Climatic modification t2 according to GOST 15150 69. Description of the most common climatic modifications: UHL1, U1, UHL2, U2, UHL3, U3, UHL4, U4 and others. Ambient temperature values ​​during product operation

Climatic modification t2 according to GOST 15150 69. Description of the most common climatic modifications: UHL1, U1, UHL2, U2, UHL3, U3, UHL4, U4 and others. Ambient temperature values ​​during product operation

Devices and various technical products are characterized by climatic design and placement category. In this article, we consider in detail the climatic version UHL.

You can download GOST 15150-69.

Deciphering the climatic version UHL:

  • At— temperate climatic region;
  • HL- cold climatic region.

Thus, the following conclusion can be drawn.

UHL- temperate and cold climate
Temperature from -60 С° to +40 С°

Expert opinion

Editor-in-chief of LinijaOpory

Pay attention to the similarities and differences in the climatic design depending on the category of accommodation.

UHL1 - accommodation category 1

Operating temperature for UHL1:

  • minimum - minus 60 С °;
  • maximum - plus 40 ° C.

Maximum operating temperature for UHL1:

  • minimum - minus 70 С °;
  • maximum - plus 45 С °.

Relative humidity for UHL1:

UHL2 - accommodation category 2

Working temperature for UHL2:

  • minimum - minus 60 С °;
  • maximum - plus 40 ° C.

Maximum operating temperature for UHL2:

  • minimum - minus 70 С °;
  • maximum - plus 45 С °.

Relative humidity for UHL2:

  • average annual — 75% at 15 С°;
  • maximum - 100% at 25 C °.

UHL3 - accommodation category 3

Accommodation category 3 provides operation in indoor premises without temperature control with natural ventilation (the temperature practically does not differ from outdoor temperature, there are no splashes and jets of water, a small amount of dust).

Working temperature for UHL3:

  • minimum - minus 60 С °;
  • maximum - plus 40 ° C.

Maximum operating temperature for UHL3:

  • minimum - minus 70 С °;
  • maximum - plus 45 С °.

Relative humidity for UHL3:

  • average annual — 75% at 15 С°;
  • maximum - 98% at 25 ° C.

UHL4 - accommodation category 4

Accommodation category 4 provides operation in indoor areas with heating and artificial ventilation (temperature control, no low temperatures, low dust concentration).

Working temperature for UHL4:

  • minimum - plus 1 С °;
  • maximum - plus 35 С °.

Maximum operating temperature for UHL4:

  • minimum - plus 1 С °;
  • maximum - plus 40 ° C.

Relative humidity for UHL4:

  • average annual — 60% at 20 С°;
  • maximum - 80% at 25 C °.

UHL5 - accommodation category 5

Working temperature for UHL5:

  • minimum - minus 10 С °;
  • maximum - plus 35 С °.

Maximum operating temperature for UHL5:

  • minimum - minus 10 С °;
  • maximum - plus 40 ° C.

Relative humidity for UHL5:

  • average annual — 90% at 15 С°;
  • maximum - 100% at 25 C °.
Post navigation

POLICY ON PERSONAL DATA

Personal data


This Personal Data Privacy Policy (hereinafter referred to as the Privacy Policy) applies to all information that TDNP LLC, located on the https://www.site domain name, can receive about the User while using the site.

