Ventilation system based on Daikin VAM. Daikin VAM350FB (supply and exhaust with recovery) Daikin product quality

Ventilation system based on Daikin VAM.  Daikin VAM350FB (supply and exhaust with recovery) Daikin product quality
Ventilation system based on Daikin VAM. Daikin VAM350FB (supply and exhaust with recovery) Daikin product quality

RUB 36,900

Wall-mounted air conditioner Daikin ATYN25L/ARYN25L

With automatic mode. With heating mode. Heating power 2800 W. With self-diagnosis function. Noise level 25 dB. Type of indoor unit: wall-mounted. . Cooling power 2500 W. With auto restart. With remote control. Refrigerant - R410A. Maximum length communications 20 m. With on/off timer. Serviced area 25 m2. Type of air conditioner - split system.

buy V online store Ziwo.ru

loan possible

photo

RUB 48,800

Air conditioner Daikin ATYN25L/ARYN25L Nord-40

With a service area of ​​25 m2. Auto restart. Auto mode. Mode supply ventilation . With a noise level of 25 dB. On/off timer. With heating power of 2800 W. Type of air conditioner - split system. Type of indoor unit: wall-mounted. With cooling power of 2500 W. With a maximum communication length of 20 m. Self-diagnosis. Heating mode. Remote control. Refrigerant - R410A.

buy V online store MirCli.ru

loan possible | Pickup possible

photo

RUB 48,800

Daikin ATYN25L/ARYN25L Nord-40 air conditioner 2.6 kW

Type of indoor unit: wall-mounted. With heating mode. With self-diagnosis function. Noise level 25 dB. With forced ventilation mode. Cooling power 2500 W. With remote control. The maximum length of communications is 20 m. Heating power is 2800 W. Type of air conditioner - split system. Serviced area 25 m2. With auto restart. With on/off timer. Refrigerant - R410A. With automatic mode.

buy V online store Proclimatgroup.ru

loan possible

photo

RUB 35,040

Wall-mounted air conditioner Daikin ATYN25L/ARYN25L Nord-30

Supply ventilation mode. Type of indoor unit: wall-mounted. Heating mode. Self-diagnosis. Auto restart. With heating power of 2800 W. Type of air conditioner - split system. Refrigerant - R410A. With a maximum communication length of 20 m. Remote control. With a service area of ​​25 m2. With a noise level of 25 dB. On/off timer. Auto mode. With cooling power of 2500 W.

V online store Ziwo.ru

loan possible

photo

RUB 37,900

Air conditioner Daikin ATYN25L/ARYN25L

With heating mode. Heating power 2800 W. Noise level 25 dB. With forced ventilation mode. With auto restart. Cooling power 2500 W. Type of air conditioner - split system. The maximum length of communications is 20 m. Refrigerant - R410A. With automatic mode. Type of indoor unit: wall-mounted. With remote control. With on/off timer. Serviced area 25 m2. With self-diagnosis function.

V online store MirCli.ru

loan possible | Pickup possible

photo

RUB 47,800

Daikin ATYN25L/ARYN25L Nord-30 air conditioner 2.6 kW

Type of indoor unit: wall-mounted. Type of air conditioner - split system. With a maximum length of communications of 20 m. Heating mode. On/off timer. Supply ventilation mode. Self-diagnosis. With cooling power of 2500 W. Auto mode. Refrigerant - R410A. With heating power of 2800 W. Auto restart. With a service area of ​​25 m2. With a noise level of 25 dB. Remote control.

V online store Proclimatgroup.ru

loan possible

photo

RUB 35,400

Wall-mounted air conditioner Daikin ATYN25L/ARYN25L Nord-40

With self-diagnosis function. With auto restart. With on/off timer. Refrigerant - R410A. With remote control. Heating power 2800 W. With automatic mode. With forced ventilation mode. Cooling power 2500 W. Type of air conditioner - split system. Type of indoor unit: wall-mounted. The maximum length of communications is 20 m. With heating mode. Serviced area 25 m2. Noise level 25 dB.

V online store Ziwo.ru

loan possible

photo

RUB 47,800

Air conditioner Daikin ATYN25L/ARYN25L Nord-30

Remote control. With cooling power of 2500 W. With a maximum length of communications of 20 m. Autorestart. Type of air conditioner - split system. With a noise level of 25 dB. Supply ventilation mode. With a service area of ​​25 m2. Auto mode. Refrigerant - R410A. Heating mode. Type of indoor unit: wall-mounted. With heating power of 2800 W. Self-diagnosis. On/off timer.

