAL. ARMED ATTENTION INSTANTLY BATTERY ALARM UNARMED CHECK FIRE NOT READY 03 AWAY NO AC STAY CHIME INSTANT BAT ALARM BYPASS CHECK FIRE NOT READY Indicator Indicates The number indicates the zone number, in addition with the zone number Number (03) the inscription “ALARM”, “CHECK” can be displayed "", "FIRE", "UNARMED", "BATTERY" - showing the corresponding zone status. ALARM System is in alarm state CHECK Trouble in zone FIRE Fire alarm in system FULL. AWAY The system is fully armed PARTIALLY. SECURITY (STAY) System in partial security mode (perimeter) Security without entry delay simultaneously with the inscription INSTANT (INSTANT) “FULL SECURITY” - means maximum security mode, with the inscription “PARTIAL SECURITY” - instantaneous perimeter security mode. BYPASS There are one or more bypassed zones. VOLTAGES (AC) Normal presence indication mains power 220V. NO VOLTAGE (NO AC) Indication of loss of external 220V mains power. ATTENTION (CHIME) “Attention” mode is enabled ( door bell) BATTERY (BAT) The battery in the sensor/device is low READY (READY) The system is ready for arming (at the same time the green LED “READY” will also light up) NOT READY (NOT READY) The system is not ready for arming, to view the violated zones press the “*” key Arming and disarming. If the system is ready to arm, the green “Ready” LED will light up and the corresponding message will appear on the display. Otherwise, the display will show “NOT READY”. To view the violated zones, press the [*] key; the numbers of all not closed areas. After all zones are closed, the system can be armed. To arm fully, enter the code and press the key. After this, the red “Armed” indicator will light up and the countdown of the exit delay (if programmed) will begin, during which it is necessary to leave the protected premises. The display will show “FULL.” OHR" (AWAY).

11 Three additional security modes are also available: partial, maximum and instant. All modes are summarized in the table below: Command Security mode Features Code+ Full Main security mode. All sensors in the section are protected, there is an entry delay. Code+ Partial Perimeter Security. Only perimeter sensors protect the user; the user can remain indoors. Code+ Maximum Similar to full security, but there is no entry delay. Code+ Instant Similar to partial security, but there is no entry delay. To disarm the system, you must enter the code and press the key. The system will be disarmed and the red “Security” indicator will go out. If an alarm occurs during arming, the disarming command must be entered twice, i.e. "code" + + "code" + . After the first entry of “code” + the system will be disarmed and the alarm will turn off, after the second the alarm memory will be cleared. Bypass zones. If one of the sensors is faulty and prevents the system from being armed, it can be excluded for one security cycle using the zone bypass function. You can bypass one, several or all unfinished zones. To bypass a zone, dial “code”++ “zone number”. The zone number is entered in a two-digit format; you can enter several zone numbers at once. To bypass zone 4 with code 2458, you will need to enter: To bypass zones 2, 7, 19, 25 with the same code: To automatically bypass all unready zones, after entering the code and key, press [#]. To bypass all unready zones using code 2458, enter #. If there are bypassed zones, the message “BYPASS” will be displayed on the display; after arming and disarming the system, bypassed zones will be unarmed automatically. To cancel bypassing zones, dial “code”+. Generating an alarm from the keypad. In case of emergency, you can use the following keyboard functions. Duress code. If you are forced to disarm the system under threat of physical harm, then use the duress code instead of your code to disarm the system. Do all other steps as usual, but instead of the four digits of your code, enter the four digits of the duress code. The system will be disarmed as usual, but a corresponding alarm will be sent to the central station. Panic buttons. Three combinations of emergency buttons [*]+[#], +[*] and +[#] can be programmed on the keypad. To trigger an alarm, you must press and hold the corresponding pair of buttons for 2 seconds. The alarm functions are available only for systems connected to monitoring stations; in local systems they can only be used to activate an audible alarm, for example in case of fire. Since proper use of these keyboard functions can directly affect your life and health in a critical situation, check with your service provider in advance which of them are available on your system and how to use them correctly.