  1. DEFINITION OF TERMS
  • 1.1. This Privacy Policy uses the following terms:
    • 1.1.1. "Site Administration" - authorized employees to manage the site, acting on behalf of TDNP LLC, who organize and (or) carry out the processing of personal data, and also determine the purposes of processing personal data, the composition of personal data to be processed, actions (operations), committed with personal data.
    • 1.1.2. "Personal data" - any information relating to a directly or indirectly identified or identifiable natural person (subject of personal data).
    • 1.1.3. "Processing of personal data" - any action (operation) or a set of actions (operations) performed using automation tools or without using such tools with personal data, including collection, recording, systematization, accumulation, storage, clarification (updating, changing), extraction, use, transfer (distribution, provision, access), depersonalization, blocking, deletion, destruction of personal data.
    • 1.1.4. “Confidentiality of personal data” is a mandatory requirement for the Operator or other person who has access to personal data to prevent their distribution without the consent of the subject of personal data or other legal grounds.
    • 1.1.5. "Site User (hereinafter referred to as the User)" - a person who has access to the Site via the Internet and uses the Site.
  1. GENERAL PROVISIONS
  • 2.1. The User's use of the site means acceptance of this Privacy Policy and the terms of processing the User's personal data.
  • 2.2. In case of disagreement with the terms of the Privacy Policy, the User must stop using the site.
  • 2.3. This Privacy Policy applies only to the site.
  • 2.4. The site administration does not verify the accuracy of personal data provided by the Site User.
  1. SUBJECT OF THE PRIVACY POLICY
  • 3.1. This Privacy Policy establishes the obligations of the Site Administration for non-disclosure and provision of a regime for protecting the confidentiality of personal data that the User provides at the request of the Site Administration when registering on the site.
  • 3.2. Personal data authorized for processing under this Privacy Policy is provided by the User by filling out the registration form on the Site and includes the following information:
    • 3.2.1. Username;
    • 3.2.2. the name of the User's company;
    • 3.2.3. email address (e-mail);
    • 3.2.4. user message;

4. PURPOSE OF COLLECTING USER'S PERSONAL INFORMATION

The Site Administration may use the User's personal data in order to establish feedback with the User, including sending notifications, requests regarding the use of the Site, the provision of services, processing requests and applications from the User.

5. METHODS AND TERMS OF PROCESSING PERSONAL INFORMATION

  • 5.1. The processing of the User's personal data is carried out without time limit, in any legal way, including in personal data information systems using automation tools or without using such tools.
  • 5.2. The User's personal data may be transferred to the authorized state authorities of the Russian Federation only on the grounds and in the manner established by the legislation of the Russian Federation.
  • 5.3. In case of loss or disclosure of personal data, the Site Administration informs the User about the loss or disclosure of personal data.
  • 5.4. The site administration takes the necessary organizational and technical measures to protect the User's personal information from unauthorized or accidental access, destruction, modification, blocking, copying, distribution, as well as from other illegal actions of third parties.

6. OBLIGATIONS OF THE PARTIES

  • 6.1. The user is obliged:
  • 6.1.1. Provide information about personal data necessary to use the Site.
  • 6.2. The site administration is obliged:
  • 6.2.1. Use the information received solely for the purposes specified in clause 4 of this Privacy Policy.
  • 6.2.2. Ensure that confidential information is kept secret, not disclosed without the prior written permission of the User, and also not to sell, exchange, publish, or disclose in other possible ways the transferred personal data of the User, with the exception of clause 5.2. of this Privacy Policy.
  • 6.2.3. Take precautions to protect the confidentiality of the User's personal data in accordance with the procedure usually used to protect this kind of information in existing business transactions.
  • 6.2.4. Block personal data relating to the relevant User from the moment the User or his legal representative or authorized body for the protection of the rights of subjects of personal data has applied or requested for the period of verification, in case of revealing false personal data or illegal actions.

7. CHANGES TO THE PRIVACY POLICY. APPLICABLE LAW

  • 7.1. The site administration has the right to make changes to this Privacy Policy. When making changes in the current version, the date of the last update is indicated. The new version of the Policy comes into force from the moment it is posted, unless otherwise provided by the new version of the Policy.
  • 7.2. The current edition is constantly available on the website https://www.site
  • 7.2. This Policy and the relationship between the User and the Site Administration arising in connection with the application of the Privacy Policy are subject to the law of the Russian Federation.

8. RESPONSIBILITY OF THE PARTIES

Under any circumstances, the responsibility of the Site Administration in accordance with Article 15 of the Civil Code of Russia is limited to 10,000 (ten thousand) rubles of the Russian Federation and is assigned to it if there is guilt in its actions.

9. FEEDBACK. QUESTIONS AND SUGGESTIONS

  • 9.1. The User has the right to send all suggestions or questions regarding this Privacy Policy to the address: 192283, St. Petersburg, Oleko Dundicha St., 10, k.1, kv.105

Modern manufacturers of machines, devices and other electrical products are required to adhere to a sufficiently large number of all kinds of regulatory documentation. Therefore, the offered goods will meet both the requirements of the buyer and the requirements of the quality control authorities. One of these conditions is the climatic performance.

