Ariston double-circuit gas boiler: instructions, technical specifications. Gas boiler Ariston (Ariston) Double-circuit gas heating boilers Ariston instructions

Ariston double-circuit gas boiler: instructions, technical specifications.  Gas boiler Ariston (Ariston) Double-circuit gas heating boilers Ariston instructions
Ariston double-circuit gas boiler: instructions, technical specifications. Gas boiler Ariston (Ariston) Double-circuit gas heating boilers Ariston instructions

Ariston's product range today includes 3 models of double-circuit gas boilers to provide residential buildings heating and hot water supply.

For areas of less than 200 m2, the BS II model is offered, and for areas of 200-350 m2 BS II, EGIS PLUS and CLAS B.

The advantage of the devices is the cost of heat production compared to all other types of boilers. The disadvantage is the need for a central gas supply system and a constant supply of electricity. Gas boilers are suitable for heating and hot water supply in residential apartments and country houses

, being a cheaper alternative to central heating.

General characteristics of boilers


operating modes.

Line of models II – wall-mounted gas boiler for heating and hot water supply in apartment buildings. The boiler has a compact design, low weight and two reliable separate heat exchangers:

BS II 15 FF BS II 24 FF BS II 24 CF
The combustion chamber closed open
11-15 11-25,8 11,2-25,8
11-28 11-27 11-27
89,6 93,8 91,9
89,3 93,6 91,2
35-85
DHW circuit temperature, °C 36-60
13,6
9,7
Weight, kg 30
Price, rub 36 500 42 000 39 000

Model CLASB It has wall version and a built-in 40 liter boiler from of stainless steel. The device is designed for high water consumption in the DHW circuit, combining the functions of a storage and instantaneous water heater.

The model is equipped with a digital display for comfortable control:

CLAS B 24 CF CLAS B 24FF CLAS B 30FF
The combustion chamber open closed
Thermal power (heating circuit, kW 11-25 11-25,8 13-31,3
Thermal power (DHW circuit), kW 11-27 11-27 13-31,3
Efficiency at 100% thermal power, % 91,9 93,8 93,6
Efficiency at 30% thermal power, % 91,2 93,6 93,2
Heating circuit temperature, °C 35-82
DHW circuit temperature, °C 40-65
Capacity of the DHW circuit when heating water at 25 °C, l/min 22,8 25,2
Capacity of the DHW circuit when heating water at 35 °C, l/min 16,3 18
Weight, kg 52 55
Price, rub 84 000 87 700 90 000

Model EGISPLUS available in 24 kW version and is a worthy continuation of the BS II series.

The boiler is wall-mounted and equipped with a comfortable digital control panel, the price does not exceed BS II:

EGIS PLUS 24 CF EGIS PLUS 24 FF
The combustion chamber open closed
Thermal power (heating circuit, kW 11,2-25,8 11-25,8
Thermal power (DHW circuit), kW 11,2-25,8 11-25,8
Efficiency at 100% thermal power, % 91,9 93,8
Efficiency at 30% thermal power, % 91,2 93,6
Heating circuit temperature, °C 35-85
DHW circuit temperature, °C 36-60
Capacity of the DHW circuit when heating water at 25 °C, l/min 13,6
Capacity of the DHW circuit when heating water at 35 °C, l/min 9,7
Weight, kg 30
Price, rub 35 500 39 900

Device selection

When choosing a device, you must be guided by the following criteria:

  • Area of ​​the heated room in m2. It is necessary to select a boiler based on 1 kW of thermal power per 10 m 2 of room. At the same time, it is necessary to understand that this perfect option and taking into account the heat loss of the living space, average annual air temperatures at the installation site and the radiators used, it is necessary to enter correction factor. For a preliminary assessment, we recommend using any online calculator that takes into account the above factors and also makes adjustments for the location of the walls (windward or not), ceiling height, and type of windows.
  • Need for hot water. For high consumption, it is wise to choose the CLAS B model with a built-in boiler, which is more economical.
  • Boiler installation location. For water heating units with open camera combustion requires room equipment forced ventilation, since the combustion air comes directly from the room. Since devices with an open combustion chamber are designed to remove combustion products through a chimney with natural draft, it is necessary to provide for the installation location of the chimney and chimneys.

    IMPORTANT! It is not allowed to pass chimneys through structures made of flammable material.


