Error codes for air conditioners allow the service engineer to quickly find and efficiently fix faults.

Air conditioner diagnostics

This is the first thing to do before servicing or repairing it. Diagnostics of the air conditioner allows you to identify breakdowns and malfunctions in the system. Whether it is a lack of refrigerant that needs to be replenished, errors in the operation of the air conditioner, or malfunctions of the main components.

Timely and competent diagnostics of malfunctions will allow the service engineer to quickly and efficiently eliminate malfunctions. So, to return a healthy microclimate to the client's home or office.

All modern air conditioners have a developed self-diagnosis system. As a result of analyzing the state of the equipment, the system identifies the cause of the malfunction and displays the error code on the display (of the remote control, board or mode indicator). Below are the error codes for air conditioners (alarm code) various brands. Using this information, you can independently read the error code and repair the air conditioner. This will significantly save the time of equipment diagnostics and avoid inaccuracies in determining the nature and location of the breakdown.

Air conditioner error codes

We have selected for you information about error codes for air conditioners and split systems of different brands.

If you need an authorized service center for air conditioner repair - it's for us! EUROBUSINESS is your reliable partner!

Error codes for Beko BKN, AKN air conditioners

⊕ - blinking, 2 - on, 3 - off. If there are these errors, the operation of the air conditioner will be automatically terminated.

Error codes for Beko AKH, AKP, AS, BKH, BKP, BS air conditioners

Error codes for Beko inverter air conditioners BKC 090 INV, BKC 120 INV, BKL090 INV, BKL120 INV

If the BEKO air conditioner does not work, this is for us!

Error codes for Carrier air conditioners

If a malfunction is detected, the green indicator (P) and the orange indicator (R) flash at a frequency of 0.1 seconds, indicating a fault code. It should be noted that the orange indicator (R) corresponds to the tens in the number - the fault code. The green indicator (P) corresponds to the units in the number - the fault code.
There are 2 seconds between blinking orange and green indicators. The sequence is repeated at intervals of 4 seconds.

For example, fault code 13. Orange LED flashes once, both LEDs are off for 2 seconds, green LED flashes three times at 0.5 second intervals, both LEDs are off for 4 seconds.
The sequence is repeated until the fault is corrected. If the fault code is less than 10, then the orange indicator does not blink.

The code Description
2 Room temperature sensor malfunction
3 Malfunction of the temperature sensor of the internal heat exchanger Tc
6 Malfunction of the reversing valve of the outdoor unit
8 Malfunction of the fan motor in the indoor unit
9 Power is not supplied to the indoor unit
11 Malfunctioning drain pump or other drainage problems
12 Software bug indoor unit(wrong addressing)
13 Configuration error
14 Signal Loss central system management
15 Malfunction of the indoor heat exchanger temperature sensor Tcj
18 Malfunction of the outdoor unit control unit (G-Tr short circuit protection)
20 Error in block position recognition circuit
21 Malfunction of the current sensor in the outdoor unit
22 Malfunction of the outdoor heat exchanger temperature sensor
23 Discharge temperature sensor malfunction
24 Outdoor unit fan failure
26 Other outdoor unit malfunction
27 Outdoor unit compressor blocked
27 Invalid discharge temperature
29 Outdoor unit compressor failure
31 Increased pressure in the circuit of the outdoor unit

If the CARRIER air conditioner does not work, this is for us!

Error codes for Chigo air conditioners

If the CHIGO air conditioner does not work, this is for us!

Error codes for Daewoo air conditioners

Error code Cause of malfunction
F6 PG motor faults
F7 Indoor TEMP sensor faults
F8 Indoor coil pipe TEMP sensor faults
F9 Outdoor coil pipe TEMP sensor faults

If the Daewoo air conditioner does not work, this is for us!

Error codes for Fujitsu General air conditioners

Fujitsu General Ltd. introduced to the market New Product for diagnostics of split systems and multi-split systems GENERAL. The tool is a set of adapters connecting outdoor unit with a computer, and a PC program. With their help, a specialist conducting equipment diagnostics can see in real time the parameters of the compressor, fan motor, EEV, sensor readings, as well as an error log. In the process of testing, it is possible to record a work log with the issuance of a report.

The adapter is suitable for working with multi-split systems, as well as with most inverter split systems(wall, ceiling, channel, cassette).

Modern Fujitsu General air conditioners have a very advanced self-diagnosis system, according to the results of which the control system, when a particular malfunction is detected, blocks the operation of the entire device and at the same time reports the cause of the malfunction.

The Fujitsu General air conditioner control system reports any malfunctions by flashing an LED on the panel of the indoor (in some cases outdoor) unit. When a particular malfunction of the air conditioner is detected, the LEDs light up or flash in a certain sequence, which corresponds to the detected error. If the air conditioner control system has detected more than one error, then the malfunction with the highest priority is displayed first, and then all the others.

Error codes for Fujitsu General air conditioners are shown in the table.
Cause of malfunction Error display
OPERATION (red) TIMER (green) SWING (orange)
Indoor unit board failure O O -
Room temperature sensor wire open (indoor unit) 2 X O -
Short circuit in the room temperature sensor circuit (indoor unit) 2 X O O
Indoor unit piping sensor wire open 3 X O -
Short circuit in the indoor unit piping sensor circuit 3 X O O
Faulty indoor unit fan 6 X O -

For some models (see list *), depending on the error, the OPERATION, TIMER, SWING indicators work according to the following principle: O- fast blinking; X- slow blinking; - OFF

* Внутренний блок: ASG18FBAJ, ASG18FBBJ, ASG18UBAJ, ASG18UBBJ, ASG24FBBJ, ASG30FBBJ, ASG18FBBX, ASG18UBBN, ASG24FBBN, ASG24UBBN, AWG18FBAJ, AWG18FBBJ, AWG18UBAJ, AWG18UBBJ, AWG24FBBJ, AWG24UBBJ, AWG30FBBJ, AWG30UBBJ, AWG14UBBJ, ABG14FBBJ, ABG14FBBJ, ABG18FBBJ, ABG18FBBJ, ABG181BBJ, ABG181BBJ, ABG24FBBJ, ABG24FBBJ, ABG241BBJ, ABG241BBJ, AWG24FBAJ, AWG24UBAJ.
* Внешний блок: AOG18FNAK, AOG18FNBK, AOG18UNAKL, AOG18UNBKL, AOG24FNBK, AOG24UXBKL, AOG30UNBDL, AOG18FNBX, AOG18UXBXL, AOG24FXBX, AOG24UXBXL, AOG18FNAK, AOG18FXBK, AOG18UNAKL, AOG18UXBKL, AOG24FNBK, AOG24UXBKL, AOG30FNBDL, AOG30UNBDL, AOG14USBJ, AOG14FNBK, AOG14FXBX, AOG18FNBK, AOG18FXBX, AOG18UXBKL, AOG18UNBNL, AOG24FNBK, AOG24FXBX, AOG241XBKL, AOG24UXBXL, AOG24FXAD, AOG24UXADL

If the Fujitsu General air conditioner does not work, this is for us!