V online store MirCli.ru

loan possible | Pickup possible

photo

RUB 49,800

Daikin ATYN35L/ARYN35L Nord-30 air conditioner 3.5 kW

The maximum length of communications is 20 m. With self-diagnosis function. Noise level 27 dB. Refrigerant - R410A. With auto restart. Type of indoor unit: wall-mounted. With forced ventilation mode. With automatic mode. Serviced area 33 m2. With on/off timer. Cooling power 3300 W. With heating mode. Heating power 3400 W. With remote control. Type of air conditioner - split system.

V online store Proclimatgroup.ru

loan possible

photo

RUB 37,160

Wall split system Daikin ATYN35L/ARYN35L Nord-30

Type of indoor unit: wall-mounted. With a service area of ​​33 m2. Self-diagnosis. Refrigerant - R410A. Heating mode. Auto mode. Supply ventilation mode. With cooling power of 3300 W. Remote control. Auto restart. With heating power 3400 W. Type of air conditioner - split system. With a noise level of 27 dB. With a maximum communication length of 20 m. On/off timer.

V online store Ziwo.ru

loan possible

photo

RUB 39,900

Air conditioner Daikin ATYN35L/ARYN35L

Type of indoor unit: wall-mounted. The maximum length of communications is 20 m. With heating mode. Serviced area 33 m2. With self-diagnosis function. With forced ventilation mode. With auto restart. Noise level 27 dB. With automatic mode. With on/off timer. Heating power 3400 W. With remote control. Type of air conditioner - split system. Refrigerant - R410A. Cooling power 3300 W.

V online store MirCli.ru

loan possible | Pickup possible

photo

67,800 rub.

Daikin ATYN50L/ARYN50L Nord-40 air conditioner 5 kW

With a service area of ​​53 m2. Type of indoor unit: wall-mounted. Heating mode. Auto restart. With a heating power of 5500 W. With cooling power of 5300 W. Supply ventilation mode. Remote control. Self-diagnosis. Auto mode. Type of air conditioner - split system. Refrigerant - R410A. With a noise level of 34 dB. With a maximum communication length of 20 m. On/off timer.

V online store Proclimatgroup.ru

loan possible

photo

RUB 39,300

Wall split system Daikin ATYN35L/ARYN35L

Country: Japan; Manufacturer: Japan; Warranty: 3 years; INDOOR UNIT: ATYN35L; Cold, kW: 3.3; Heat, kW: 3.47; Cooling consumption, kW: 1.08; Heating consumption, kW: 1.08; Energy efficiency EER Cooling: 3.06; Energy efficiency COP Heating: 3.54; Air consumption Cooling, mh: 633; Air consumption Heating, mh: 633; Noise level internal bl. Cooling, dBa: 27; Noise level internal bl. Heating, dBa: 27; Max route length, height difference, m: 20; d freon pipes: 6.35 9.5; Dimensions

V online store Ziwo.ru

loan possible

photo

RUB 49,800

Air conditioner Daikin ATYN35L/ARYN35L Nord-30

Type of indoor unit: wall-mounted. Heating mode. Auto restart. With heating power 3400 W. With cooling power of 3300 W. Remote control. With a service area of ​​33 m2. Supply ventilation mode. Self-diagnosis. Auto mode. Type of air conditioner - split system. With a noise level of 27 dB. Refrigerant - R410A. With a maximum communication length of 20 m. On/off timer.

V online store MirCli.ru

loan possible | Pickup possible

photo

66,800 rub.

Daikin ATYN50L/ARYN50L Nord-30 air conditioner 5 kW

Type of indoor unit: wall-mounted. The maximum length of communications is 20 m. With heating mode. Cooling power 5300 W. With self-diagnosis function. With auto restart. With forced ventilation mode. With automatic mode. With on/off timer. Serviced area 53 m2. Noise level 34 dB. With remote control. Heating power 5500 W. Type of air conditioner - split system. Refrigerant - R410A.