Gas boiler design

Boiler malfunctions

Most problems that arise can be prevented during the installation of the boiler. Here is a list of the main malfunctions, their causes and measures to prevent device failure:

  • The main reason is incorrect commissioning and incorrect device settings. Carefully reading the instructions often solves the problem. If necessary, you should involve a qualified specialist who will carry out commissioning and provide instructions on how to use the device. When choosing a model, contact the company , which will pick up necessary equipment
  • , based on your requirements; Trust the installation and commissioning of the device
  • a qualified specialist; operation manual;
  • Do not neglect periodic preventive examinations and servicing of equipment;
  • For any frequently recurring fault, turn off the boiler and call a qualified specialist;
  • Trust repairs and spare parts supply only from a certified organization.

On this page you can find and download instructions for Gas wall-mounted boilers Ariston in pdf format.

      Gas wall mounted Ariston boilers series GENUS 24 FF, GENUS 28 FF, GENUS 36 FF, GENUS 24 CF, GENUS 28 CF. User manual. Language: RU, RO | pdf 786.93 Kb

      Ariston gas wall-mounted boilers of the GENUS 24 CF, GENUS 28 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.09 Mb

      Ariston gas wall-mounted boilers of the GENUS 24 FF, GENUS 28 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.07 Mb

      Gas wall-mounted boilers Ariston series GENUS 24 FF, GENUS 28 FF. Installation and maintenance instructions. Language: RU, RO | pdf 5.05 Mb

      Gas wall-mounted boilers Ariston series GENUS 24 CF, GENUS 28 CF. Installation and maintenance instructions. Language: RU, RO | pdf 3.14 Mb

      Gas wall-mounted boilers Ariston GENUS 36 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 893.17 Kb

      Gas wall-mounted boilers Ariston GENUS 36 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.00 Mb

      Ariston gas wall boilers of the GENUS 24 CF, GENUS 28 CF, GENUS 24 FF, GENUS 28 FF, GENUS 35 FF series. User manual. Language: RU, RO | pdf 7.32 Mb

      Wall mounted single-circuit boilers CLAS System 24 FF, CLAS System 28 FF, CLAS System 32 FF. Installation and maintenance instructions. 2008 | pdf 4.71 Mb

      Gas wall-mounted single-circuit boilers CLAS System 15 FF, CLAS System 24 FF, CLAS System 28 FF, CLAS System 32 FF, CLAS System 15 CF, CLAS System 24 CF, CLAS System 28 CF. User manual. 2008 | pdf 1.24 Mb

      Gas wall-mounted double-circuit boilers EGIS 24 CF. Installation and maintenance instructions. 2008 | pdf 1.01 Mb

      Gas wall-mounted double-circuit boilers EGIS 24 FF. Installation and maintenance instructions. 2008 | pdf 1.24 Mb

      Gas wall-mounted double-circuit boilers EGIS 24 FF, EGIS 24 CF. User manual. 2008 | pdf 497.92 Kb

      Gas wall-mounted boilers Ariston series BS 24 FF, BS 24 CF. User manual. Language: RU, PL | pdf 439.96 Kb

      Gas wall-mounted boilers Ariston BS 24 CF series. Installation and maintenance instructions. Language: RU, PL | pdf 1.86 Mb

      Gas wall-mounted boilers Ariston BS 24 CF series for heating and hot water supply. Passport. Language: RU, PL | pdf 1.05 Mb

      Gas wall-mounted boilers Ariston BS 24 FF series for heating and hot water supply. Passport. Language: RU, PL | pdf 1.08 Mb

      Gas wall-mounted boilers Ariston BS 24 FF series. Installation and maintenance instructions. Language: RU, PL | pdf 2.33 Mb

      Gas wall-mounted boilers Ariston BS II 15 FF series. User manual. Language: RU, UA, RO | pdf 228.38 Kb

      Gas wall-mounted boilers Ariston BS II 15 FF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.71 Mb

      Gas wall-mounted boilers Ariston BS II 15 FF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1012.93 Kb

      Gas wall-mounted boilers Ariston BS II 24 FF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.88 Mb

      Gas wall-mounted boilers Ariston BS II 24 FF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1018.39 Kb

      Gas wall-mounted boilers Ariston BS II 24 CF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1005.51 Kb