Error codes for Haier air conditioners

Repair of air conditioners HAIER (HAYER) is carried out on the basis of an analysis of the operating parameters of devices and fault codes.

If there are no errors or malfunctions, but the unit does not start, the start conditions may not be as required. In this case, the following standby codes will be displayed on the display of the head unit:

Error codes and malfunctions of indoor units of HAIER air conditioners

Remote display indication Number of flashes LED5 / Timer Description of the fault
01 1 Tai Ambient Temperature Sensor Malfunction
02 2 Malfunction of the temperature sensor of the heat exchanger TC1
03 3 Malfunction of the temperature sensor of the heat exchanger TC2
04 4 Dual Energy Source Temperature Sensor Malfunction
05 5 Indoor unit board EEPROM error
06 6 No communication between indoor and outdoor units
07 7 No communication between indoor unit and wired controller
08 8 Condensate drain error
09 9 Duplicate indoor unit address
0A 10 Duplicate indoor unit central address
Fault codes for outdoor unit 20 Corresponding malfunction of the outdoor unit

Error codes and malfunctions of the inverter outdoor unit

Remote display indication Error code Description of the fault
20-0 Frost protection sensor t error TE1 AD value is less than 11 (loop open) or greater than 1012 (loop closed) for more than 60 seconds. in cooling mode, if the sensor is faulty, the unit does not use its readings, except for the defrost function or for 3 minutes. after its completion; no alarm
20-1 Frost protection t sensor error TE2
21 Outside air temperature sensor error Ta
22 Suction temperature sensor error Ts AD value is less than 11 (loop open) or greater than 1012 (loop closed) for more than 60 seconds. in defrost mode or for 3 min. after its completion; there is no alarm.
23 Discharge temperature sensor error Td After 5 minutes of compressor operation, the AD value is less than 11 (open circuit) or greater than 1012 (closed circuit) for more than 60 seconds. during start-up, in defrost mode or for 3 min. after its completion; no alarm
24 Toil oil temperature sensor error AD value is less than 11 (loop open) or greater than 1012 (loop closed) for more than 60 seconds, (loop closed) for 60 seconds; if within 5 minutes Ta 2 -10°C or ET< -10®С, сигнала тревоги нет.

The tables show only some of the HAIER air conditioner trouble codes. We remind you that HAIER air conditioners are technically sophisticated equipment. Error codes are provided for qualified and certified technicians. That is, for those who are professionally engaged in the repair of HAIER air conditioners, and not for ordinary users. Trust the repair of HAIER air conditioners to professionals.

If the Haier air conditioner does not work, this is for us!

Hisense Air Conditioner Error Codes

If a malfunction occurs, press the Sleep button on the remote control 4 times - the error code will light up on the 7-segment display (see table below). If there are several errors, then press the Sleep button 4 times again - the LED indicator will light up with the following error code.

The updated remote control, which has 4 modes of operation of the "Sleep" button, allows you to set 4 different combinations. When using it to check error codes, you must press the "Sleep" button 10 times. After that, error codes will start to be displayed.

The code Cause of malfunction
1 Outdoor heat exchanger temperature sensor error
2 Compressor discharge temperature sensor error
5 Integral Power Module (IPM) protection trip
6 Operation of the overvoltage or undervoltage protection device in the AC mains
7 Communication error between indoor and outdoor units
8 Overload protection device
10 Communication error between two microcircuits (control and drive) in a printed
11 Outdoor unit EEPROM memory error
12 Tripping of the protection device at low outside temperatures
13 Tripping of the protection device as a result elevated temperature in
14 Outside air temperature sensor error
15 Compressor thermal protection trip due to overheating
16 Operation of the heat exchanger frost protection or overload protection device when the indoor unit is operating in heating mode
17 Reactive Power Compensation (PFC)
18 DC compressor start error
19 Compressor drive error

Error codes for IGC air conditioners

IMS MINI (IMS-EM080NH, IMS-EM100NH, IMS-EM120NH, IMS-EM140NH, IMS-EM160NH)
The code Malfunction
CH Liquid pipe thermistor failure
CJ Temperature sensor malfunction
E6 Suction tube temperature protection frequency limits "TS"
E7 Protection Frequency Limits average temperature external capacitor
E8 Protective stop of external capacitor
E9 Compressor Frequency Limits for Extreme High Temperature
F4 Low pressure sensor problems
F5 Low Pressure Transmitter Protection Limits for Ultra High or Ultra Low Frequency
F6 Low pressure safety shutdown for ultra-high or ultra-low frequency
H8 Constant frequency compressor overcurrent protection 1
H9 Constant frequency compressor overcurrent protection 2
ON Input voltage overvoltage and undervoltage protection
NS Incorrect phase sequence of fixed frequency compressor 1
HH Wrong phase sequence frequency converter compressor
HJ Wrong phase sequence of fixed frequency compressor 2
J4 Communication error with control panel and fan motor
J5 Error setting the address or load settings of the outdoor unit
38 Radiator temperature protection frequency limits
39 Radiator shutdown
3A DC fan protection
DC fan surge protection
3H Power on error or asynchronous fan operation
3J DC fan surge protection

Error codes for Kentatsu air conditioners

Error codes Kentatsu KSVP-HF

E2 - room temperature sensor malfunction
EЗ - malfunction of the evaporator temperature sensor
E4 - malfunction of the temperature sensor of the outdoor unit
E6 - outdoor unit malfunction
E7 - EEPROM error
E8 - excess water level

Error codes Kentatsu KSKT-HF channel type

E0 - Faulty room temperature sensor
E1 - Faulty evaporator temperature sensor
E2 - Faulty outdoor unit temperature sensor
E3 - outdoor unit defective
E4 - faulty drain pump temperature sensor
E5 - EEPROM error
E6 - rising water level