V online store Proclimatgroup.ru

loan possible

photo

RUB 37,510

Wall split system Daikin ATYN35L/ARYN35L Nord-40

Country: Japan; Manufacturer: Malaysia; Warranty: 3 years; Cold, kW: 3.30; Heat, kW: 3.47; Cooling consumption, kW: 1,080; Consumption at heating, kW: 0.980; Energy efficiency EER Cooling: 3.06; Energy efficiency COP Heating: 3.54; Annual energy consumption, kWh: 540; Air consumption Cooling, mh: 633; Air consumption Heating, mh: 633; Noise level internal bl. Cooling, dBa: 27; Noise level internal bl. Heating, dBa: 27; Max route length, height difference, m: 2010; d freon pipes,

V online store Ziwo.ru

loan possible

  • Highly efficient, energy-saving ventilation units using heat and moisture recovery from the room.
  • The presence of a bypass valve, thanks to which it is possible to naturally cool the air in summer period.
  • Wide range of units from 150 to 2000 m3/h.
  • Reduced energy consumption due to fans running on direct current.
  • Possibility of connecting an air quality sensor, CO2.
  • Highly efficient heat exchanger with increased permeability and efficiency of about 90%.
  • No condensate drainage, and therefore no drainage system.
  • Ability to control the anti-freeze system.
  • Possibility of adjusting the excess of supply air volume over exhaust air, up to 20%.

Additional options and accessories

DAIKIN VAM series heat exchangers are not equipped with frost protection. When operating ventilation units below -10 0 C, it is desirable to install frost protection, which includes:

1. Air heater.
2. Thermostat.
3. Relay.
4. Differential pressure sensor

Installation of an additional air heater is necessary when the structure operates at temperatures below -10 degrees. Its power is initially calculated for maximum air flow. If, as the outside temperature decreases, the air flow decreases, the formula is used to calculate the heater power:

N= -0.33x(T+15)xL


Where: N- heater power, calculated in kW,
T-minimum design temperature for a specific region,
L- air flow in m3/hour.

The heater must be controlled by a capillary thermostat (Shuft NET-5/HY) with an operating temperature range from -30 0 C to +30 0 C, through a solid-state relay or magnetic starter.

ThermostatSolid state relay
Differential pressure sensor PS500B
Duct heater
Price: 4200 rub. Price: from 1250 rub. Price: 2100 rub. Price: from 2500 rub.

A magnetic starter, unlike a relay, although it has a lower cost, also has a number of disadvantages, one of which is contact noise when turning the load on and off. To avoid extraneous noise during operation of the installation heater, it is advisable to install a solid-state relay that is completely silent in operation. Just like heaters, relays are selected depending on power.
If the recuperator is planned to be installed in a warm room, then it is advisable to additionally install air dampers at the air inlet and outlet from the unit to the street, which will open when the unit is turned on and closed when it is turned off.
In order to be able to connect electrically driven air dampers to the installation, it is necessary to use a differential pressure sensor, the sensors of which are installed before and after supply fan. A pressure sensor is also required when a frost protection kit is connected to the installation. As a result of the fan triggering when the unit is turned on, a pressure difference is created and the sensor sends a signal to open the air dampers and to the frost protection device.
PS500B Operating Instructions

Control panel for air handling unit DAIKIN

Air handling unit control panel BRC301B61 allows you to remotely control it, switch operating modes with or without a recuperator (relevant in the summer, when the air temperature drops at night and you can cool the room at
using street air), makes it possible to turn on the unit in FRESH UP mode, when the air inflow exceeds its exhaust by 20%, which is very important for normal operation exhaust ventilation in the kitchen, bathroom and bathroom. Using the control panel, you can set a timer and regulate the volume of air supplied to the room. The display shows information about the operating mode of the unit, set timers, replacing dust filters and the need to clean the heat exchange cassette.
Factory fan speed settings can be changed using service settings. By using service menu, you can select the maximum and minimum fan speeds from 14 possible.

Price: 13,900 rub.

Technical characteristics of recuperators DAIKIN VAM 150-2000

Parameter/Model VAM-150FA VAM-250FA VAM-350FB VAM-500FB
Price Rub 62 600
72 900
83 200
91 900
Air flow (max) m3/h 150 250
350 500
Power consumption W 110 110
210
210
% 85 90 90 90
Noise level (min-max) dB(A) 20 - 27
21- 29 23 - 32 24 - 33
Supply voltage IN 220-240 V, 1 phase, 50 Hz
-10 … +40°C, relative humidity no more than 80%