Terminology

Familiarization with each question must begin with a study of the definitions used. Therefore, to begin with, we will try to give the most understandable formulation. So, climatic performance is a system of categories that includes the conditions for normal operation, transportation and storage of technical products in relation to the macroclimatic zoning of the surface of the globe. In other words, this term defines the conditions under which one or another electrical installation can be operated. In turn, binding to regions allows taking into account various climatic conditions.

Normative documents

Such a system is certified by the current legislation and is included in GOST 15150 "Climatic version". This standard applies to all types and varieties of instruments, machines and other technical products. All requirements of the above document are mandatory. Exceptions are only conditions marked "recommended" or "permissible". Like any other, GOST "Climatic performance" lists the areas of application of the regulatory documentation in question. Let's consider some of them.

1. This standard applies to both the design and manufacture of technical products. In addition, its observance is mandatory when drawing up assignments for the development and subsequent modernization, the creation of standards.

2. The climatic version of each product, as well as other technical parameters, must be kept within the established values.

3. Products manufactured by manufacturers are intended for storage, operation and transportation within the ranges of values ​​of the factors under consideration. In exceptional cases, they may contain a list of permissible deviations during operation.

4. In accordance with technical and economic feasibility, it is recommended to produce technical products suitable for operation in several macro-regions.

Currently, there are several categories that are based on the division of territories with similar environmental conditions. As a rule, the designation of a particular group is carried out using the appropriate letter marking. Let's take a closer look at each category.

U marking

In the Latin version, it is denoted by the letter "N". A similar climatic design is used for areas characterized by moderate environmental conditions. In addition, it should be remembered that technical products marked in this way may be subject to operation in a warm humid, hot dry, as well as very hot dry macroclimatic region, in which the average value for the annual absolute maximum air temperatures is above 40 degrees Celsius, and the humidity value is 80 percent or more. In this case, such characteristics should be observed for more than 12 hours every day for a two-month continuous period. In turn, a temperate climate has the following characteristics of atmospheric air: the annual absolute maximum temperature does not exceed forty degrees Celsius. From the foregoing, we can conclude that the climatic version U has the following temperature range: from -45 0 С to +40 0 С.

HL marking

In the Latin version, it is denoted by the letter "F". This group is characterized by cold climates. The annual absolute temperature minimum is -45 degrees Celsius. Electrical equipment with this type of marking is designed for operation within the following limits: -60 0 С - +40 0 С.

UHL marking

In the Latin version, it is denoted by the letters "NF". GOST "Climatic performance" refers to this category areas with moderate and cold environmental conditions. The temperature range of normal operation of products with such markings has the same limits as those of the previous group. In addition, products released with this category can be used in the same cases as products of group Y. For example, in hot and very hot dry climates, subject to the above conditions.

TV marking

In the Latin version, the letter designation is "TN". Such a climatic design is characterized by the operation of technical products in humid tropical environmental conditions. Atmospheric air has the following parameters: temperature over 20 degrees Celsius, humidity over 80 percent. A special condition is the preservation of the above requirements for more than 12 hours every day for two months continuously. The operating temperature limits for normal operation are +1 - +40 0 С.

Vehicle marking

In the Latin version, it is denoted by the letters "TA". Despite the similarity in name with the previous category, this group has many differences. The average value of the annual absolute maximum temperatures is +40 degrees Celsius. The range of such values ​​when used ranges from -10 to +50 0 С.

T marking

In the Latin version, it is denoted by the letter "T". Technical products marked with this marking are capable of normal operation in tropical climates.

Marking O

In the Latin version, it is denoted by the letter "U" and is a general climatic version. Products characterized in this way can be used in all macro-climatic regions of the earth, except for very cold environmental conditions. Temperature limits range from -60 0 С to +50 0 С.

Marking M

In the Latin version, it is also denoted by the letter "M". This category includes electrical products that are designed for normal operation in macroclimatic regions in a moderately cold marine-type environment.

TM marking

In the Latin version, it is denoted by the letters "MT" and includes territories characterized by tropical marine atmospheric air conditions. This category includes technical products intended for operation on coastal navigation vessels or any other vessels used only in the redistribution of these areas.

OM marking

In the Latin version, the letter designation is "MU". The presented group includes machines, devices and other products, the normal operation of which will be carried out in areas with both tropical and temperate cold climates. Thus, various vessels with unlimited navigation areas can be attributed to the category under consideration.