      Gas wall-mounted boilers Ariston BS II 24 CF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.38 Mb

      Gas wall-mounted boilers Ariston series BS II 24 FF, BS II 24 CF. User manual. Language: RU, UA, RO | pdf 246.76 Kb

      Gas wall-mounted boilers Ariston series CLAS 24 FF, CLAS 28 FF, CLAS 24 CF. User manual. Language: RU, RO | pdf 661.98 Kb

      Gas wall-mounted boilers Ariston CLAS 24 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.28 Mb

      Gas wall-mounted boilers Ariston CLAS 24 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1005.77 Kb

      Gas wall-mounted boilers Ariston series CLAS 24 FF, CLAS 28 FF for heating and hot water supply. Installation and maintenance instructions. Language: RU, RO | pdf 2.78 Mb

      Gas wall-mounted boilers Ariston series CLAS 24 FF, CLAS 28 FF for heating and hot water supply. Passport. Language: RU, RO | pdf 1.13 Mb

      Gas wall-mounted boilers Ariston series CLAS B, CLAS B Premium: CLAS B 24 CF, CLAS B 24 FF, CLAS B 30 FF, CLAS B Premium 24, CLAS B Premium 35. Operating instructions. Language: RU, PL, CZ, RO, HU | pdf 2.52 Mb

      Gas wall-mounted boilers Ariston CLAS B 24 CF series. Installation and maintenance instructions. Language: RU, PL, CZ, RO, HU | pdf 7.20 Mb

      Gas wall-mounted boilers Ariston CLAS B 24 CF series for heating and hot water supply. Passport. Language: RU, PL, CZ, RO, HU | pdf 1.09 Mb

      Gas wall-mounted boilers Ariston series CLAS B 24 FF, CLAS B 30 FF for heating and hot water supply. Installation and maintenance instructions. Language: RU, PL, CZ, RO, HU | pdf 8.84 Mb

      Gas wall-mounted boilers Ariston series CLAS B 24 FF, CLAS B 30 FF for heating and hot water supply. Passport. Language: RU, PL, CZ, RO, HU | pdf 1.15 Mb

      Ariston gas wall boilers of the CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF, CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF series. User manual. Language: RU, RO | pdf 373.49 Kb

      Gas wall-mounted boilers Ariston series CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF. Installation and maintenance instructions. Language: RU, RO | pdf 1.87 Mb

      Ariston gas wall boilers of the CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 987.40 Kb

      Gas wall-mounted boilers Ariston series CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF. Installation and maintenance instructions. Language: RU, RO | pdf 2.60 Mb

      Ariston gas wall boilers of the CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 990.97 Kb

      Ariston gas wall boilers of the CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF, CLAS EVO SYSTEM 15 CF, CLAS EVO SYSTEM 24 CF series. User manual. Language: RU | pdf 306.18 Kb

      Ariston gas wall boilers of the CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF series. Installation and maintenance instructions. Language: RU | pdf 2.33 Mb

      Ariston gas wall boilers of the CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF series for heating and hot water supply. Passport. Language: RU | pdf 946.87 Kb

      Gas wall-mounted boilers Ariston series EGIS PLUS 24 FF, EGIS PLUS 24 CF. User manual. Language: RU, RO | pdf 204.57 Kb

      Gas wall-mounted boilers Ariston EGIS PLUS 24 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.29 Mb

      Gas wall-mounted boilers Ariston EGIS PLUS 24 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 973.91 Kb

      Ariston gas wall-mounted boilers of the EGIS PLUS 24 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 934.35 Kb

      Gas wall-mounted boilers Ariston EGIS PLUS 24 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 1.69 Mb

      Ariston gas wall boilers of the GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF, GENUS EVO 24 CF, GENUS EVO 30 CF series. User manual. Language: RU, RO | pdf 446.18 Kb

      Ariston gas wall boilers of the GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 991.20 Kb

      Ariston gas wall-mounted boilers of the GENUS EVO 24 CF, GENUS EVO 30 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1019.57 Kb

      Ariston gas wall boilers of the GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.72 Mb

      Ariston gas wall boilers of the GENUS EVO 24 CF, GENUS EVO 30 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.19 Mb

Gas still remains the cheapest type of fuel. Accordingly, the most cheap heating it turns out exactly on natural gas. True, installing a gas boiler is associated with certain difficulties - the premises must comply with fire safety standards.