Error codes Kentatsu KSFU models: KSFU/KSRU76HFDN3, KSFU/KSRU140HFDN3

P4 - thermal protection of the evaporator of the indoor unit
P5 - thermal protection of the capacitor of the external unit
P9 - protection of the defrost function or creation of a comfortable air flow
E1 - break or short circuit T1 temperature sensor circuits


E6 - outdoor unit protection

Error Codes Kentatsu KSGH/KSRH

Models: KSGH/KSRH21CFDN1 KSGH/KSRH26CFDN1, KSGH/KSRH35CFDN1 KSGH/KSRH53CFDN1, KSGH/KSRH21HFDN1 KSGH/KSRH26HFDN1, KSGH/KSRH35HFDN1
E1 - EEPROM error (non-volatile memory on the board)
E2 - zero crossing error
EЗ - abnormal fan speed
E4 - compressor current protection tripped 4 times
E5 - indoor air temperature sensor shorted / broken
E6 - evaporator temperature sensor shorted / broken

Kentatsu Error Codes floor type KSFU70XFAN1 /KSRU70HFAN1, KSFU120XFAN3 / KSRU120HFAN3

P4 - evaporator temperature protection
P5 - condenser temperature protection
P7 - Discharge temperature too high. Compressor protection enabled
P9 - too low outdoor temperature, when it rises, the protection will turn off automatically
P10 - outlet pressure protection
P11 - suction pressure protection
P12 - overcurrent protection
E1 - indoor air temperature sensor T1 shorted / broken
E2 - evaporator temperature sensor T2 shorted / open
E3 - T3 condenser temperature sensor short/open
E4 - outdoor temperature sensor closed T4 shorted / broken
E5 - communication between the indoor and outdoor units is broken
E6 - outdoor unit protection
E10 - compressor suction pressure error
E13 - compressor phase error
E14 - incorrect compressor phasing
HS - start defrost

If the Kentatsu air conditioner does not work, this is for us!

Error codes for LG air conditioners

The code Cause of malfunction
F01 Open / short circuit room room (air) temperature sensor of the indoor unit
F02 Open/short circuit of the pipe temperature sensor of the indoor unit
F03 Lack of communication between the control panel and the main control board for more than 2 minutes
F04 Open / short pipe temperature sensor of the outdoor unit
F05 Open / short circuit room air temperature sensor of the outdoor unit
CH01 Malfunction of one of the thermistors of the board (break or short circuit) of the indoor, wall-mounted unit of the split system - control of the temperature of the incoming air and the tube of the gas circuit of the air conditioner
CH02 Malfunction of one of the thermistors (break or short circuit) of the outdoor unit: inlet air temperature sensor or gas circuit pipe temperature sensor
CH03 The air conditioner works simultaneously for heating and cooling the air
CH04 Compressor overload protection system included
CH05 Communication error between the indoor and outdoor units of the split system
CH06 The current consumption of one or more actuators of the outdoor unit-relay was briefly above the norm
CH07 Current consumption of the entire outdoor unit long time was above normal
CH08 Fan motor failure
CH09 4-way valve malfunction
CH10 The thermistor for controlling the temperature of the compressor housing of the split system is faulty (open or short circuit)

LGMV is a mobile application developed by the manufacturer for remote monitoring of operating parameters of LG air conditioning systems. The app helps engineers evaluate Current state equipment. The analysis is based on a multi-year operation cycle. The program helps not only to quickly identify problems in the system, but also gives recommendations for resolving the issue.

The LGMV diagnostic system provides monitoring of system operating parameters, prevention and prevention of system malfunctions. All this certainly simplifies diagnostics and commissioning. LGMV consists of a wireless communication module and a free smartphone app. To use the LGMV mobile application, an exclusive Bluetooth module is required, the corresponding connector of which must be connected to the CN-LGMV port on the main board of the outdoor unit.

LGMV main features:

Visual display of key information about the operation of the air conditioner.
Graphic indication of pressure and other parameters.
Controls the operation mode of the indoor units when the unit is connected to the outdoor unit.
Saving data on the operation of the air conditioner as a file.
Operation report — the result of the testing operation is generated into an HTML document.
Error number indication and support for error search in the list from PDF document.

Mobile LGMV can be downloaded, for example, from Google Play as a product of LG Electronics, Inc. as a tool for Maintenance, troubleshooting for LG air conditioning systems. The LGMV mobile application uses a limited resource on a smartphone and processes data in real time. Data monitoring may be difficult or data may not be fully saved if the performance of the smartphone is poor.

It is recommended to use a high performance smartphone. If system resources are insufficient due to other Internet applications that are enabled, data monitoring may fail in addition to monitoring. The monitoring function and saving function may not work fully. And also Bluetooth communication connection can be disabled. In addition, the application may be disabled due to a lack of resources or an unexpected error.

The communication level may increase depending on the number of outdoor and indoor units. Bluetooth transmission distance may be shortened to the point of turning off data transmission depending on the weather or conditions. environment(electromagnetic waves or obstacle), etc. It is recommended to use the Bluetooth module for a short distance.

If the LG air conditioner does not work, this is for us!

Error codes for MDV air conditioners

Error indication on MDV indoor unit

If you need diagnostics of the MDV air conditioner - this is for us!

Error indication on external MDV unit
E0 eeprom error
E1 Error on the temperature sensors of the indoor unit 1
E2 Error on the temperature sensors of the indoor unit 2
E3 Error on the temperature sensors of the indoor unit 3
E4 Outdoor unit temperature sensor error
E5 High or low voltage protection
E6 Error on the temperature sensors of the indoor unit 4
E7 No communication between control and inverter boards
P0 Compressor overheating protection
P1 Protection by high pressure- only for M4OCi
P2 Protection by low pressure- only for M4OCi
P3 Compressor overcurrent protection
P4 Inverter module protection tripped
P5 Low outdoor temperature protection -7°C
P6 High condensing temperature protection

If the MDV air conditioner does not work, this is for us!

Mitsubishi Electric Air Conditioner Error Codes

If the Mitsubishi Electric air conditioner does not work, this is for us!

Mitsubishi Heavy Air Conditioner Error Codes

If the air conditioner does not work Mitsubishi Heavy- it's for us!