Marking B

In the Latin version, it is denoted by the letter "W". This group is quite specific, since it includes electrical products intended for widespread use, both on land and on water. Such a performance is called all-climatic. A feature is the impossibility of application only in areas characterized by very cold environmental conditions. Temperature limits for normal operation range from -60 to +50 degrees Celsius.

Locations

At present, electrical products are marked in a special way (climatic version and placement category are indicated). In this regard, the marking is a combination of an alphabetic and numerical designation. This allows customers to see at a glance whether the device is right for them or not.

Category 1

Technical products marked in this way are intended for outdoor use. Therefore, they are exposed to the totality of atmospheric factors. For example, climatic version U1.

Category 2

It assumes normal operation of equipment under a canopy or in rooms subject to fluctuations in the values ​​of atmospheric air parameters almost to the same extent as open space. For example, it can be a body.

Category 3

This group includes technical products that must be used only in enclosed spaces. At the same time, the latter should have the following features: the absence of artificial regulators of environmental conditions; exposure to dust and sand is significantly less than outdoors. Climatic version U3 can be used in rooms with thermal insulation made of metal, wood, concrete and other materials. Such objects can be classified as irregularly heated. Thus, the climatic version of U3 implies the absence of precipitation, direct sunlight, a significant reduction in the impact of wind and moisture.

Category 4

Equipment belonging to this group can be used in rooms characterized by artificial regulation of environmental parameters, well-ventilated underground buildings. It implies the absence of direct solar radiation, wind, moisture, sand.

Category 5

Such technical products can be used in rooms with high humidity values. For example, in underground rooms, in the soil, as well as on ships.

In PDF format (2.7 Mb)

1. GENERAL PROVISIONS

1.1. This International Standard shall be applied to the design and manufacture of products. In particular, it should be used in the preparation of technical specifications for the development or modernization of products, as well as in the development of state standards and specifications that establish requirements regarding the impact of climatic environmental factors for a group of products, and in the absence of these group documents, for certain types of products .

1.2. Products must maintain their parameters within the limits established by the technical specifications, standards or specifications during the service life and shelf life specified in the technical specifications, standards or specifications, after and (or) in the process of exposure to climatic factors, the values ​​of which are established by this standard.

Products are intended for operation, storage and transportation in the range from the upper to the lower values ​​of these climatic factors, while in addition to the ranges of climatic factors within which the operability of the products is ensured during operation, one or more narrower ranges of climatic factors can be set, within which provide a narrower range of parameter deviations (for example, higher accuracy of regulation or measurements). Within these ranges, several values ​​of the same factor may also be established when establishing requirements for various stages of operation or individual technical characteristics, for example, several values ​​​​of the upper and / or effective temperature for different resources or service lives.

Where necessary, the standards or specifications should indicate the permissible deviations of the parameters from their initial values ​​during operation.

1.3. For specific types or groups of products, the types of influencing climatic factors and their nominal values ​​​​are set depending on the operating conditions of the products in the relevant technical specifications, standards and specifications.

If there are documents establishing for groups of products the relationship between the values ​​of the factors specified in this standard and the conditions for the use of products, the instructions of these documents should be followed.

1.3 a. It is allowed to operate products in macroclimatic regions and (or) locations that differ from those for which the products are intended, if climatic factors during the operation period do not go beyond the nominal values ​​established for these products. For example, products of the UHL4 climatic modification type can be operated in the UHL2 conditions during the summer dry period.

It is allowed to operate the products in conditions where the values ​​of climatic factors go beyond the established nominal values, if deviations in the service life and (or) other parameters of the products are acceptable. At the same time, the admissibility of operation and its terms, the values ​​of climatic factors, the permissible deviations of the service life and (or) other parameters of the products, as well as (if necessary) additional requirements for the maintenance of products are established in the regulatory and technical documentation or agreed with the supplier of the products.

1.4. In accordance with economic and technical feasibility, it is recommended to manufacture products suitable for operation in several areas and (or) locations established by this standard.

1.5. Products can also be designed for operation in several macroclimatic regions and (or) locations, or for storage in several conditions alternately for different periods; in these cases, combinations of various operating or storage conditions with periods of stay under these conditions are established in the standards or specifications for products.

1.2-1.4. (Revised edition, Rev. No. 2).