To install powerful gas boilers, a separate room is required

Gas boiler installation standards

To avoid any troubles when putting the gas boiler into operation, you must select the installation location in accordance with current standards. The installation of a gas boiler in a private house (single-apartment or semi-detached) is regulated by SNiP 02/31/2001, and the installation rules in apartment buildings are prescribed in SNiP 2.08.01.

For private houses

According to the standards, a gas boiler can be installed in a ventilated room, which is located:

  • on the first floor of the house;
  • in the basement or basement;
  • in the attic:
  • gas boilers power up to 35 kW (according to MDS 41.2-2000 up to 60 kW) can be installed in the kitchen.

There are currently two standards in force regarding the installation of boilers in the kitchen. According to one document, heating devices with a power of no more than 35 kW can be placed, according to another - no more than 60 kW. And we are only talking about heating devices. Gas stoves or other equipment using gas is not taken into account.

What to do? You need to find out what standards your GorGaz adheres to. After all, it is their representatives who will accept the equipment into operation. Actually, the designer should tell you all the details, but it is also advisable to know this - you will need to prepare the room for installation.

Where to put

Now about where and how to place gas equipment different power. We will talk about gas boilers and their power is summed up:

  • with a power of up to 150 kW inclusive - in a separate room on any floor, including the basement and basement;
  • from 151 kW to 350 kW inclusive - in a separate room of the first, basement or ground floor, as well as in a separate attached room.

More powerful installations are not used in private homes.

Requirements for kitchens in which a gas boiler is installed

When placing a flow-through in the kitchen gas water heater or heating boiler on gas with a power of up to 60 kW, the room must meet the following standards:


There is one more thing that is not specified in the standards, but which exists: installing a gas boiler is allowed only in a room with doors. In the light latest trends- removing partitions and making doors instead - this could be a problem. Without a door, the permit will not be signed. The solution is to put or . Another option - glass doors. They do not “load” the interior, but they are perceived exactly as doors.

All these requirements must be met. If there are violations, they simply won’t sign the acceptance certificate for you.

Requirements for individual premises

They are similar, but there are some differences:

  • Ceiling height - at least 2.5 m;
  • The volume and area of ​​the room are determined by ease of maintenance, but should not be less than 15 m3.
  • Walls leading to adjacent rooms must have a fire resistance limit of 0.75 hours and zero limit for the spread of fire through the structure (brick, concrete, building blocks).
  • An exhaust hood with the same requirements: for outflow - three times exchange, for inflow in the same volume, plus air for combustion.
  • The room must have a window. The glass area is at least 0.03 m2 per cubic meter of volume.

If equipment is installed with a power of 150 kW or more, one of the prerequisites is the presence of access to the street. A second exit can be equipped - to a utility room (not residential). This could be a pantry or a hallway. Doors must be fireproof.

Please note that when calculating windows, the glass area is considered, not the size of the window opening. Moreover, in some cases they require at least one glass with an area of ​​at least 0.8 square meter. If enlarging the windows is problematic, you can make a similar window in the door (the regulations do not say that it must be in the wall).

How to attach boiler rooms

Sometimes it is not possible to allocate a separate room in the house. In this case, the boiler room is added. Standards for ceiling height, volume, glazing and ventilation remain the same as for separate rooms, only more specific norms are added:


Please note that the extension must be registered. No one will give you gas without official documents. And one more thing: when designing it, lay down all the standards without deviations, otherwise they won’t accept it. If the installation of a gas boiler is planned in an existing room, they may turn a blind eye to some deviations or offer some compensation (if there is a lack of volume or height of the ceilings, they may be asked to increase the glazing area). For newly constructed buildings (and extensions too) there are no such discounts: they must include all standards.

Combined kitchens

Today it has become fashionable to have or. It turns out to be a single large space, in which it is easy to implement design ideas. But the gas service regards such premises as residential and prohibits the installation of gas equipment.

It will not be possible to solve the problem with a studio apartment, but with a combined apartment there is a solution. If you are just planning to combine the kitchen and living room, when preparing the documents, call the resulting room kitchen-dining room. This premises is not residential, so there will be no restrictions. If the papers have already been completed, you can try to redo them or go the other way - install sliding partition. True, in this case, the documents will need to be redone.