Error codes for Wisnow air conditioners

If the Wisnow air conditioner does not work, this is for us!

Error codes for Polaris air conditioners

If the Polaris air conditioner does not work, this is for us!

Sanyo Air Conditioner Error Codes

Description of the malfunctions that are indicated on the board of the SANYO W-ECO MULTI SYSTEM outdoor unit. Valid for SPW-CR1503GDYH8, SPW-CR1903GDYH8, SPW-CR703GDCH8, SPW-CR903GDCH8, SPW-C1503GDYH8, SPW-C1903GDYH8, SPW-C703GDCH8, SPW-C903GDCH8.

If the Sanyo air conditioner does not work, this is for us!

Sharp Air Conditioner Error Codes

For example, fault indication in SHARP air conditioners models AY-A184E / AE-A184E, AY-A244E / AE-A244E.

If the Sharp air conditioner does not work, this is for us!

Error codes for Toshiba air conditioners

The code Malfunction
00-0s indoor air temperature sensor error or indoor unit board error
00-0d error of the temperature sensor of the radiator or control board
00-11 defective board or fan motor
00-12 need to replace control board
01-04 fuses on the board burned out, incorrect interconnection, board burned out
01-05 inverter board error
02-14 inverter overcurrent
02-16 short circuit between compressor windings
02-17 current sensor error
02-18 error of temperature sensors, PC board
02-19 error temperature sensor TD, PC boards
02-1a outdoor unit fan error - overcurrent, blocked, burnt motor or board
02-1b condenser temperature sensor defective or board
02-1c compressor did not start within 20 seconds
03-07 lack of refrigerant, inverter board error
03-1d defective compressor
03-1e suction tube sensor error TD, not enough refrigerant
03-1f compressor does not work due to supply voltage, overload of the refrigeration circuit
03-08 four-way valve malfunction

If the Toshiba air conditioner does not work, this is for us!

The work performed during the diagnostics corresponds to the work performed during. The only difference is that during the diagnostics, all the main parameters of the equipment operation are checked and recorded, and when after-sales service identified deviations from the norm are eliminated.

The list of works in the diagnosis of air conditioning

During the diagnosis of the air conditioner, firstly, visual inspection for the absence mechanical damage. Not only hull, but also hydraulic and electrical parts of the equipment are inspected. In addition, the reliability of the fasteners of the external and internal units is checked. As well as the quality of the clamps of all contact connections electrical equipment. Before turning on the equipment, you need to check the status air filters. They must be not only clean, but also without damage. After inspection, as a rule, switching to the "cooling" mode is performed. Use the remote control to test the system.

During the functional test, the indication of the air conditioner modes is evaluated, as well as the operation of the mechanically driven exit blinds. One of the indirect indicators of the efficiency of the system is the control of the temperature of dry air at the inlet and outlet of the evaporator. With the help of pressure gauges, the average suction / discharge pressure is measured (with free access to the outdoor unit). Of course, it is mandatory to check the tightness of the connection between the indoor and outdoor units. In addition, you need to make sure that there are no leaks in drainage system conditioner.

If something went wrong

The specialist can also judge the nature of the malfunction by the “behavior” of the air conditioner. For example, if the air conditioner turns on and immediately turns off, after which an error message is displayed - most likely, the matter is in the sensors (malfunction of the air temperature sensors or the evaporator).

If the air conditioner turns on, runs for 15-20 seconds, and then turns off, the indoor unit fan motor is most likely defective (rotation speed is lower than the set rpm).

If the air conditioner does not turn on at all and at the same time all the LEDs flash (or do not light up), most likely, the control circuit board has failed.

Simultaneous flashing of all indicator lamps of the air conditioner, as a rule, means only a failure of the program settings of the control board. Most likely, this is due to the non-compliance with the GOSTs of the network parameters, for example, due to a power surge in the network. It is not difficult to eliminate this malfunction - it is enough just to reprogram the main control board. Since information about codes is provided only to authorized service centers, in this case you need to contact our experts.

Before…

If your air conditioner does not work, first of all make sure that the air conditioner is securely connected to the outlet. Check the circuit breaker or fuse on the supply line, if necessary restart the circuit breaker or replace the fuse. Read the user manual again and make sure all modes are set correctly.

Doing it yourself will save you money. Because in many cases the engineer you called, after doing what you can easily do yourself, will charge you for the false call.

If these steps do not help, then contact the sales organization that sold you the air conditioner. Or contact an authorized service center of the air conditioner manufacturer. Without a doubt, this is the best, fastest and most reliable way to get your air conditioner back up and running. The sales organization that sold the air conditioner should give you information on how to contact them. This information is available not only in the warranty card, but also on the manufacturer's website in the appropriate regional section.

Air conditioner test mode

To facilitate diagnostics, modern air conditioners have a so-called test mode. Compared to the operating mode, the air conditioner turns on in cooling mode and does not respond to sensor readings and air temperature. That is, in the test mode, the air conditioner will function as long as it is necessary for the service engineer to study the operation of the system units. After turning off the test mode, the air conditioner will return to normal mode work.

Samsung air conditioners also have a test mode. To enter the test mode, press the on / off button on the indoor unit and hold it for five seconds. At the same time, the temperature indicator displays the installed option. software settings with a second interval, for example, 0b0000-1730F8: 0b00001730F80b (only for models with a temperature indicator).

When testing the operation of the air conditioner, the cooling mode is switched on with the following restrictions:
- The compressor is forced to run in cooling mode without turning on/off according to the set internal temperature, without defrosting mode;
- Vane, guide air flow up/down - turn up/down mode;
- The indoor fan rotates at high speed.

AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Vitek, digital display for air conditioner series fault:

  • Display mode = E4
  • Priority level display = 1 Non-mitsubishi52_63_71he-s power supply failure = Plastic temp sensor is abnormal.
  • Display mode = E1 Priority level display = 2
  • Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3
  • Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = E2 Priority level display =
    4

2. H series, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Renova (except KFR-25G/H) h3 HA HB series fault display:

  1. Power supply failure = PG feedback engine abnormal
  2. Priority level display = 1 Power supply failure = Plastic temp sensor abnormal Display mode = Timer LED blinks 1 time every 8 seconds
  3. Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds
  4. Priority level display = 3 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 1 time every 1 second
  5. Priority level display = 4

3. Series H (Y) air conditioner model remote display, removable panel AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu:

  1. Power supply failure = Motor feedback PG abnormal Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1
  2. Power supply failure = Plastic temp sensor. abnormal Display mode = Timer LED flashes 1 time every 8 seconds Priority level display = 2
  3. Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3
  4. Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = Timer LED flashes 1 time every 1 second Priority level display = 4

4. E. E. E. EU EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display air conditioner series AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Troubleshooting:

AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu power supply failure = Motor feedback PG abnormal Display mode = E4 Priority level display = 1

E1 or EL - as a common nutrition mistake.

