Error codes for the Neva Lux gas boiler - malfunctions and what to do in a specific situation. Error codes for the gas boiler Neva Lux - malfunctions and what to do in a specific situation Boiler Neva Lux error 03 what to do

Error codes for the Neva Lux gas boiler - malfunctions and what to do in a specific situation. Error codes for the gas boiler Neva Lux - malfunctions and what to do in a specific situation Boiler Neva Lux error 03 what to do

What does error 01 mean, how to troubleshoot problems when repairing Neva Lux?

Dual-circuit gas boilers Neva Lux 8624, 8230, 8224 are a wall-mounted device with forced circulation coolant (water or antifreeze). Repair and maintenance of Neva Lux boilers is carried out according to official instructions by a specialized service organization, which also deals with installation, commissioning and maintenance work with the supply, replacement of faulty ones with new spare parts for this heating equipment Neva Lux.

So, with error 01, the flame does not ignite in the combustion chamber, or ignition begins, but is unsuccessful - the Neva boiler does not work. In summary, in this case there may be one or several reasons for error 01 at the same time. Let's consider all the reasons for the occurrence emergency situation and give a full range of recommendations for repairs gas boiler Neva Lux when error 01 occurs. Technical information is presented for service engineers of gas equipment repair organizations.

Error 01 in electronic board control is often found when repairing gas boilers in various manufacturers electrically dependent heating equipment with electronically controlled. The first common malfunction, lack of ignition, is the incorrect operation of the entire chain of energy-dependent and mechanical actions, starting from the pilot and ending with the main one. gas burner. Similar problems when error 01 occurs apply to wall-mounted boilers Visman Vitopend 100, Baksi, Kiturami, Electrolux, Ariston, Immergaz, Neva Lux 8224 and other models from various manufacturers. At external inspection gas appliance, you need to make sure that all the manufacturer’s recommendations for installing a gas boiler are followed: electricity, electronics, gas, chimney, air flow, correct installation of the Neva Lux boiler according to wiring diagram and gas regulations.

Repair of the Neva Lux gas boiler with error 01 information begins with checking the gas supply to the heating boiler fittings. Next, we check all RTs for working condition, observing the contact ability of the relay. Diagnostics of the gas modulator valve, checking static and dynamic pressure. By default, the ignition and ionization elements are subject to testing and maintenance. In this case, the gaps should be maintained relative to the burner section along the two electrodes. Eliminate distortions and mechanical damage, interfering correct settings boiler Diagnostics of the ignition transformer unit (coil), if there is no power to the ignition electrode.

During the repair of the Neva Lux boiler operating on liquefied gas, it is necessary to prepare documents for the last filling of the gas tank (technical data of the fuel), a technical agreement. gas boiler maintenance and call a specialist service department for gas diagnostics and repairs. apparatus.

Timely, constant maintenance of Neva Lux gas boilers ensures uninterrupted operation of equipment, warmth and comfort in your homes. Carrying out scheduled repairs, necessary replacement spare parts you extend the life of Neva Lux boilers and make the right investment.

The problem is that I bought this a long time ago washing machine indesit wise107s and bought my daughter another one that is not indesit, I don’t have a car, it’s gold, only the paint on the top panels at the bottom on the sides is not peeling off nicely. Now, if the manufacturers thought about the fact that many people complain about painting cars. They came up with a good paint job, then there’s no need to invent anything else .The model would be the best. Can’t be compared with the indesit from Ukrainian manufacturers. You could sell this one model. People know that it’s super, I don’t need another. I would have bought the same one, but unfortunately it was discontinued. Very bad, I don’t want another model, I don’t even want a better one, because I already know this one. But they bought my daughter’s from the bay floundering and it’s not the same coat. People want to buy, they want to spend their money, and manufacturers are rushing for different bells and whistles for cars. But we need all sorts of cool bells and whistles are not needed, in Kharkov the price of electricity is crazy. Soon people with such prices will stop buying electrical appliances of any kind. It’s enough that at one time we bought toasters, microwave bread makers, multicookers, toasters, coffee makers, now everything is lying around as unnecessary, because the price of electricity is sky-high , and the salaries are cheap, these cool goods are not for us. So if you want people to buy something, you need to do something about the prices of the goods, and most importantly with the price of electricity, otherwise soon all the big supermarkets will have to close because will not be profitable. I worked at the Barabashov market for many years. People used to buy up heaps of goods, but now half of the stores are closed. Privoznogo there is no product, but they sell such junk, there is nothing to buy for themselves. No good boots, no good clothes. There is nothing to look at, everyone is running away from the market to another business. The market is dead, there is nothing to do there. So are electronics supermarkets. Do the owners of large stores really not understand this, after all the owners are rich people. Before they can even blink an eye, they will become poor if people don’t buy anything from them. Then let these rich people try to sell their store or a bunch of goods that have turned into old trash that no one takes. After all, everything can be bought now without leaving home. Who needs to buy online and cheaper and don’t have to go three nine lands away to burn gasoline to buy household appliances in the supermarket. People are not fools to pay more for renting a store for the salaries of salespeople, managers and staff. PEOPLE DON’T HELP OUT THE SPECULANTS And MONOPOLIST THIEVES. If you don’t help them out, they will disappear on their own, they won’t steal from themselves. A good product should cost money, but excuse me, not as much as we all even sell medicine to us through fourth hands. For example, a factory She produced a good medicine abroad, selling it, she earned money from this medicine. Wholesalers bought it, brought it to us in the city, sold it to a warehouse, also earned money. Then they brought it to the pharmacy, sold it to us, and also earned money. And where can we earn so much, we don’t steal. Consider how many people have made money from one medicine. That’s why they fool us, they succeed, that’s why pharmacies are now like uncut dogs, at every turn. They also sell electrical and household goods. Finding something real good now is also a problem. Cigarettes are counterfeited too, if they grew tobacco, dried it, made cigarettes from it, they would have already gone down the drain and gone bankrupt. Either the tobacco would not have grown, or the harvest would not be good, etc. That means they need to make money from you. There is no tobacco there, but all the grass with additives and flavorings. That's all. The owners of the Bentley factory have a three-story mansion. And you have a cough, shortness of breath and lung cancer in order to help out the pharmacy business. Remember the movie a long time ago YOU ​​WAS ME-I'M FOR YOU. Don't help out the deceivers with vodka, same thing, cheap alcohol plus distilled water. And that’s it. Durilovka in everything. People will be vigilant, oh how I feel sorry for you all.