Place for installing a gas boiler

If we talk specifically about apartments, then gas boilers are installed in them, mostly in the kitchens. There are all the necessary communications: running water, gas, a window and an exhaust hood. It remains only to determine appropriate place for the boiler. For this installation, wall-mounted (mounted) boilers are used. They are installed on several hooks fixed to the walls (usually included in the kit).

As for installation in other areas of the apartment or house, as a rule, none of them meet the requirements. For example, there is no window in the bathroom natural light, the corridor usually does not fit in size - there is not enough tolerance from the corners or to the opposite wall, usually there is no ventilation at all or it is insufficient. The problem with storage rooms is the same - there is no ventilation and windows, there is not enough volume.

If there is a staircase in the house to the second floor, the owners often want to place the boiler under the stairs or in this room. In terms of volume, it usually passes, but in terms of ventilation it will have to be very powerful - the volume is considered to be at two levels and it is necessary to ensure its threefold exchange. This will require several pipes (three or more) of a very large cross-section (at least 200 mm).

Once you have decided on the location for installing the gas boiler, all that remains is to find a place for it. It is selected based on the type of boiler (wall-mounted or floor-standing) and the manufacturer’s requirements. The technical data sheet usually specifies in detail the distances from the wall on the right/left, the installation height relative to the floor and ceiling, as well as the distance from the front surface to the opposite wall. U different manufacturers they may vary, so it's worth reading the manual carefully.

Installation standards according to SNiP

  • Gas boilers can be installed on fireproof walls at a distance of at least 2 cm from it.
  • If the wall is fire-resistant or combustible (wooden, frame, etc.), it must be protected with fireproof material. This can be a three-millimeter sheet of asbestos, on top of which a sheet of metal is fixed. Plastering with a layer of at least 3 cm is also considered as protection. In this case, the boiler must be hung at a distance of 3 cm. The dimensions of the fireproof material must exceed the dimensions of the boiler by 10 cm from the sides and bottom, and from the top must be 70 cm larger.

Questions may arise regarding asbestos sheet: today it is recognized as a material hazardous to health. You can replace it with a layer of cardboard from mineral wool. And also keep in mind that a fireproof base is also considered ceramic tile, even if it is laid on wooden walls: a layer of glue and ceramics provide just the required fire resistance.

The installation of a gas boiler relative to the side walls is also regulated. If the wall is non-flammable, the distance cannot be less than 10 cm. For flammable and non-combustible walls, this distance is 25 cm (without additional protection).

If a floor-standing gas boiler is installed, the base must be non-flammable. A non-flammable stand is made on the wooden floor. It must provide a fire resistance rating of 0.75 hours (45 minutes). These are either bricks laid on spoons (1/4 of a brick), or thick ceramic floor tiles, which is placed on top of an asbestos sheet fixed to metal sheet. The dimensions of the non-combustible base are 10 cm larger than the dimensions of the installed boiler.

The Italian company Ariston produces high-quality and durable equipment for hot water supply and heating. Gas boilers pleasantly combine efficiency with comfort and environmental friendliness.

General characteristics of Ariston gas boilers

Price segments of boilers and their quality characteristics

Ariston gas boilers in terms of cost can be classified as:

  • middle price segment CLAS EVO;
  • premium price segment GENUS EVO.

The average cost of models can be presented as:

  • from 29,000 rub. — CLAS EVO SYSTEM;
  • from 38,560 rub. — CLAS EVO;
  • from 41,160 rub. — GENUS EVO;
  • from 52,000 rub. — CLAS PREMIUM EVO SYSTEM;
  • from 58,000 rub. — GENUS PREMIUM EVO SYSTEM;
  • from 60,800 rub. — CLAS PREMIUM EVO;
  • from 65,200 rub. — GENUS PREMIUM EVO.

CLAS EVO boilers are produced as single-circuit and double-circuit. Equipped with an LCD display.

GENUS EVO boilers are equipped with a backlit matrix display. Thanks to additional personalization of the display, it is possible to configure the necessary information about the boiler parameters.

Uniting functions of boilers

Many characteristics of Ariston gas boilers are inherent in the equipment of any price segment. The menu of boilers of any price level is presented in Russian.