1.6. Requirements for the impact of climatic factors of the environment in standards, specifications and other regulatory and technical documentation for products are established in accordance with Appendix 8.

2. CLIMATE VERSIONS AND PRODUCT CATEGORIES

2.1 a. Types of climates and macroclimates and criteria for their differentiation are given in paragraphs. 2.2-2.6 and Appendix 9.

2.1. Products are intended for operation in one or more macroclimatic regions, the selection criteria for which are indicated in paragraphs. 2.1a-2.6 and Appendix 9, and are manufactured in climatic versions (hereinafter referred to as versions) indicated in Table. 1.

Several macroclimatic regions can be combined into a group of macroclimatic regions (for example, UHL, T).

Table 1

Climatic versions of products

Designations*

alphabetic

digital

Russians

latin

Products intended for operation on land, rivers, lakes

For a macroclimatic region with a temperate climate**

For macroclimatic regions with temperate and cold climates**

For a macroclimatic region with a humid tropical climate***

For a macroclimatic region with a dry tropical climate***

For macroclimatic regions with both dry and humid tropical climate***

For all macroclimatic regions on land, except for a macroclimatic region with a very cold climate (general climatic version)

Products intended for operation in macroclimatic regions with maritime climate

For a macroclimatic region with a moderately cold maritime climate

For a macro-climatic region with a tropical maritime climate, including coastal vessels or other vessels intended for navigation only in this region

For macroclimatic regions with both moderately cold and tropical maritime climates, including ships with an unlimited navigation area

Products intended for operation in all macroclimatic regions on land and at sea, except for a macroclimatic region with a very cold climate (all climatic versions)

* In parentheses are the designations previously adopted in the technical documentation of some CMEA countries.

** Products in U and UHL versions can be operated in warm humid, hot dry and very hot dry climatic regions in accordance with GOST 16350, in which the average of the annual absolute maximum air temperatures is above 40 ° C and (or) a combination of temperatures equal to or above 20 °C, and relative humidity equal to or above 80%, observed more than 12 hours a day for a continuous period of more than two months a year.

Specific types or groups of exported or other products for a macroclimatic subregion with a warm temperate climate are allowed to be manufactured in the climatic version TU, if the design differences between the products of this version and the products of the climatic version U are technically and economically justified.

*** The specified versions may be designated by the term "tropical version".

**** If the main purpose of the products is operation in an area with a cold climate and it is not economically feasible to use them outside this area, the designation HL (F) is recommended instead of the UHL designation.

2.2. A macroclimatic region with a temperate climate includes areas where the average annual absolute maximum air temperature is equal to or below plus 40°C, and the average annual absolute minimum air temperature is equal to or above minus 45°C (in accordance with Appendix 9).

It is allowed to single out a macroclimatic subregion with a warm temperate subtype of macroclimate from a macroclimatic region with a temperate climate, for which the average of the annual absolute minimum air temperatures is equal to or higher than minus 25 °C (in accordance with Appendix 9).

(Changed edition, Rev. No. 3, 4).

2.3. A macroclimatic region with a cold climate includes areas in which the average of the annual absolute minimum air temperatures is below minus 45 ° C (in accordance with Appendix 9).

The boundaries of the macroclimatic region with a cold climate on the territory of the Russian Federation are given in mandatory Appendix 2. The cold climate region is indicated on the map in Appendix 6.

By agreement with the customer, it is allowed to supply products designed for a temperate climate to areas within 50 km from the southwestern and southeastern borders of a macroclimatic region with a cold climate on the territory of the Russian Federation.

Products placed on mobile installations intended for deliveries to the coast of the Okhotsk (to the north of the mouth of the Uda River) and the Bering Seas (with the exception of the Kamchatka Peninsula) must be manufactured in the HL version.

The macroclimatic region with an Antarctic cold climate includes areas where the average minimum temperature is below minus 60°C (Central Antarctica).

(Revised edition, Rev. No. 4).

2.4. In accordance with Annex 9, a macroclimatic region with a humid tropical climate includes areas for which the values ​​of the combination "average annual relative humidity-average annual temperature" correspond to classification groups 1 and 2 according to features. 1 app 9.