Error codes and malfunctions of Neva Lux boilers

Stopping the operation of the Neva Lux boiler, caused by a failure or malfunction of any of its systems, is accompanied by the corresponding error code being displayed on the control panel display, which makes it easier to detect the malfunction.

Error codes possible reasons and troubleshooting methods

Error 01- Problems associated with unsuccessful ignition. The boiler is not working.

Gas supply problems - Open stopcock on the gas pipeline, or check the pressure in the cylinder (liquefied gas.)

The spark plug is faulty - Replace the spark plug.

The electrical circuit of the spark plug is broken - Check electrical circuit and contacts.

Incorrect gap between spark plug and burner section - Set gap (5+0.5 mm).

A spark from the spark plug electrode jumps onto the combustion chamber shell - Bend back the combustion chamber shell at the place where the spark plug is installed.

The spark plug is dirty - Wipe the spark plug from dust and degrease.

The ionization spark plug is faulty - Replace the spark plug.

The electrical circuit of the ionization spark plug is broken - Check the electrical circuit and contacts.

Incorrect gap between the ionization plug and the burner section - Set the gap (3+0.5 mm).

The ignition transformer is faulty - Replace the ignition transformer of the Neva Lux boiler.

The electrical circuit of the ignition transformer is broken - Check the electrical circuit and contacts.

The burner block is clogged - Clean the burner block.

The electrical circuits of the gas supply regulator are broken - Check the electrical circuits and contacts.

Error 02- Overheating of water. The boiler is not working.

The heating system is clogged - Clean the heating system.

The thermal relay is faulty (normally closed at temperatures up to 90 °C) - Replace the thermal relay.

The filter in the heating system is clogged - Clean the filter.

The bypass valve is faulty or incorrectly installed - Check the correct installation of the bypass valve parts and, if necessary, replace it.

The pump or air bleed valve is faulty - Replace the pump or air bleed valve.

The pump relay on the electronic board is faulty - Replace the electronic board.

The gas supply regulator does not work - Replace the gas supply regulator.

The gas supply regulator is not configured - Adjust the gas supply regulator.

The electrical circuit of the thermal relay (overheating sensor) is broken - Check the electrical circuit and contacts.

Error 03- Lack of traction. The Neva Lux boiler is not working.

The chimney or air supply channel is clogged - Find out the cause of the blockage and eliminate it.

The tightness of the pressure switch tubes is broken - Replace the tubes.

Failure of the electrical circuit of the pressure switch - Check the electrical circuit and contacts.

The pressure switch is faulty (the pressure switch contacts should close when the pressure drop is 130 Pa or more) - Replace the pressure switch.

Condensation in the pressure switch tubes - Remove condensation from the pressure switch tubes.

Fan electrical circuit is broken - Check the electrical circuit and contacts.

The fan is faulty - Replace the fan.

Error 04- Insufficient water pressure in the heating circuit. The boiler is not working.

Reduced water pressure in the heating circuit - Bring the water pressure in the heating circuit to the recommended value.

Air lock in the heating system - Open the air bleed valve.

The water pressure sensor in the heating circuit is faulty - Replace the sensor.

The pump or bleed valve is faulty - Replace the pump or bleed valve.

The electrical circuit between the pressure sensor and the electronic board is broken - Check the contacts of the connectors in the control unit and on the sensor and the electrical circuit of the sensor.

Error 05- Failure of the heating circuit temperature sensor. The boiler is not working.

The heating circuit temperature sensor is faulty - Replace the heating circuit temperature sensor.