Parameter/Model VAM-650 FB VAM-800 FB
VAM-1000 FB
Price Rub 102 600
113 800
127 400
Air flow (max) m3/h 650 800
1000
Power consumption W 260 480
480
Recovery efficiency (max) % 90 90 90
Noise level (min-max) dB(A) 27 - 34
31- 36 31 - 36
Supply voltage IN 220-240 V, 1 phase, 50 Hz
Guaranteed outside temperature range

Parameter/Model VAM-1500 FB
VAM-2000 FB
Price Rub 141 500
251 200
Air flow (max) m3/h 1500 2000
Power consumption W 900 900
Recovery efficiency (max.) % 90 90
Noise level (min-max) dB(A) 34 - 39 35 - 40
Supply voltage IN 220-240 V, 1 phase, 50 Hz
Guaranteed outside temperature range –10 … +40°C, relative humidity no more than 80%

*-installations with the FB index include a bypass.

Installation dimensions


The HRV system helps create a comfortable environment by interacting with the air conditioning system. Daikin's HRV (heat recovery ventilation) system returns thermal energy lost during ventilation and smooths out the change in room temperature caused by ventilation, thereby maintaining a comfortable, clean environment. It also reduces the load on the air conditioning system and saves energy.

In addition, the HRV system works in conjunction with the VRV® system, Sky Air and other systems Daikin air conditioning, automatically switches to ventilation mode, which increases energy saving. The HRV system is controlled centrally from the remote control remote control air conditioner This provides easy general management air conditioning and ventilation.

Current configurations include models with a DX heat exchanger and/or humidifier - the DX heat exchanger helps protect personnel from direct action cold air flow during the heating cycle, and vice versa. High static pressure increases system design flexibility.

1. ENERGY EFFICIENCY

Reduce block size by more than 30%

Using high quality paper (HEP) element and optimal design fan and ducts air flow made it possible to obtain a very compact unit, while maintaining the 28% reduction in the load on the air conditioning system achieved by previous models. The height of the main unit is reduced by 40mm, allowing it to be easily installed in areas where space is limited, such as suspended ceilings.

Reducing the load on the air conditioning system by an average of 28% (maximum 40%) includes:
- 20% due to operation in full heat exchange mode (compared to conventional fans)
- 6% due to automatic switching of ventilation mode
- another 2% by regulating pre-cooling and heating (reduces the load on the air conditioning system without the HRV system running, when the air remains clean for a certain time after switching on air conditioner.)

Note: Above values ​​may vary depending on weather and other conditions environment at the location where the unit is installed

Brand element made from high quality paper (HEP)

The heat exchanger element is made of high quality paper (HEP), which has excellent moisture-absorbing and humidifying properties. This allows the heat exchanger to quickly recover the heat contained in the latent heat (steam). The element is made of fire-resistant material treated with an agent to prevent deformation.

Heat exchanger element operation


Automatic switching to effective schemes work

During the work process automatic switching on optimal scheme according to current prevailing conditions



2. DESIGN FLEXIBILITY

Operation at outside temperatures down to -15°C

If the outside suction air temperature drops below -10°C, the unit goes into intermittent operation, which prevents the heat exchanger element from freezing and condensation forming in the unit.

Intermittent Operation = A thermistor (standard equipment) in the unit senses the outside air temperature. The operation of the unit changes according to a certain temperature.

Compact dimensions

The compact dimensions of the HRV unit allow it to be easily installed in narrow space between the suspended ceiling and the ceiling, as well as in irregularly shaped spaces.

Compact design

The unit can be mounted horizontally or upside down, depending on the characteristics of the installation site. The 450 mm square inspection hatch makes it easy to carry out maintenance and replacement heat exchanger element.

Quiet operation

Levels sound pressure are very low and equal to 20.5 dBA (VAM150FA)

3. CLEAN AIR

Fresh air supply

The user can select 2 fresh air modes using the remote control.

Preventing dust from settling

Prevents dust from settling thanks to direct installation of air ducts.

Cleaning the filter

The remote control signal indicates when air filter requires cleaning.




VKM SYSTEM CHARACTERISTICS


1. ENERGY EFFICIENCY

Natural cooling at night allows you to save energy at night when the air conditioning system is turned off. Thanks to the ventilation of rooms in which office equipment is located, which increases the temperature in the premises, night mode operation allows you to reduce the cooling load when the air conditioning system is turned on in the morning.

Nighttime free cooling only works when connected to multi-unit or VRV® systems.