The presence of the AUTO function provides automatic setup power according to temperature changes inside and outside. All Ariston boilers have noise and heat insulation.

The company provides a 2-year warranty on traditional boilers and 3 years on condensing boilers. Any Ariston boiler is easy to install, operate and service. The many functions of boilers make them safe, for example:

  • pumping air from the heating circuit;
  • semi-automatic recharge;
  • protection against scale and freezing;
  • blocking circulation pump.

Available remote control work. In the event of a problem, the diagnostic system reports what happened. You can send a command to restart the boiler.

Features of condensing boilers

Simple wall models Ariston gas boilers cost 16,000 - 32,000 rubles. The cost of condensing boilers ranges from 40,000 to 45,000 rubles.

This price is explained by their high environmental friendliness, significant efficiency, and profitable operation. Their work is different high efficiency and low maintenance costs.

Condensing boilers are equipped with a modulating pump and fan, depending on the load level. As a result, energy is saved and noise is reduced.

Specifics of dual-circuit Ariston models

The presence of a dual-circuit mechanism means combining the functions of heating and supply hot water. The Ariston group of double-circuit gas boilers usually includes three series:

  • Genus,
  • Egis,
  • Clas.

Genus

The most functional and visually attractive are boilers Ariston Genus. They are equipped with primary and secondary heat exchangers with high performance.

The fan has smooth speed control. The boilers are equipped modern system controls with large LCD display.

Egis

Egis boilers are attractive in design and compactness. They differ intelligent system control and high efficiency. The AristonEgis boiler is equipped with two heat exchangers, a unique hydraulic group and a digital display.

It can operate under conditions of reduced gas pressure, low pressure and water consumption. Safe work provides many functions, including self-diagnosis. There are filters for mechanical water purification.

Heats an area of ​​260 m2. Weighs 30 kg. Price – 23,000-28,000 rubles.

Clas

The Ariston Clas gas boiler has gained fame as the most practical and economical of all Ariston boilers. It has two securely separated heat exchangers. The combustion chamber is turbocharged and closed.

The boiler is equipped with a pump increased power, expansion tank, digital display.

Heats an area of ​​230 m2. Weighs 30 kg. Price – from 26,000 rubles.

Gas boilers with thermal power 24 kW

Ariston gas boilers are available with different thermal outputs, starting from 24 kW (most optimal choice). Here are some models with this power:

1. The wall-mounted gas boiler Ariston BS II 24 CF has compact dimensions, light weight, two separate heat exchangers, original hydraulic group. Its individual advantages:

  • adaptability to low blood pressure gas and water;
  • normal operation at low temperature outside (up to minus 52 degrees); protection against scale and freezing;
  • self-diagnosis;
  • durability of the burner with protection against frequent switching on;
  • filters for mechanical water purification, etc.

Cost 24,100 rubles.

2. Ariston Class System gas wall boilers are different:

  • adaptability to Russian gas conditions;
  • open combustion chamber and natural exhaust;
  • temperature control;
  • the Comfort Plus function, which provides hot water desired temperature in 5 seconds, automatic shutdown after an hour and turning on at the first water intake;
  • continuously adjustable fan;
  • high power pump;
  • automatic diagnostics with display on a digital display;
  • possibility of connecting a programmable clock.

Cost 27,300 rubles.

3. Ariston Egis Plus wall-mounted gas boilers with traditional technology heating, auto diagnostics, built-in circulation pump, expansion tank capacity 8 liters.

Cost 22500 - 27600 rubles.

What do buyers say?

A wide variety of models of Ariston gas boilers opens up a wide field of choice for consumers. Customer reviews are also mixed.

Andrey, 32 years old. I put it to my parents a private house double-circuit wall-mounted boiler Ariston BS II 24 FF. The model is compact and, most importantly, economical. They began to pay almost 700 rubles less for heating. per month.

Vladimir, 28 years old. About wall gas boiler Ariston Egis Plus 24 FF. I installed it in my dacha instead of a water heater. Spent 27,000 rubles. I don’t mind this money, because everything suits me. The house is big, and so is the boiler. The heat lasts for a long time and heats up quickly in the morning.

Anatoly, 34 years old. I have been using the ARISTON CLAS 24 FF boiler for three years. Everything was wonderful. Suddenly the circulation pump recently failed. I can't find a new one. They say to order for a decent amount. I don't know what to do yet.