A macroclimatic region with a dry tropical climate includes areas in which the average of the annual absolute maximum air temperatures is above 40 ° C and in which the values ​​of the combination "average annual relative humidity-average annual temperature" correspond to classification group 5 according to features. 1 of Appendix 9, as well as a climatic region with a transitional climate in accordance with Appendix 9. A list of countries classified as regions with a humid and dry tropical climate is given in Appendix 3.

The macroclimatic regions of the globe are shown on the map in Appendix 6.

(Revised edition, Rev. No. 4).

2.5. A macroclimatic region with a moderately cold maritime climate includes seas, oceans and coastal areas within the direct influence of sea water located north of 30° north latitude or south of 30° south latitude (in accordance with Appendix 9).

(Revised edition, Rev. No. 4).

2.6. A macro-climatic region with a tropical maritime climate includes seas, oceans and coastal areas within the direct influence of sea water, located between 30 ° north latitude and 30 ° south latitude (in accordance with Appendix 9).

(Revised edition, Rev. No. 4).

2.6a. Characteristics of climate types and macroclimates in terms of air temperature and humidity are given in Appendix 11.

Data on the correspondence between the types of climates and macroclimates according to this standard and the types and groups of climates according to IEC international standards are given in Appendix 12.

(Introduced additionally, Rev. No. 4).

2.7. Products in the versions according to clause 2.1, depending on the location during operation in the air at altitudes up to 4300 m (including underground and under water), are manufactured according to the product placement categories (hereinafter referred to as product categories) indicated in Table. 2.

table 2

Characteristic

Designation

Characteristic

Designation (decimal)

For outdoor operation (impact of a combination of climatic factors characteristic of a given macroclimatic region)

For storage during operation in rooms of category 4 and work both in conditions of category 4 and (for a short time) in other conditions, including outdoors

For operation under a canopy or in rooms (volumes) where fluctuations in temperature and humidity do not differ significantly from fluctuations in the open air and there is relatively free access to outside air, for example, in tents, bodies, trailers, metal rooms without thermal insulation, as well as in a shell complete product category 1 (no direct exposure to solar radiation and precipitation)

For operation as built-in elements inside complete products of categories 1; 1.1; 2, the design of which excludes the possibility of moisture condensation on built-in elements (for example, inside radio-electronic equipment)

For operation in enclosed spaces (volumes) with natural ventilation without artificially controlled climatic conditions, where temperature and humidity fluctuations and exposure to sand and dust are significantly less than outdoors, for example, in metal with thermal insulation, stone, concrete, wooden rooms ( no exposure to precipitation, direct solar radiation; significant reduction in wind; significant reduction or absence of exposure to scattered solar radiation and moisture condensation)

For operation in irregularly heated rooms (volumes)

For operation in rooms (volumes) with artificially controlled climatic conditions, for example, in closed heated or cooled and ventilated industrial

For use in air-conditioned or partially air-conditioned rooms

and others, including well-ventilated underground rooms (no exposure to direct solar radiation, precipitation, wind, sand and dust from outdoor air; no or significant reduction in the impact of scattered solar radiation and moisture condensation)

For operation in laboratory, capital residential and other similar premises

For operation in premises (volumes) with high humidity (for example, in unheated and unventilated underground premises, including mines, basements, in the soil, in such ship, ship and other premises in which a long-term presence of water or frequent condensation of moisture on walls and ceiling, in particular, in some holds, in some workshops of textile, hydrometallurgical industries, etc.).

For operation as built-in elements inside complete products of categories 5, the design of which excludes the possibility of moisture condensation on built-in elements (for example, inside radio-electronic equipment)

For products intended for operation only in a non-air environment and (or) at atmospheric pressure less than 53.3 kPa (400 mm Hg), including at altitudes over 4300 m, the concept of product category is not used for all stages of operation. If the same product is intended for operation both in air at altitudes up to 4300 m, and in a non-air environment and (or) at atmospheric pressure less than 53.3 kPa (400 mm Hg), including at altitudes more than 4300 m, then the concept of product category is used only for the stage of operation in the air at altitudes up to 4300 m.

Aircraft, as well as products intended for operation at altitudes of more than 1000 m at reduced atmospheric pressure (including products intended for operation both at altitudes of more than 1000 m and at altitudes up to 1000 m) are manufactured in groups depending on the reduced atmospheric pressure. atmospheric pressure in accordance with Appendix 7, Table. 1.