The electrical circuit “temperature sensor – electronic board” is broken - Check the electrical circuit and contacts.

Error 06- Sensor failure DHW temperature. The Neva Lux boiler operates only in heating mode.

The DHW temperature sensor is faulty - Replace the DHW temperature sensor.

The electrical circuit between the DHW temperature sensor and the electronic board is broken - Check the electrical circuit and contacts.

Error 07- Malfunction of the modulator coil of the gas supply regulator. The boiler is not working.

Broken gas regulator modulator coil - Replace the gas regulator (modulator coil resistance 80 Ohms).

The electrical circuit “modulator coil – electronic board” is broken - Check the electrical circuit and contacts.

Malfunctions of Neva Lux boilers without error code

Neva Lux boiler does not turn on

Lack of electricity - Contact the electricity supply service.

The fuse has blown - Replace the fuse on the board.

If water gets on the electronic board - Dry the board with warm air or leave it for two days in a dry place to completely evaporate the water.

Electronic board failure (RESET does not help) - Turn off the power and turn on the boiler again or replace the electronic board.

Popping in the burner

The minimum gas pressure and ignition power are incorrectly adjusted - Adjust the minimum gas pressure and ignition power.

Insufficient air supply - Clean the air intake pipe or duct.

A spark from the electrode of the spark plug jumps to the edge of the burner section or to the shell of the combustion chamber - Bend the spark plug or bend the shell of the combustion chamber, ensuring that the spark jumps into the area of ​​the holes in the nozzle of the burner section.

Dirty burner block - Clean the burner block.

Smell of gas

Gas leak - Check the entire gas circuit for leaks and eliminate the gas leak.

Little or no hot water output

Insufficient water pressure at the inlet to the hot water supply - Contact the housing and communal services service.

The water filter is clogged - Clean the filter on the DHW line.

The heat exchanger is clogged - Clean the heat exchanger.

The set hot water temperature is not maintained (too high)

High incoming water temperature - Increase water flow through the DHW circuit or dilute it hot water cold, without allowing a decrease in the flow through the DHW circuit.

Small water flow through the DHW circuit - Increase the water flow through the DHW circuit.

The Neva Lux boiler does not work in heating mode (but works in DHW mode)

The room thermostat jumper is missing - Install the room thermostat jumper.

The room thermostat jumper connecting the contacts is faulty - Replace the room thermostat jumper.

Defective room thermostat(if a thermostat is installed) - Replace the room thermostat.

The water temperature at the heating system inlet is below the set value

The heating circuit temperature sensor is faulty - Clean the temperature sensor from scale (if using an immersion temperature sensor), or replace the temperature sensor.

The boiler is in standby mode, the display shows the symbol “- -” and the boiler does not respond to pressing the control buttons

The supply voltage has gone beyond 190 ÷ 250 V - Restore the supply voltage within 190 ÷ 250 V. After 30 seconds, the boiler will automatically start in the mode in which it was before the voltage went beyond 190 ÷ 250 V.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

In the section on the question Boiler Neva Lux 8224. Constant error 03. Condensate accumulates in the pressure switch tubes. How to fix this problem. given by the author Vladimir the best answer is Need more detailed information about where it is located, external temperature, fuel (gas or diesel fuel), winter or summer, etc. And condensate from what (water, gas)?
What can be done to prevent condensation from collecting in pitot tubes? The Neva Lux 8224 boiler shuts down every year in January, showing error 03. Of course, I eliminate the condensation and start the boiler until the next accumulation of condensate, but I’m pretty tired of this problem. Help!

Answer from Yotas Shabanov[guru]
1. Check if the tap is completely closed
recharge.
2. If the make-up valve is closed all the way, then
It is possible that the make-up tap is not sealed.
Replace the water supply valve.
3. Check if the secondary heat exchanger is leaking.
4. Also check if the sensor is working properly
pressure and connectors of its contacts.
Another option: slightly opening the plug on the right side
at the top, in order to enter the combustion chamber
hit warm air and not
condensation formed in the presostat tubes.


In chapter Service, care and repair to the question Boiler Neva Lux 8224. Constant error 03. Condensation accumulates in the pressure switch tubes. How to fix this problem. given by the author Vladimir the best answer is Do you need more detailed information about where it is located, external temperature, fuel (gas or diesel), winter or summer, etc. And condensate from what (water, gas)?
What can be done to prevent condensation from collecting in pitot tubes? The Neva Lux 8224 boiler shuts down every year in January, showing error 03. Of course, I eliminate the condensation and start the boiler until the next accumulation of condensate, but I’m pretty tired of this problem. Help!

Answer from Yotas Shabanov[guru]
1. Check if the tap is completely closed
recharge.
2. If the make-up valve is closed all the way, then
It is possible that the make-up tap is not sealed.
Replace the water supply valve.
3. Check if the secondary heat exchanger is leaking.
4. Also check if the sensor is working properly
pressure and connectors of its contacts.
Another option: slightly opening the plug on the right side
at the top, in order to enter the combustion chamber
warm air got in and didn't
condensation formed in the presostat tubes.