Ivan, 36 years old. On the advice of friends, I bought and installed an Ariston boiler with a closed firebox for a house of 170 square meters. m. First heating season went fine. In winter, the house became warmer than before. Many friends bought the same one and do not complain.

Dmitry, 38 years old. We “forked out” for the Ariston Genus 24 CF. I have been using the boiler for three years. During this time, not a single malfunction. I am completely satisfied with the stability and efficiency; I’m generally silent about the level of comfort. True, sometimes after a long swim the radiator cools down a little, but then the temperature is restored.

Ariston gas boilers comply with European environmental standards due to reduced emissions into the atmosphere harmful substances and environmentally friendly packaging without foam.

The purchase of this equipment serves as an economical and reliable solution for the conditions of a city apartment or country house.

The Italian company Ariston is a leader among manufacturers heating equipment. The variety of manufactured equipment is enormous, so make right choice, customer reviews, as well as our review, can help you decide which Ariston gas boiler to buy.

Heating boilers differ mainly in power and functionality. The main difference from other gas boilers is that Ariston gas boilers specifications are excellent, and the price is affordable for the most economical owners.

Ariston double-circuit boilers have gained the most popularity. It was loved by customers for its excellent appearance(there is a casing that covers all connection points), compact size, ease of operation, ease of maintenance. Plus, the Ariston gas boiler is quite silent and economical. Many functions are implemented for the safe use of boilers. Cleaning filters are provided.

Types and features of the design of Ariston double-circuit boilers

If we talk about installation, Ariston double-circuit gas boilers are available in floor-mounted and wall-mounted types. Floor-standing boilers are placed on a flat, stable base. Have steel or cast iron heat exchanger, so they are quite heavy and bulky. Very durable and can last quite a long time.

A more compact and lighter gas boiler wall-mounted Ariston, heat exchanger made of copper or stainless steel. The quality of operation of such boilers directly depends on the pressure of energy carriers (gas and water) in the pipelines. Gas boiler is functioning dual-circuit Ariston as a home heater and as a water heater. One circuit supplies heat to the radiators in the form of hot water, and the second circuit heats domestic water. When a hot water tap opens, the valve automatically closes and the boiler begins to work to heat the newly incoming cold water.

Ariston gas boilers come with an open or closed combustion chamber. Open type chambers imply an influx of air from the home where the boiler is located, combustion products are removed through ventilation. Boiler with combustion chamber closed type requires a forced draft device, that is, air is taken from outside the room, and combustion products are also released. There are built-in fans for this. Expansion tank 8 liters. The power of Ariston gas boilers can be either 24 kW or 28 kW, which is enough to heat an area of ​​500 sq.m.

There is protection for blocking the pump, against scale and freezing. The technique has a system self-diagnosis, All possible mistakes and failures are displayed on the LCD display. There are several modes that the Ariston double-circuit gas boiler is equipped with, the price of which does not depend on what mode is present in the boiler.

The following modes exist:


Just like Ariston wall-mounted gas boilers, Ariston floor-standing boilers also have different kinds controls: climamanager, t-control.

Popular double-circuit gas boilers Ariston

EGIS PLUS is a 24 kW gas double-circuit wall-mounted boiler with the Info function. Compact, lightweight, has two separate heat exchangers: copper and stainless steel. Hydraulic system made of composite durable material, this extends the service life. Each circuit is equipped with a filter. They can work in the most severe frost. The combustion chamber is found both open and closed. Economical. If you read user reviews about Ariston gas boilers, they are all unanimous: “Simple and clear system management, reliable protection from pressure surges."

These gas boilers are capable of operating at low temperatures gas pressure(up to 5 mbar), neither water flow nor low pressure in the main line has any effect on the functionality of the boiler. Changes in voltage in the electrical network are also not a hindrance. The heating power can be reduced, but the water heating power does not change. There are options: start delay, continuous electronic modulation of the flame in the burner, protection against freezing, against the accumulation of scale on heating devices, prevention of blocking pumping system and three-way valves.

The Ariston Egis Plus 24 FF gas boiler is equipped with independent diagnostics.