12 “Attention” mode (door bell). The keypad can notify you when a door or window is opened with a sound signal (door bell mode). To enable or disable the door or window opening alert, enter the “code” + . Activation of the mode is indicated by the inclusion of a corresponding message on the keyboard. Switch between sections. Even if the system is divided into several sections (areas), the keyboard displays the status of only one section, to which it is assigned by the installer and allows you to control only that. The command “code” + [*] + “section number (1-8)” will allow you to move on to managing other sections. If the transition to the desired section has taken place, the message “C0” will be briefly displayed. After moving to the desired section, the keyboard will display the status of the current section and allow you to fully control it. To return to the section to which the keyboard is assigned, type “code” + [*] + . The keyboard will also return to its “own” section if no keyboard button is pressed within two minutes. Editing user codes. It is strongly recommended to edit user codes using a keyboard like However, if there is only one partition in the system, then editing codes can be done from the keyboard. You can exit the user code editing mode at any time by pressing the [*] or [#] key . Also, the code editing mode will exit automatically if you do not press any key for 10 seconds. Levels and powers of users: Level User type Permissions 1 Master code 2 Manager 3 Operator A 4 Operator B 5 Operator C 6 Duress code Can perform any actions in the assigned sections, and can also add, delete and change codes of managers and operators. Master codes are entered by the installer. Can manage the system in assigned sections, and can also add, delete and change manager codes. Can manage the system in designated sections, but cannot add and delete codes of other users. Can control the system in designated sections, but cannot add or delete codes of other users, and also does not have access to bypass zones. Can arm assigned sections, can disarm assigned sections, but only if arming was carried out with the same code. Can arm/disarm the system while simultaneously sending an alarm message to the monitoring station. Rules for entering and changing user codes and permissions: The user cannot change or delete a user code of the same or higher level of authority than him. A user can only add user codes with a level of authority lower than himself. The user code is always entered in a two-digit format, users 2-9 are entered as To enter or change the code: 1. Enter the master code (or manager code). 2. Enter a two-digit user number (02-75) 3. Enter a four-digit new code.

13 4. If “Ad” is displayed on the display, then a user with that number already exists. Press “1” to replace the digits of the current user code with the numbers entered in step 3, at this point the process of changing the user code is completed and the keyboard will return to the standard display. Press “0” to add a new user, the system will automatically select the nearest available user number and assign the numbers to it when entered in the step. The message “EA” will appear on the display - enter the user’s authority level by pressing the corresponding number (2-6). The process of adding a user code is now complete and the keyboard will return to its standard display. To delete a user code: 1. Enter the master code (or manager code). 2. Enter the two-digit user number (02-75) 3. Enter the master code (or manager code). 4. The display will show the message “de”, press “1” after which the user code will be deleted and the keyboard will return to the standard display. A quick reference guide to keyboard functions. Function Description Full arming<код пользователя >+ Perimeter arming<код пользователя >+ Disarming<код пользователя >+ Disarming after an alarm<код пользователя> + + <код пользователя>+ Bypass zones<код пользователя> + + <номер зоны (2 цифры)>Fast zone bypass<код пользователя>+ + [#] all unready zones will be bypassed Alarm buttons from the keypad [*] + [#], + [*] and + [#] “Attention” mode on/off<код пользователя >+ Go to another section<код пользователя > + [*] + <номер раздела>

Security and fire system
"Vista-501B"

Installation Guide
and programming

Buzdalin I.A., Sarkisov A.Yu., Shilin A.Yu.

Security and fire system "Vista-501V". Installation and Programming Guide.

This book is the first of its kind. All reference materials that existed before this time were more or less successful translations of instructions for programming the system.

In this publication, an attempt was made not only to talk in detail about installation and programming security and fire system, but also logically present the material so that even a person who is encountering this system for the first time can cope with programming.

© JSC "MZEP-Okhrana" 2007

Preface 6

Part one.

Technical means of the fire and security system "Vista-501V"