The product category designation may be used to designate the place of placement and placement of parts and surfaces of products or structures (for example, a closed heated and ventilated room can be designated "placement category 4" or "category 4 room").

The combination of version, category and reduced pressure group is called "climatic version" (for example, UHL4 climatic version or UHL2O4a climatic version). In the designation of the type of climatic modification of the product, the designation of the type of atmosphere for operation in which the product is intended is added, if this is indicated in the standards or technical specifications for the product.

Climatic conditions (a set of values ​​of climatic factors), normalized in this standard for any particular type of climatic performance, denote

"conditions.........." (for example, UHL4 conditions).

type of climatic modification

For products designed before 07/01/79, it is allowed not to change the previously established designations of climatic modifications of products in the following cases:

    if the products are scheduled to be discontinued before 07/01/85 and will not be produced as spare parts in the future;

    if it is necessary to use the available equipment and accompanying documentation made in a typographical way, but no later than 01.07.85.

(Revised edition, Rev. No. 4).

2.7a. They do not manufacture products of the types of climatic modification indicated in the first line of the table. 2a, since these products meet the requirements for products of types of climatic modification, given respectively in the second row of Table. 2a.

Table 2a

Line number

Types of climatic modification

U4.1

U4.2

TU5

T4.1

T4.2

TV5

TS2.1

O3.1

TM4.1

OM3.1

OM5

HL4

HL4.1

HL4.2

OM4.1

TU4

TU4.1

TU4.2

UHL4

UHL4.1

UHL4.2

O4.1

O4.2

TS2

B3.1

B4.1

OM.4

(Introduced additionally, Rev. No. 4).

2.8. In the conditional designation of the type (brand) of the product, in addition, after all the designations related to the modification of the product, letters and numbers are entered that indicate the type of climatic modification of the product. For example, an electric motor of type AO2-21-4 in version T for placement category 2 is designated AO2-21-4T2.

The designation of the type of climatic modification is indicated in all types of documentation, including operational documentation, as well as on the nameplate (label), in which the type (brand) of the product must be indicated.

It is allowed not to enter the type of climatic version in the symbol of the type (brand) of the product in the cases specified in subparagraphs a, b, c. In this case, the type of climatic version must be specified in the standards or technical conditions, operational documentation. The designation may not include:

b) the type of climatic modification of one of the variants of products, which, as a rule, is common for the entire industry or a group of products of the industry, if the products are manufactured in several types of climatic modification;

For products that do not have a serial number, plates and individual differences (for example, electronic equipment, electrical installation products), it is allowed to apply symbols or a symbol on a non-removable part.

The designation of the types of climatic performance of products manufactured in accordance with clause 1.4 must include either a combination of performance and category providing the most severe operating conditions, or (if this combination cannot be established) several performances and categories for which the products are intended (combined designation). For example, an electric motor of type AO2-21-4, designed for categories 2, 3, 4, UHL version (category 2 is the most severe for this product), designate AO2-21-4UHL2; the same electric motor, designed to operate additionally in category 5 conditions, is designated AO2-21-4UKHL2.5 in category 4 conditions of version O-AO2-21-4UKHL2O4 (in the last two examples, category 2 is the most severe for this product in terms of the lower temperature value, category 5 or conditions O4 - by air humidity).

For products that meet the requirements of clause 5.2, for those cases where the range of nominal values ​​for any factor is narrower than the range of normal operating values, as well as for products whose operating conditions are established according to clause 1.5, to the designation of the type of climatic modification (or categories) add a * sign.

For products that meet the requirements of clause 5.2, for those cases where the range of nominal values ​​for any climatic factor is wider than the range of normal operating values, and narrower ranges of values ​​of other climatic factors are not provided, a sign * is added to the designation of the type of climatic modification *. This symbol is not added to the designation of groups of products specially designed in accordance with clause 5.2 for use as built-in elements for complete products, where the temperature inside the structure is higher than outside.

If the product consists of several components that do not have a common shell and operate under conditions of different categories, the category designation of the product as a whole is taken according to the components that perform the main function; in the standard or technical specifications for the product, categories of other components may also be indicated.

In the designation of products that meet the requirements of clause 5.10, and products intended for operation only in a non-air environment, the sign * is used instead of designating the type of climatic modification. For example, AO2-21-4*.