Three-way valve with motor drive. The boiler has two NTC sensors, two filters for mechanical cleaning, and an 8-liter expansion tank. If desired, you can connect a room thermostat and a T-Control digital thermostat-programmer. You can read how to choose a gas boiler for your apartment.


GENUS EVO is a wall-mounted boiler of the Comfort subseries. Very economical. Can save up to 35 percent of energy resources. Has two heat exchangers. One works like a stove - for heating the home, the other for hot water supply. Externally beautiful and easy to operate. Three temperature sensors, electric water pressure sensor. The circuits are equipped with filters. Taking into account all the advantages, the Ariston double-circuit gas boiler price is not high. But excellent efficiency.

Quiet and lightweight. Combustion chambers are found both open and closed. Maximum power 35 kW. Thanks to sensors, it “feels” the weather and adjusts the boiler itself, focusing on climatic conditions outside the window. You can set the temperature support level for a specific day of the week. For example, if you leave home every weekend, the boiler will not heat up on those days. full power. To buy a double-circuit wall-mounted gas boiler Ariston, you don’t have to go far. This line of boilers is known in almost every city.


CLAS B 24 CF – gas convection wall-mounted boiler.
It has an open combustion chamber, electric ignition. Heat exchangers are made of copper. One of the advantages is the presence of a built-in circulation pump, a 40-liter boiler, and a built-in 8-liter expansion tank. Equally capable of functioning on natural and liquefied gas. Equipped with a “Comfort” function. There is a power indicator, thermometer, pressure gauge, auto ignition, flame modulation.

BS II - economy-class wall-mounted double-circuit boilers with a power of up to 24 kW, operation and management are simplified as much as possible, designed for heating apartments and providing hot water to residents apartment buildings. It is distinguished by uninterrupted boiler service when the pressure in the lines decreases. For this purpose, the option “continuous electronic modulation of the burner fire” is provided, a whole range of options providing safe use boiler

It must be said that any Ariston 24 wall-mounted gas boiler, reviews confirm this, is equipped with the following safety functions: semi-automatic replenishment, pumping air out of the system, blocking the operation of the circulation pump, protection against freezing and scale accumulation. Compared to other brands, the Ariston BS 24 FF gas boiler is inexpensive, heats up quickly and is very energy efficient; there will be an excellent bonus in the form of reduced payments for housing and communal services.

Easy to use, small-sized, simple settings do not require special skills.

Economical, with a closed combustion chamber, protection against scale accumulation, non-freezing. Each Ariston double-circuit gas boiler has self-diagnosis; during use, you need to monitor the readings on the liquid crystal screen; it displays all failures and errors in the operation of the boiler.

The Ariston double-circuit gas heating boiler has two types of condensation model:


Pros and cons of gas double-circuit boilers Ariston

Regardless of the fact that the Ariston company is better known as a manufacturer of water heating devices, its gas boilers have become very widespread and extremely popular.

Ariston products have the following advantages:


The disadvantages that unite gas boilers from all manufacturers of heating equipment are mainly related to the quality of energy carriers:

  • all heating devices cannot tolerate bad, hard water;
  • gas of poor quality, reduces service life;
  • Without electricity, ignition is impossible.

If one of these energy carriers constantly enters the Ariston double-circuit gas boiler, malfunctions will sooner or later arise. More often than not, the pump or reservoir breaks down for this reason. Problems can arise due to poor air supply to the combustion chamber or incorrectly set temperature. is in high demand, so it is important to choose the right equipment.

In conclusion I would like to note great service, which the Ariston Company guarantees, there is no shortage of spare parts and components. If an Ariston gas boiler is installed in the house, the operating instructions clearly prohibit allowing children or persons who have not received safety training to operate it. It must be remembered that when turning off the gas boiler for a long period, you need to check that all taps on both circuits, especially gas tap were screwed in, and it is also necessary to disconnect the boiler from the power supply.

The quality of work does not depend on voltage changes in electrical networks, but if you still decide to buy an Ariston gas boiler, it is better to immediately purchase a voltage stabilizer. One-time voltage drops may not affect the operation of the boiler, but if the voltage in the electrical network fluctuates greatly and frequently, this can kill the boiler. The stabilizer can also burn out, but it is better to purchase another stabilizer than another boiler. When purchasing any Ariston double-circuit gas boiler, the operating instructions must be carefully studied. Following the recommendations will extend the life of the boiler for many years.