1.1. General information about the Vista-501B system 9

1.2. Control panel 13

1.3. Wired control panels 15

User and installer control and display panel

Programmable 61391 16

User control and display panel 61281 24

1.4. Radial cables 28

1.5. Two-wire address line 33

Current amplifier of two-wire address line 42971 35

Addressable magnetic contact detector 49391 SN 38

Addressable magnetic contact detector 41911 SN 39

Expander for 8 zones 42081U 40

Expander for 2 zones 4190WH1 44

1.6. Technical means of radio channel 48

Radio receiver for monitoring radio channels

Zone 58811 50

Bidirectional radio control panel 58271BD 54

Transmitting module 5800TM1 56

Radio channel alarm detector 58021 58

Radio channel alarm detector 58021MN 59

Radio-channel four-button control panel 58041 60

Security detector two-zone radio channel 58161 62

Security detector for three zones, radio channel 58171 65

Volumetric optical-electronic security detector
radio channel 58901 68

1.7. Event recording devices 76

Serial interface module 41001 SM 76

Serial interface controller "KPI" 78

Programming event log printing 81

1.8. Technical means of remote warning 91

Relay module 42041 91

External sounder 702 97

Signal light 710 98

1.9. Backup power supply 100


    1. System testing 104
Part two.

Programming the Vista-501V security and fire system

2.1. System programming techniques 103

2.2. System programming technique 108

Programming PU 61391 109

Restoring factory settings 111

Programming system partitions 112

Programming the radio channel of system 114

Programming zones 117

Programming Announcers 118

User programming 121

Programming schedules 127

2.3. Programming in menu #93 139

Programming zones 140

Programming serial numbers 145

Programming Descriptors 147

Device programming 154

Relay programming 156

2.4. Programming system communications 164

Applications

Appendix 1. Programming data fields 171

Appendix 2. Summary of system commands 192

Part three.

Operation of the Vista-501V security and fire system

With centralized security consoles

3.1. general description possibilities for working with remote controls
centralized security 197

3.2. Sending messages to the monitoring station ADEMCO-685 199

Connecting the control panel to a telephone line 199

Programming the 200 control panel's auto-dial feature

3.3. System control from a personal computer (PC) 207

Connecting control panels

TO personal computer 207

Part four.

Compass Downloader

Main advantages 215

Structure of the Downloader 216 program

Installation on the network 217

Installation from floppy disk 218

Registration procedure 218

Communication setup 218

System Definition Statement 219

Autonomous communication 223

Partfifth.

OPERATION OF THE "VISTA-501V" SECURITY AND FIRE SYSTEM

WITH VIDEO SIGNAL SWITCH "VISTA VIEW–100"

General information about the integration of the Vista-501B system
with CCTV systems. 226

Video signal switcher “Vista View–100” Purpose.. 226

Switch operation on a four-wire interface 228

Installation and installation of the switch 229

Switch Programming 231

Preface

Alarm systems of the Vista-50 series from Ademco were among the first to appear on the domestic foreign market. technical means security alarm. High operational reliability and wide functionality, subject to their rational and competent use, are combined in systems with good design and are able to satisfy the needs of most owners. For more than 7 years, Vista-501V has been produced by MZEP-OKHRANA CJSC. IN this manual Based on practical operating experience, information about the purpose and capabilities of the Vista-501V system and its technical means is systematized, and methods for programming individual devices and the system as a whole are proposed.

The guide consists of two parts. The first part discusses issues of installation, configuration and installation programming of system hardware. The range of technical equipment discussed in the manual is determined on the basis of the “List...” of devices approved for use at facilities protected by units private security Ministry of Internal Affairs of the Russian Federation. The second part of the manual discusses programming of the Vista-501B alarm system.

The technique of programming using a wired
control panel, methodology for programming basic system
functions and operating modes.

The material is presented in a logically consistent form suitable
for study and may be useful as a reference guide
various categories of employees of organizations involved in equipping facilities with security equipment. As a result of development
in the production and certification of new Ademco instruments, some of the technical features described in this manual may, over time,
undergo changes.


Part one

Technical means

Security and fire system

"Vista-501B"

1.1. Are commonintelligence
O
system"Vista-501B"

The Vista-501B system (hereinafter referred to as the system) can be effectively used
use at such facilities as a bank branch, a small structure
regulated production or trading enterprise, a building with
whelped there by several independent organizations or at home
several owners. This is determined by the following functional options:
system capabilities:


  • Three types of alarm systems are provided: security, alarm and
    fire department;

  • Simultaneous monitoring of the status of up to 86
    protected areas;

  • Protected areas can be grouped to form non-
    dependent sections (from 1 to 8), which ensures separate use of the system by several owners;

  • Up to 75 users with their sex
    reticent access codes;

  • Users are divided into 7 hierarchical levels with different
    powers;

  • Supports both wired and radio methods
    receiving notifications from protected areas;

  • The system control is organized using wired or
    diochannel control panels with push-button keyboards;

  • Provides documentation of 224 events that occurred and
    service messages with information displayed on the control panel display, computer monitor or printed on a printer;