Night free cooling is factory set to “off” but can be enabled by your Daikin dealer at your request.

Effective preparation outside air via heat exchanger and cooling/heating switching mode

Indoor unit with outdoor air preparation.

With the help of outside air, the temperature can be brought to a temperature close to the indoor air temperature, with minimal cooling power.


2. DESIGN FLEXIBILITY

High static pressure

Modifications to the fan design, including the use of multi-arc blades, a thinner volute and optimal angle Fan spirals provide increased operating efficiency. Significantly higher static pressure is achieved due to improved fan characteristics. This reduces unit placement restrictions and allows for flexible duct design.


Connectivity of indoor units

Connectable indoor units can account for up to 130% of the power of the outdoor unit

Prices for Daikin ventilation units

HRV Heat recovery ventilation units

VAM150F VAM250F VAM350F VAM500F VAM650F VAM800F VAM1000F VAM1500F VAM2000F
1621 € 1919 € 2190 € 2423 € 2702 € 2981 € 3354 € 3726 € 6615 €

HRV plus Ventilation units with heat recovery, cooling and humidification

HRV plus WITH DIRECT COOLING AND HUMIDIFICATION
VKM50GM VKM80GM VKM100GM
9502 € 10433 € 10900 €

HRV plus WITH DIRECT COOLING
VKM50G VKM80G VKM100G
9129 € 9874 € 10153 €

The HRV system helps create a comfortable environment by interacting with the air conditioning system. The HRV (Heat Recovery Ventilation) system recovers thermal energy lost during ventilation and smoothes the change in room temperature caused by ventilation, thereby maintaining a comfortable, clean environment. It also reduces the load on the air conditioning system and saves energy.

In addition, the HRV system works in conjunction with VRV®, Sky Air and other systems, automatically switching to ventilation mode, which increases energy savings. The HRV system is controlled centrally from the air conditioner remote control. This provides simple overall control of air conditioning and ventilation.

These configurations include models with a DX heat exchanger and/or - the DX heat exchanger helps protect personnel from direct exposure to cold airflow during the heating cycle, and vice versa. High static pressure increases system design flexibility.

1. ENERGY EFFICIENCY

Reduce block size by more than 30%

The use of high quality paper (HEP) element and the optimal design of the fan and airflow channels result in a very compact unit, while maintaining the 28% reduction in air conditioning load achieved by previous models. The height of the main unit is reduced by 40mm, allowing it to be easily installed in areas where space is limited, such as suspended ceilings.

Reducing the load on the air conditioning system by an average of 28% (maximum 40%) includes:
- 20% due to operation in full heat exchange mode (compared to conventional fans)
- 6% due to automatic switching of ventilation mode
- another 2% by regulating pre-cooling and heating (reduces the load on the air conditioning system without the HRV system running, when the air remains clean for a certain time after switching on.)

Note: The above values ​​may vary depending on the weather and other environmental conditions where the unit is installed

Brand element made from high quality paper (HEP)

The heat exchanger element is made of high quality paper (HEP), which has excellent moisture-absorbing and humidifying properties. This allows the heat exchanger to quickly recover the heat contained in the latent heat (steam). The element is made of fire-resistant material treated with an agent to prevent deformation.

Heat exchanger element operation

Automatic switching to efficient work patterns

During operation, automatic switching to the optimal scheme occurs in accordance with the current prevailing conditions



2. DESIGN FLEXIBILITY

Operation at outside temperatures down to -15°C

If the outside suction air temperature drops below -10°C, the unit goes into intermittent operation, which prevents the heat exchanger element from freezing and condensation forming in the unit.

Intermittent Operation = A thermistor (standard equipment) in the unit senses the outside air temperature. The operation of the unit changes according to a certain temperature.

Compact dimensions

The compact dimensions of the HRV unit allow it to be easily installed in narrow spaces between the suspended ceiling and the ceiling, as well as in irregularly shaped spaces.


Compact design

The unit can be mounted horizontally or upside down, depending on the characteristics of the installation site. The square inspection hatch measuring 450 mm allows for easy installation of the heat exchanger element.


Quiet operation

Sound pressure levels are very low at 20.5dBA (VAM150FA)


3. CLEAN AIR

Fresh air supply

The user can select 2 fresh air modes using the remote control.


Preventing dust from settling

Prevents dust from settling thanks to direct .

Cleaning the filter

The remote control signal indicates when the air filter requires cleaning.