In the designation of products intended for operation in water, the * sign is used instead of the category designation. For example, AO2-21-4OM *.

It is allowed to separate the designation of climatic design with a line from the main designation of products, if the absence of a line leads to a distortion of the main designation.

It is allowed not to enter the designations of types of climatic modification in the symbol of types of products in technical documentation (except for technical specifications and operational documentation) developed before January 1, 1972.

For materials and semi-finished products, the designation of the type of climatic modification or only the climatic modification is established in cases not specified in subparagraph a, while the designation of the category as part of the designation of the type of climatic modification can be installed in cases where the material is used for the direct manufacture of parts of products.

2.7, 2.8. (Changed edition, Rev. No. 2, 4). conditions are set in standards or specifications for products.

(Introduced additionally, Amendment No. 2).

3. NORMAL VALUES OF ENVIRONMENTAL CLIMATIC FACTORS DURING OPERATION AND TESTS

3.1. The normal values ​​​​of climatic factors of the external environment during the operation of products are taken equal to the values ​​\u200b\u200bspecified in paragraphs. 3.2-3.14, 3.16. These values ​​apply to the operation of products at altitudes up to 1000 m, unless otherwise indicated in the paragraphs of this section.

3.2. The values ​​of the ambient air temperature are given in Table. 3.

Table 3

Product execution

Air temperature value during operation, °C

Working

Limit working

top

bottom

top

bottom

U, TU

1; 1.1; 2;

2.1; 33.15; 5.1

40+40+35

45*-10*****-5

45+45+35

50*-10*****-5

HL

1; 1.1; 2;

2.1; 33.15; 5.1

40+40+35

60-10*****-10

45+45+35

70-10*****-10

UHL

1; 1.1; 2;

2.1; 33.144.14.25; 5.1

40+40+35+25+35+35

60-10*****+1+10+10-10

45+45+40+40+40+35

70-10*****+1+1+1-10

TV

1; 1.1; 2; 2.1;

3; 3.144.14.25; 5.1

40+40+25+45+35

1+1+10+10+1

45+45+40+45+35

1**+1+1+10+1

T, TS

1; 1.1; 2;

2.1******;3; 3.14*******4.1*******4.2*******5; 5.1

50******** +45+25+45+35

10 +1+10+10+1 +60

55+40+45+35

10*** +1+1+10+1

1; 1.1; 2; 2.144.14.25; 5.1

50********+45+25+45+35

60+1+10+10-10

60+55+40+45+35

70+1+1+1-10

1; 1.1; 2

2.1; 3; 5; 5.14; 3.14.14.2

40+40+35+40

40****-10*****+15+1

45+40+40+40

40-10*****+1+1

TM

1; 1.1; 2;

2.1; 3; 5; 5.144.14.2

45+45+25+45

1+1+10+1

45+45+40+45

1+1+1+1

OM

1; 1.1; 2; 2.1;

3; 5; 5.14; 3.14.14.2

45+45+35+40

40****-10*****+15+1

45+45+40+40

40-10*****+1+1

1; 1.1; 2; 2.1; 33.144.14.25; 5.1

50********+50********+45+25+45+45

60-10*****-10*****+10+1-40

60+60+55+40+45+45

70-10*****-10*****+1+1-40

* For products that, according to operating conditions, may have interruptions in operation at occasionally occurring temperatures below minus 40 ° C, the lower operating temperature value is allowed, in technically justified cases, to be taken equal to minus 40 ° C.

For performance specifications, the lower operating temperature value is assumed to be minus 25°С, the lower limit operating temperature value is minus 30°С.

** For some areas with a subtropical climate, the value is assumed to be minus 10°С.

*** For some areas in China, Turkey, Afghanistan, the value is taken equal to minus 20°С.

**** For ships not used in areas of the Arctic Ocean in winter, the lower operating temperature is assumed to be minus 30°C.

***** For operation in a non-operating state (for operational storage and transportation), the value is taken the same as for category 3, and for the type of climatic modification B4, as for the type of modification OM3.

****** For execution T.

******* For TS version.

******** For some points in the Central Sahara, the temperature is assumed to be 55°C. It is allowed to set a temperature of 45°C for products developed before 07/01/89 and not supplied to the regions of Iraq, the countries of the Arabian Peninsula, Southern Iran and Central Sahara.