  • Programmable relay outputs of the system can be used to interface with domestic centralized monitoring consoles, turn on sound and light alarms, as well as devices household use;

  • The system has high level information content due to the possibility
    the ability to transmit alarm and service information in encoded form via a dial-up telephone communication channel to a centralized monitoring post and via a modem to an IBM-compatible personal computer;

  • 20 programmable timers provide flexible organization
    organizing the operation of the system according to a planned time schedule;

  • The system has a command test and self-test mode
    change of a number of parameters;

  • The programmed system configuration is saved when
    long-term loss or disconnection of supply voltage;

  • The programmed system configuration can be recorded
    sana to computer media and boot if necessary;

  • The technical means of the system have a high level of design,
    which makes it possible to satisfy the increased requirements of owners for the interior of premises.
System structure

The block diagram of the Vista-501V security and fire system is shown in Fig. 1.1.

IN structural diagram you can select the main block - control
panel, which is functionally an analogue of a reception and control panel
device. All hardware is connected to the control panel
systems:


  • Radial (wired) alarm loops;

  • Two-wire communication line for connecting addressable signals
    boards and devices;

  • Four-wire communication line for connecting control panels
    leniya, radio channel devices and relay modules;

  • Serial interface module for printing messages
    or communication with a computer;

  • External sounder.

System Programming Overview

The main element of the control panel is the microprocessor.
The microprocessor operates under the control of programs, finding...
stored in the system memory. The system memory consists of two parts: permanent
memory device (ROM) and reprogrammable storage
memory device (PROM). Information in ROM is recorded at the factory.
de-manufacturer and during system operation can only read from the ROM
vat. In PROM, information can be written and erased many times.

During the production process of the panel at the manufacturing plant, ROM is written
san subroutines for managing all elements of the system, such as
control panels, expanders, relay modules, etc. In ROM and PROM
a number of system characteristics are also recorded, which are called “factory
our installations." The system delivered to you from the factory is configured accordingly
with factory settings, which allows it to be used in some
in some cases, for example during initial inclusion and study. However, the factory settings may not be sufficient for operation.

Rice. 1.1. Block diagram of the Vista-501V system

Systems in the conditions of a specific object, which will require their changes.
Setting system parameters for a specific object is called its programming.

Programming can be done different ways:


  1. Using an alphanumeric control panel and program-
    61391. This is the most affordable and does not require additional
    no equipment method. The disadvantage is the duration and small
    visibility of the programming process.

  2. Using a PC located on site and connected to
    panels via the 4100SM module. This method is clear, one
    however, requires the use of special software
    COMPASS.
3. Using a remote PC located outside the facility and connected
connected to the panel via a telephone line. This method requires the use of
connection of COMPASS software and telephone modem.

Installation and registration of system hardware

The composition of the system devices used depends on the specific re-
tasks being solved. Installation of technical equipment includes installation and
connecting devices. To ensure the operation of any device in
the system requires its registration, which consists of assigning it
individual system address and entering into the system memory para-
meters of this device.

The rest of the manual contains material on the installation procedure and
stratification of the technical means of the system that have found the most widespread practice
technical application at protected sites. Accepted by Ademco
designations of technical means contain a four-digit number,
example, PU 6139. Domestic analogues produced by MZEP- JSC
SECURITY", in the designations they differ by adding the unit at the end of the number -
Nits, for example, PU 61391.

1.2. Control panel

Generalinformation

The control panel refers to the central reception and control panel.
roller system device. The delivery set includes: mounting box
starter with installed printed circuit board and mains power supply; pass-
port; key to the cabinet door lock; two connecting wires (black
red and red) with terminals for connecting the battery to the printed circuit
board; 8 resistors with a resistance of 2 kOhm for connecting to the wire
signaling loops as terminal elements; factory
installation and programming instructions.

The control panel mounting housing is used to accommodate the
chat board, mains power supply, backup battery, some
pov system devices, as well as input and output of cables for connecting
understanding of peripheral technical means of the system.

Housing installation

The housing is usually installed on the wall of the room. To ensure
ensuring the security of the system and restricting access to it, this is
tion must be protected. In production installation work next
should take into account the recommendations:


  • Install the housing using dowels or screws in a clean, dry
    Home place. Back wall the housing has 4 holes for this (see Fig. 1.2.).

  • All wiring must exit from the plug holes or rear wall.
    ki housing, preferably using metal piping.