VKM SYSTEM CHARACTERISTICS

1. ENERGY EFFICIENCY

Natural cooling at night allows you to save energy at night when the air conditioning system is turned off. By ventilating rooms containing office equipment, which raises the room temperature, night mode reduces the cooling load when the air conditioning system is turned on in the morning.

Nighttime free cooling only works when connected to multi-unit or VRV® systems.

Night free cooling is factory set to “off” but can be enabled by your Daikin dealer at your request.

Efficient preparation of outside air via heat exchanger and cooling/heating switching mode

Indoor unit with outdoor air preparation.

With the help of outside air, the temperature can be brought to a temperature close to the indoor air temperature, with minimal cooling power.

2. DESIGN FLEXIBILITY

High static pressure

Modifications to the fan design, including the use of multi-arc blades, a thinner volute and an optimized fan volute angle, provide improved operating efficiency. Significantly higher static pressure is achieved due to improved fan characteristics. This reduces unit placement restrictions and allows for flexible duct design.

Connectivity of indoor units

Connectable indoor units can account for up to 130% of the power of the outdoor unit

HRV Heat recovery ventilation units

VAM150FVAM250FVAM350FVAM500FVAM650FVAM800FVAM1000FVAM1500FVAM2000F
1621 € 1919 € 2190 € 2423 € 2702 € 2981 € 3354 € 3726 € 6615 €

HRV plus Ventilation units with heat recovery, cooling and humidification

HRV plus WITH DIRECT COOLING AND HUMIDIFICATION
VKM50GMVKM80GMVKM100GM
9502 € 10433 € 10900 €

HRV plus WITH DIRECT COOLING
VKM50GVKM80GVKM100G
9129 € 9874 € 10153 €

Daikin Europe NV- a subsidiary of Daikin Industries Ltd. It is the head office for Europe, Russia, Africa and the Middle East. Funded and has technical support from the Japanese parent company.

Daikin ( Daikin ) was founded in 1973 (Belgium) due to the growing demand in Europe for high-quality, reliable air conditioning systems. Initially, it was a small assembly plant, which in a short time transformed into the most modern air conditioning plant in European countries (its area is more than 150,000 sq.m.) It produces products perfectly adapted to the specific needs of Russian market. Daikin equipment is supplied to many countries around the world.

PRODUCTS

Daikin Europe NV designs and manufactures high-tech air conditioning equipment for domestic and industrial purposes, as well as air purifiers and ventilation systems , which take exhaust air from the room and supply Fresh air from the street.

Daikin heat recovery ventilation modifies the temperature and humidity of the supply air to suit the room's microclimate. Due to this, a balance is achieved between indoor and outdoor conditions and the load on the air conditioning system is significantly reduced.
Heat recovery ventilation units (HRV systems) can operate independently or together with the entire air conditioning system. The equipment is used in residential, office and commercial premises, sports facilities, as well as restaurants, cafes and other similar facilities.

Advantages of the HRV system

  • installation possible in suspended ceiling or on the floor
  • The most compact equipment in its class
  • efficient heat exchange element
  • new model has more high efficiency heat exchanger (efficiency of latent heat and water vapor removal)
  • moisture removal
  • twice the rate of moisture absorption
  • central and centralized management
  • reduction of heat load on air conditioners by 28%

DAIKIN PRODUCT QUALITY

Daikin equipment is energy efficiency, energy savings, ease of placement, environmental friendliness, ease of control, optimal configuration and compatibility of climate control equipment.

The recognized quality of a company's products is determined special attention, which is focused on the quality of work performed at all stages of production and after-sales service of Daikin equipment. Product quality is confirmed by ISO9001 (guarantees product quality) and EUROVENT certificates (members of this organization voluntarily provide their products for testing and evaluation in independent laboratories of the European Institute for Quality Control EUROVENT - the only independent certification body refrigeration equipment and air conditioners).