Power supply failure or, in Russian, mains voltage< 210 В (сработала защита – токовая нагрузка) = Датчик темп ненормально Режим отображения = E1 Отображение уровня приоритета = 2

E1 - pretty common mistake, just yesterday I encountered.

    The reasons for E1 are obvious - insufficient voltage in the network< 210 В. При пуске компрессора происходит дополнительная просадка напряжения, токовая нагрузка max.
    Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3

1

1

5. All other E series except EA EU E.M.E.U.Z. EAA EAD:

Power supply failure = PG motor feedback abnormal

Display mode = Timer LED blinks 4 times every 8 seconds

Priority level display = 1 Power supply failure = Plastic temp. abnormal Display mode = Timer LED blinks 1 time every 8 seconds

Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3

6. QA QB QD digital display of AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Vitek, Renova air conditioners - malfunctions, error codes:

  • Power supply failure = PG motor feedback abnormal Display mode = E4
  • Priority level display = 1 Power supply failure = Plastic temp sensor abnormal Display mode = E1
  • Priority level display = 2 Power supply failure = Copper temperature sensor abnormal
  • Display mode = E3 Priority level display = 3 Power supply failure = overcurrent oprotection
  • Display mode = E6 Priority level display = 4

1

1

7. QC QQ light display air conditioner series fault:

  • Power supply failure = PG motor feedback abnormal
  • Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1 Power supply failure = Plastic temp sensor abnormal
  • Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2 Power supply failure AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu = Copper temperature sensor abnormal
  • Display mode = Timer LED blinks 3 times every 8 seconds Priority level display = 3 Power supply failure = over current oprotection
  • Display mode = Timer LED blinks 6 times every 8 seconds Priority level display = 4

1

1

8. Display faults of 18000BTU ~ 24000BTU, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Renova series - wall mounted air conditioner series:

  • Numbers for digital tube displays:
  • Power supply failure = PG motor feedback abnormal
  • Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2
  • System errors = turns off Power supply failure = Plastic temp sensor abnormal Display mode =
  • Timer LED blinks 2 times every 8 seconds Priority level display = 3 System errors = turns off
  • Power supply failure = Copper temperature sensor abnormal Display mode = Timer LED blinks 8 times every 8 seconds Priority level display = 4
  • System errors = not turning off Digital tube displays: Power supply failure = PG motor feedback abnormal Display mode = E1
  • Priority level display = 2 System errors = turns off Power supply failure = Plastic temp sensor abnormal Display mode = E3
  • Priority level display = 3 System errors = turn off Power supply failure = Copper temperature sensor abnormal Display mode = E2 Priority level display = 4
  • System errors = does not turn off

Error codes are needed if your split system is broken, how to fix the problem, what you need to know, including the consumer, so that you are not cheated at the service center.

Split system error codes

Possible breakdowns of refrigeration equipment are determined by error codes, it is not necessary to be a specialist to determine the cause of the breakdown by codes

The main directions for troubleshooting are simple ... If the error code F-1, F-2, F-3, F-4, F-5, F-6, F-7, etc. is displayed, then the problem must be sought in temperature sensors and everything connected with them on the control board does not pass the signal, open or short circuit.

If the error code E-1, E-2, E-3, E-4, E-5, E-6 ... etc. is displayed. E-0, EL, while the air conditioner either starts and works for some time, or does not start at all, then we are looking for a solution to the problem with the operation of the split system in the power unit: the reasons are different ... from the complete failure of the start signal to the critical current characteristics to turn off the system .

As an example: the bearing of the fan of the indoor unit is pinched, the fan impeller rotates but at insufficient speed, the hall sensor or the torque sensor does not send a signal to the control board, the split system gives an error E 1 ... E-L after 1-5 minutes, the problem is found.

Malfunctions and malfunctions of Toshiba air conditioners, fixing errors in the operation of your favorite split system

  • Error codes 00, malfunctions related to the power of the air conditioner, critical malfunctions
  • Fault table and possible problems, repair methods and troubleshooting Toshiba air conditioners
  • We repair Toshiba, fault tables and error codes for professionals, errors from 14 to 22
  • toshiba_mul "ti system errors with two or more internal ... and much more, everything is on this page of the site.
Toshiba air conditioning systems are easy and simple to repair if you have a service manual, we give you the opportunity to become at least a little smarter for free.
Toshiba RAV series - air conditioner problems or error codes

Samsung Air Conditioner Remote Control

Air conditioner control panel Samsung, is not just a set of buttons that set certain predefined functions air conditioner, but it is also a programmer, tasks the firmware of the split system board itself.
    On the remote, with the help of certain successive button presses, you can remove both cockroaches and correct Samsung errors.
P / U fig.1.
But, if, nevertheless, your Samsung has a nuisance, - Samsung broken down, do not rush to call the air conditioner repair service center, try to flash the air conditioner board and return the settings of the Samsung split system to the factory settings.
Samsung - air conditioner trouble codes | Samsung board firmware

Sources: error codes for popular air conditioners Error Code Air Conditioner...

welcome to the page with direct links to sources of information about error codes, malfunctions of industrial split systems and VRV air conditioning systems, the source sites also provide information about chiller-fan coil systems, fault codes and main breakdowns climatic equipment. Air Conditioner Hardwired Remote Controller System Error Codes.
Mitsubishi, Fujitsu, Acson, Dantex, Mitsubishi-Heavy, Chofu, Akira, General Electric, General Climate , Gree, General-Fujitsu, Sanyo, Daikin, Toshiba, Electrolux, Kentatsu, Neoclima, Midea, McQuay, Panasonic, AUX, West, Whirlpool, Yamaha, Euronord, Pioneer, Mitsubishi-Electric, Hyundai, Dantex classik Toyo, Chigo, DAX, RODA, Renova, Quattroclima, Lessar, Supra, Saturn, Ferroli, Hualing, Tadiran, Daewoo, Airwell, York...