  • It is advisable to plug all unused holes using
    I search for disc plugs and bolts.
Connecting the main unit

Inside the control panel mounting housing there is a circuit board
with a power switch and a block for connecting the power cable
power supply, transformer and printed circuit board with electrical and radio elements.

On printed circuit board control panel are located:

1. Contacts “RED+” and “BLK-” for connecting a backup battery.

2. Terminal block(30 pcs. in one row) for connecting low-
voltage output of the network transformer, radial loops signal-
lization, two-wire and four-wire address communication lines, sound
alarm, telephone line and grounding.

Really low!!! Call our office and check.

Vista-501 is one of the most powerful developments on the OPS market over the past few years. An alarm system based on Vista-501 (Vista-501) is intended for the protection of banks, offices, museums, shops, cottages, apartments, and small businesses. Wide functionality and modern design allow the device to be used indoors and on objects with increased requirements to the interior. Based on the Vista-501 (Vista-1) control panel, you can configure security, fire and alarm systems for any specific tasks.

) uses modern microprocessor technology and long-term memory (power outage does not lead to loss of information).
is a programmable device. It is pre-programmed with a set of standard values, but these can be changed to suit the requirements of any particular installation. Programming can be performed either directly at the installation site, or in the office when creating the appropriate device configuration and subsequent installation at the site.
Programming of the Vista-501 control panel can be done from an alphanumeric control panel or from a computer using boot software. Programming from a computer can be carried out directly from the workplace or remotely via a telephone line using a modem.
Besides traditional method programming in the control panel Vista-501 (Vista-501) uses the menu method.
The Vista-501 control panel is capable of supporting partitioned protected space, in which the physical components and functions of the system can be distributed among unrelated users.
The Vista-501 control panel provides multiple priority levels per partition, i.e., many users can be assigned different (including the same) priority levels.
The Vista-501 control panel provides planning capabilities: allows you to automate some aspects of its work; allows you to report opening and closing by exception; activate the output actions of the relay according to the schedule. Scheduled events are based on time windows.
In the control panel Vista-501 (Vista-501) the following can be used: regular schedules; holiday schedules; user-defined time schedules.
The Vista-501 control panel provides up to 20 timers available to the user to influence output devices at preset times and days.
Interface of the Vista-501 control panel with domestic centralized surveillance systems is ensured using relay modules.
The Vista-501 control panel is compatible with all Ademco equipment.

Main features:

  • connection up to 86 zones
  • ability to create up to 8 partitions
  • ability to control zones via radio channel
  • relay output programming
  • the ability to hand over an object through the Vista-501 security panel to a private security console

Specifications:

  • Number of alarm zones, pcs. up to 86
  • Number of sections up to 8
  • Number of built-in wire loops, pcs9
  • Number of wireless zones, pcs. up to 86
  • Number of addressable zones, pcs. up to 77
  • Number of user codes, pcs. up to 75
  • Number of relay outputs, pcs. up to 16
  • Operating supply voltage (variable), V220
  • Internally installed accumulator battery 12 V; 7 Ah
  1. Installation of zones should be carried out using KSPV 4*0.5 wire
  2. to power the security sensors connected to the expander, lay the main line from the Vista-501 panel using SHVVP wire 2*0.75
  3. control panels are very sensitive to cable length, so if the distance from the Vista-501 panel to the control panel does not exceed 30 meters, you can install KSPV 4*0.5; if it is longer, then it is better to play it safe and install KSPV 10*0.4
  4. It is better to hang the relay module next to the Vista-501 control panel
  5. when using an additional power source (RIP, BIRP) to power control units, expanders, relay modules, the minus of the RIP must be connected to the minus of the Vista-501 panel (terminal 7)
  6. when using the Vista-501 security panel for installation fire alarm With smoke detectors it is necessary to use four-wire sensors, type DIP44, and the sensors must be powered through an additional power source (RIP, BIRP) and a relay module
  7. it is advisable to conduct a two-wire address line (terminals 24, 25 of the Vista-501 panel) and a data input-output line (terminals 8, 9 of the Vista-501 panel) using twisted pair
  8. It is advisable to load the built-in power supply of the Vista-501 control panel (terminals 6, 7) at no more than half the power (no more than 370 Ma)

Note. The description and connection diagram of the Vista-501 security panel does not show all the capabilities of this system. This is what is now commonly called a “quick start”.