Ventilation units with heat recovery

Characteristics:

  • The compact and energy-saving HRV ventilation system has a wide range of models (9 models with air flow from 150 to 2000 m3/h). This is very good decision for ventilation of apartments and offices.
  • The permissible outside air temperature range is from -15 °C to +50 °C. The scope of application has been expanded with the possibility of energy savings.
  • Low noise level. The new Multi Arc Blade Fan provides a noise level of 27 dBA (for VAM150FA), which allows the ventilation unit to be installed even in sleeping areas.
  • More efficient and compact heat exchanger. The transfer rate of latent heat and water vapor has been increased, which has made it possible to reduce the dimensions of the heat exchanger by 25% compared to the previous model.
  • Fresh Up mode eliminates hits unpleasant odors from the toilet and cold air through leaks into the room.
  • It is possible to operate air conditioning and ventilation together, which increases the efficiency of the climate system and allows you to control:
  1. joint start-up or shutdown;
  2. the ability to control ventilation independently of the air conditioner;
  3. changing the ventilation mode (auto/heat exchange mode/no heat exchange);
  4. indication of filter contamination;
  5. changing the air flow speed (high/low);
  6. activating the function pre-treatment air before starting the air conditioner.

*- The sound pressure level is measured in heat exchange mode.

HRV plus

Ventilation units with heat recovery, cooling and humidification

Characteristics:

  • Humidifier and cooler integrated into a ventilation unit with heat recovery.
  • Increased free pressure due to improved fan characteristics.
  • Heat removal function: heat accumulated in the room during the day is removed at night.
  • Ventilation units are compatible with existing systems DAIKIN control.
  • VKM units can only be connected to VRV outdoor units: RXYSQ-P, RXY(H)QP,
  • REY(H)Q-P, RTSYQ-P and RWEYQ-P(R).
  • Control ventilation units designed for working together with indoor units of VRV system. Installation of VKM and indoor unit controlled from one remote control.

AHU

Central air conditioners (ventilation)

Thanks to the variety of configurations and types of execution, flexibility in the selection of equipment, Daikin central air conditioners can be used:

The standard range of Daikin central air conditioners (D‑AHU) includes units of 27 standard sizes with air capacity from 1100 to 124000 m3/hour. In addition, it is possible to manufacture according to individual sizes in increments of 50 mm, and this does not lead to an increase in cost.

In 2011, Daikin began producing units of the new model range, called Easy AHU. The productivity of new products is from 500 to 30,000 m3/hour. Easy AHU units are structurally simpler and, accordingly, cheaper than standard ones.

Energy efficiency

All installations are designed taking into account high energy efficiency requirements. When developing equipment, the thermophysical properties of heat exchange surfaces, the coefficient useful action electric motors, degree of filtration, insulation, reduction of friction and pressure drops in the air flow. The energy efficiency of installations can be further increased through heat recovery.

Efficient air treatment

Depending on the requirements for air purity, central air conditioners are equipped with filters of varying degrees of efficiency:

  • synthetic corrugated
  • flat in aluminum steel mesh
  • compact and soft pouches
  • absorption
  • deodorizing

All filters are mounted on commercially available frames with seals.

To avoid dust getting into air channel by doing Maintenance, the filters are removed from the dirty side.

The units can be completed different types and humidifier models. Options are available with completely removable humidifiers or a removable surface evaporation humidifier section.

The installations may include heat exchangers with intermediate coolant or freon, electric heaters, fans, heat recuperators, gas-burners, noise suppressors, controls, automation and safety.

D‑AHU units can work together with chillers and large compressor and condensing units, including Daikin inverter compressor and condensing units using ozone-friendly refrigerant R‑410A.

Variety of designs

The overall dimensions of the central air conditioner can be selected depending on the actual installation conditions. The design is based on supporting frame and profiles made of aluminum (or anodized aluminum, which is best suited for work in aggressive environments) with a cross-section of 40x40 or 60x60 mm. There are modifications of profiles with a cross section of 60x60 mm with a thermal insulating insert to reduce heat loss. Profiles with oval inner surface recommended for use in the food industry, medicine, and other areas with special requirements to hygiene.

The panels can be flat, 25 and 46 mm thick, or stepped, 42 and 62 mm thick.

Stepped panels allow you to get a flat surface inside the product. Insulation is made of polyurethane foam (40-50 kg/m3) or fibrous mineral wool(90 kg/m3).

In the central Daikin air conditioners components produced by companies that are world leaders in their fields are used: Daikin, Siemens, Belimo, Nicontra, Comefri, Gebhardt.


Modern management

The units are equipped with a control cabinet based on a digital controller with all power and control connections. The delivery package of units can optionally include sensors, servos and protective devices. Along with automation, it is possible to order elements of the hydraulic piping of water heat exchangers: two- and three-way control valves, pumps, shut-off control valves.

Fast design, installation, commissioning