If you did not find your air conditioner in this long list, don't worry, click on the source link... everything is there.

error code air conditioning | Error codes, originals pdf file

Damaged thermistor

1) Check the transmission wire. 2) Check with another remote controller. If "EO" is still indicated, replace the internal controller board. If another checkered code appears. replace the original remote controller. Error codes. Mitsubishi Electric

P1 Abnormality of room temperature thermistor (RT1) 1) Bad contact of thermistor 2) Damaged thermistor 1) Check the thermistor. 2) Measure the resistance of the thermistor. Normal resistance should be as follows. 32°F-15k | 86°F ..... 4.3k 50°F...... 9.6k 104°F..... 3.0k 68°F...... 6.3k If resistance is ok, replace inner tip dispatchers. P2 Abnormality of internal coil thermistor (RT2) P3 Signal transmission error (The remote controller does not respond to the controller's internal signal.) 1) Bad contact of the transmission wire 2) Signal transmit/receive circuit is incorrect. 3) Wrong operation due to noise wave emitted by other appliances

1) Check the transmission wire. 2) Check with another remote controller. If "P3" is still indicated, replace the inner board. If another checker code appears, replace the original remote controller. 3) Short circuit between and from CN40 and attach CN40 to the following units. Second unit in dual control Second and third units in triple control Sub units in group control P4 Leak sensor abnormality 1) Poor transmission contact cables
Air conditioners Mitsubishi-Electric | Split system malfunctions, error codes

Break down much more often

Frequent breakdowns of air conditioners of the budget series are due to the fact that split systems are lower price category break much more often, since almost all components, parts, and mechanisms of coolers are minimized at a price.

Error codes for air conditioner groups - DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Renova - with interchangeable printed circuit boards of the same name.

Error codes for entire groups budget air conditioners, - DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Vitek, Daihatsu, Renova, - with interchangeable circuit boards of the same name. Firmware for the board of cooling devices of these brands by default.

E1 or EL - pay close attention to this malfunction in the operation of the air conditioner, it is usually not related to the quality of the cooler, this is an external system error associated with poor-quality voltage in the power supply network.

Error display code | AUX, DAX, JAX, Pioneer, Hansa, Saturn, Vitek, Rolsen, Yamatsu, Daihatsu

Breakdowns of Mitsubishi-Heavy split systems

Display readings on the Mitsubishi remote control.

EA error code Why doesn't Mitsubishi work? Incorrect installation of the Indoor / Outdoor, - unit. exceeds the number of internal inclusions, connecting block, break. Check temperature and pressure sensors...

Error code Eb Malfunction of the split system. Incorrect installation of the Indoor / Outdoor, - unit. (Incorrect installation, check correct connection) Check temperature and pressure sensors...

EU error code Malfunction. Time trigger, start delay. Check temperature and pressure sensors...

Error code E6 Malfunction. Internal / external, - control board malfunction (signal receiver does not work). Closed when checking

Error code E7 Malfunction of the Mitsubishi air conditioner. Internal / external, - incorrect signal formation (incorrect connection, break, short circuit). Closed when checking

Error code E8 Mitsubishi-Heavy air conditioner malfunction. Internal / external, - control board malfunction (signal receiver does not work).

Mitsubishi-Heavy, troubleshooting the cooling circuit.

Troubleshooting the cooling circuit.

Check temperature and pressure sensors...

Error code E9 Air conditioner malfunction. Internal / external, - incorrect signal formation (incorrect connection, break, short circuit). Check temperature and pressure sensors...

Mitsubishi-Heavy Cooling System Malfunctions, Service Manual

Search faults and breakdowns of split systems McQuay/Acson, it is necessary to start with the common causes of breakdowns and equipment failure. Common causes include electrical malfunctions and malfunctions of the refrigeration circuit.

Name of McQuay/Acson equipment, their analogues and modifications.
McQuay ... McQuay and Acson, - possible malfunctions and errors

Carrier air conditioner broken

If your Carrier air conditioner has broken down, then something extraordinary and beyond reason has really happened.

Carrier are so reliable and durable that it is extremely difficult to break this device even with a strong desire. But, anything happens ... meteorites fall ... Malfunctions of Carrier split systems

The main malfunction of LG air conditioners ...

As a rule, the main malfunction of LG air conditioners is insufficient voltage of the power supply network. Chubaisyats spoil LG air conditioners. How to fix a breakdown? How to identify a malfunction using blinking indicators. What do these blinks mean?

How many times this or that indicator lamp blinked, you can see based on the figure above. How to find an error using indicators - LEDs of the indoor unit of air conditioners.
How many times this or that indicator lamp blinked, you can see based on the figure above.
  • Error code = 21, as an example in the picture.
  • Perhaps you have a different error code, but the analogy is clear.
  • Error codes for both conventional split systems and multi air conditioners
  • LG with two or more indoor units, examples of error codes taken from the indoor unit of a multi split system, as an example:
LG, - tables of code errors for air conditioners | How to determine the malfunction ... LG error codes

Haier air conditioners also break like everyone else Appliances, fault codes and possible errors in the split systems of this brand, you can easily determine the fault table on the page of our website.

The operation algorithm of Haier Electric Corporation air conditioners is so simple that even a novice amateur repairman can figure it out.
If all repair work carried out sequentially, the result simply must be positive.

Haier Electric Corporation error codes

Incorrect maintenance of the Haier air conditioner is the main malfunction. Crooked hands are the reason that disables Haier split systems.
  • Crooked hands are the reason that disables Haier split systems.
  • Haier Electric Corp. Models of the HSU-HVA R2-4 series air conditioner error codes.
  • Model HSU-09/12HVA103/R2 (DB) or equivalents
  • Model HDU-24CA03 / M (R1) HDU-28CA03 / M (R1) HDU-36CA03 / M (R1) HDU-42CA03 / M (R1)
Haier, fault codes | Model HSU-09/12HVA103/R2 or equivalent

Panasonic air conditioner repair. Finding and fixing system bugs. Error codes and malfunctions of Panasonic air conditioners (Panasonic).

Panasonic how to solve an unexpected problem

To be fair, we note that Panasonic air conditioners also break.

Breakdowns and malfunctions in split systems under the well-known multi-national brand National Panasonic, as well as the main malfunctions of split systems are presented in our article on the repair of this type of coolers.

If your Panasonic blinked like Christmas tree and does not want to execute the commands given from the air conditioner control panel, then this article will help you figure out and fix an unexpected problem. Everything is being repaired! Even split systems National Panasonic. In fairness, we note that Panasonic air conditioners also break down.

Finding and fixing system bugs. Panasonic error codes.
  • Panasonic, how to find the error code, it is not difficult to determine the breakdown of the air conditioner, you need to carefully monitor the display and look at the Panasonic error map there is a picture.
In order to order a panasonic brand air conditioner repair from us, just call our operator and leave a request. … repair of Panasonic air conditioners. Name of service. Price, rub
Panasonic, air conditioner repair | Finding and fixing system errors

Gree, like an air conditioner, is functionally simple, so there are not many error codes. Downsides of simplicity Gree air conditioners, - these are weak varistors of the control board, insufficient smoothing of currents during voltage surges. A trifle, but it must be borne in mind when repairing air conditioners Gree and their analogues.

Self-diagnosis of Gree air conditioners

The internal self-diagnosis of Gree air conditioners is unified and almost identical in error positions to inexpensive air conditioners, such as Pioneer, General Climate, Lessar and others.
Everything is similar and almost everything is being repaired: you just need to have a little patience and confidence in the success of the repair company. Everything will be fine...
Gree: Error and Fault Codes | Easy Repair

Daikin error codes... Faults on these glorious Daikin Daichi air conditioners. Air Conditioner Troubleshooting Table Daikin. Full size Images. 2500*2000 link.

Error codes, click on the Daikin remote control buttons.

Which buttons to press and when? Schematic version. The split system error code will be displayed on the screen. It is very convenient for self-testing. And then there are times when a "master" of repair comes and ... let's wind up the price for repairing an air conditioner from the eyes of a client. And there the problem is a penny. As an example, wipe the thermal sensor of the indoor unit with a cloth, or simply clean the filter ...
Independent troubleshooting of Daikin air conditioners. Pre-repair diagnostics of the Daikin split system.
Daikin error codes | Daikin air conditioner problems

Fault codes Fujitsu, General-Fujitsu | Which buttons to press and when? Repair

We look in the book and see ... what we need. Fault Paradox Fujitsu, General-Fujitsu. Fault codes for split systems Fujitsu, General-Fujitsu. Fujitsu, General-Fujitsu, Fuji. Air conditioning trouble codes, system error control or System Controller Error Fujitsu. When EE: EE is displayed on the Fujitsu remote control, press the power saving button and the mode change button at the same time for more than 3 seconds. Error codes will be shown on the display. (1) stop the air conditioner. (2) Press the master control button and the fan control button at the same time for 2 seconds or more to start the test run (3) Press the start/stop button to stop the test run Error code = 01 Fault = Communication error (indoor unit with outdoor unit) Error code = 02 Fault = Room temperature sensor open, open circuit Error code = 03 Fault = Indoor unit temperature sensor, short circuit Error code = 04 Fault = Air conditioner indoor unit temperature sensor open. Error code = 05 Fault = Indoor unit temperature sensor is defective. Sensor resistance 10 Ohm. Error Code = 06 Malfunction = Outdoor heat exchanger temperature sensor open Error code = 07 Malfunction = Outdoor heat exchanger temperature sensor short circuit Error code = 08 Malfunction = Power to connect to error source Error code = 09 Malfunction = Float switch working Error code = 0A Malfunction = Outdoor unit temperature sensor open or open Error code = 0b Fault = Temperature sensor of the outdoor unit of the split system, - short circuit Composite picture of the Fujitsu, General-Fujitsu service manual. Original. Fault = no signal from Fujitsu, not normal Error code = 14 Fault = no signal from room sensor 2. Fujitsu outdoor LED unit. When the outside temperature drops, there is not enough pressure in the system. Add freon. error: heat and cooling (REVERSE CYCLE) wrong connection Fujitsu.

Error codes for Baloo air conditioners are required in order to timely identify the malfunction and contact the master to fix it. It should be noted that in some cases the slightest delay becomes critical, so it is better to monitor the appearance of information on the scoreboard.

True, the errors of Baloo air conditioners directly depend on the series. Because the hardware is different. software, which means that it informs a person about malfunctions in different ways. So, you should consider all possible codes depending on the series.

Mistakes on the example of Ballu MFS2

Errors of air conditioners Baloo series MFS2:

  • E1, E2, E3, E4 - Ballu air conditioner error, indicating that the temperature sensor was broken or shorted;
  • E6 shows the emergency activation of the protection of the outdoor unit;
  • E8 - Ballu air conditioner error, requiring cleaning of the electrostatic filter;
  • P4 - the compressor automatically turned off, as an error appeared on the evaporator sensor, which occurs when the temperature threshold is overcome;
  • P5 - this error code air conditioner Ballu shows when an error occurs on the condenser sensor;
  • P6 will prompt that the defrosting process has started automatically.

The number of codes shows how much information a person receives about the operation of his own equipment.

Accordingly, he can right moment contact specialists.

Below is the maximum full list codes of errors and malfunctions encountered in this technique in general.

Errors air conditioner Balu series BSC, BR, BV

  • E1, this air conditioner error code is displayed when the indoor air temperature sensor does not work properly;
  • E2 - evaporator temperature sensor error;
  • E5 indicates that an error occurred in the outdoor unit, which led to the automatic activation of the protection mode;
  • E6 are Baloo air conditioner errors showing a malfunction of the fan motor in the indoor unit.

It is immediately clear that the last three series have a much smaller number of codes. On the one hand, this shows how stable models are considered. On the other hand, the user receives less information, which often leads to difficult situations and additional diagnostics of cassette air conditioner models.

Air conditioner error codes are useful information that appears on the equipment screen. If you correctly recognize them, you will be able to find out exactly which malfunction should be fixed. Because of this, maintenance takes a minimum of time, which means that the owner does not have to suffer from a lack of equipment.

MDV air conditioners have a self-diagnostic system. This means that in the event of a malfunction, the air conditioner issues an error code. By the error code of the MDV air conditioner, it is quite easy to identify the problem.
This page lists different types of MDV hardware error codes:

ERROR CODES FOR HOUSEHOLD SPLIT SYSTEMS MDV
AURORA Series (MDSA)

Display Error value
E0
E1 EEPROM read error, indoor unit
E3 No indoor unit fan control
E4 Error on temperature sensor T1 (Troom)
E5 Error on sensor T2 (boiling)
EU Refrigerant leak
F1 Error on the T4 sensor (Outdoor block, Outside)
F2 Error on the TK sensor (Nar.blok, Tcondensation)
F3 Error on the T5 sensor (Nar.blok, Injection)
F4 EEPROM read error, outdoor unit
F5 No outdoor unit fan control
P0 IPM failure or overcurrent
P1 Supply voltage too low or too high
R2 Compressor overheating
P4 Inverter module error

FAIRWIND Series (MDSF)

LED operation LED Timer Display Error Code Meaning
Flashing 1 time Off E1
Flashes 2 times Off E2 Signal transition control error through 0
Flashes 3 times Off E3
Flashes 5 times Off E5 Thermistor error T1 indoor unit (air sensor)
Flashes 6 times Off E6 Indoor unit T2 thermistor error (pipe sensor)
Flashes 7 times Off E7 Outdoor unit TC thermistor error (24 and 28 kBTU only)
Flashes 2 times Glows EU Refrigerant leak detected
Flashes 8 times Off E8 reserve
Flashes 9 times Off E9 Interconnect Error (24 and 28 kBTU only)

Note: Depending on the model of the air conditioner, the error code may be displayed on the digital display or on the mode display LEDs.

ERROR CODES OF MULTI-SPLIT SYSTEMS MDV
Free Match outdoor units (MD*O-**HFN1)

Display Error value
E0 EEPROM checksum read error
E2 Interconnect error
E3 Communication error "control board - inverter board"
E4 Outdoor unit temperature sensor error
E5
E8 Outdoor unit fan speed control error
F1 Indoor unit A thermistor error
F2 Indoor unit B thermistor error
F3 Indoor unit With thermistor error
F4 Indoor unit D thermistor error
F5 Indoor unit E thermistor error
P1 P protection high (MD40-28HFN1, MD40-36HFN1, MD50-42HFN1)
R2 P protection low (MD40-28HFN1, MD40-36HFN1, MD50-42HFN1)
RZ Compressor current protection
P4 Protection for high discharge T
P5 Compressor overheating
R6 Inverter module failure
LP

Note: all error codes are automatically erased after 30 seconds after the error has been eliminated / disappeared, except for E2 / E3.

Indoor units of wall-mounted, duct and cassette types

Designations:
O-glows;
X-off;

Error code Description of the fault LED Timer LED operation
(flashing,
number
once)
E0 EEPROM checksum read error X 1
E1 Interconnect error X 2
E3 Indoor fan speed control error X 4
E4 X 5
E5 X 6
HER Condensate level sensor error (sensor or level) X 8
F0 O 1
F1 O 2
F2 O 3
F3 O 4
F4 O 5
F5 O 6
F6 O 7
F7 Reserve O 8
F8 Reserve O 9
F9 Reserve O 10
P0 III 1
P1 Too low or too high voltage III 2
RZ Too low outdoor temperature III 4
P4 Compressor error (see outdoor unit) III 5
P5 Mode conflict III 6
R6 Low pressure protection III 7
EU Refrigerant leak detected X 7
E2 Synchronization error X 3
R2 Compressor overheating III 3

Cantilever indoor units

Designations:
O-glows;
X-off;
/// - blinks at a frequency of 2 Hz.

Description of the fault Timer Lamp Operation Lamp
(flashing, number of times)
EEPROM checksum read error X 1
Interconnect error X 2
Indoor fan speed control error X 4
T1 thermistor error (indoor unit) X 5
T2 thermistor error (indoor unit) X 6
Overcurrent (not all models) O 1
T4 thermistor error (outdoor unit) O 2
TK thermistor error (outdoor unit) O 3
T5 thermistor error (outdoor unit) O 4
EEPROM checksum read error (outdoor unit), not all models O 5
Fan speed control error (outdoor unit) O 6
T2B thermistor error (indoor unit) O 7
Malfunction of inverter module (refer to outdoor unit codes) III 1
Too low or too high voltage III 2
Too low outdoor temperature III 4
Compressor error (See outdoor unit) III 5
Mode conflict III 6
Low pressure protection III 7

ERROR CODES OF SEMI-INDUSTRIAL SPLIT SYSTEMS MDV
Outdoor units

Error content LED 1 LED 2 LED 3
Phase rotation III X X
No phase (A, B) III X X
No phase (C) X X X
Low pressure protection III III X
Over current X X III
Board failure III X III
Open or short circuit of the TK sensor circuit X III III
Open or short circuit of the T4 sensor circuit X III X
Capacitor overheating protection III III III

Note: Slow blinking of LEDs 1, 2, 3 means that the system is in standby mode.

Indoor units of floor and ceiling (MDUE), channel (MDTB), cassette full-size (MDCD), cassette compact (MDCA3) types.

Protection or malfunction monitoring timer defrosting alarm error code
T air sensor X III X X E2
Refrigerant T sensor III X X X E3
Condensation sensor T (for 18 and 24 kBTU) X X III X E4
EEPROM read error III III X X E7
Exceeding the level of condensate in the sump X X X III E8
Refrigerant leak (if equipped) III X X III EU

indoor unit column type(MDFM)

Error code Protection or malfunction
P4 Evaporator T protection
P5 High T condensation protection
R9 Cold air protection
E1 T air sensor
E2 Refrigerant T sensor
E3 Condensation sensor T
E6 Outdoor unit malfunction
HS Defrost mode is running
P0 No communication between indoor unit control board and display (J2, S4)
Midea LCAC DC Inverter Series
Internal Cassette 4-Way Models
Error running timer defrost alarm Description
E1 Led2
Quik
Flash
No communication between indoor and outdoor unit
E2 Led 1
Quik
Flash
Faulty - shorted or broken air temperature sensor
E3 Led 1
Quik
Flash
Faulty evaporator temperature sensor (connector CN12 on the board)
E4 Led 1
Quik
Flash
Faulty temperature sensor at the outlet of the evaporator (connector CN7 on the board)
HER LED 4
Quik
Flash
Drain pan overflow error
E0 Led 3 Quik
Flash
Mismatch of air conditioner models
E7 Led 1
Quik
Flash
Faulty PROM, need to replace the board (microcircuit) or firmware
Ed LED 4
Quik
Flash
The external unit is faulty, see errors for it