What does h1 mean on the air conditioner. Deciphering error codes and malfunctions of Ballu air conditioners. Jax Air Conditioner Error Codes
![What does h1 mean on the air conditioner. Deciphering error codes and malfunctions of Ballu air conditioners. Jax Air Conditioner Error Codes](/uploads/e9b76e37871f6df8bde864fae9a3b285.jpg)
Read also
Error codes for air conditioners allow the service engineer to quickly find and efficiently fix faults.
Air conditioner diagnostics
This is the first thing to do before servicing or repairing it. Diagnostics of the air conditioner allows you to identify breakdowns and malfunctions in the system. Whether it is a lack of refrigerant that needs to be replenished, errors in the operation of the air conditioner, or malfunctions of the main components.
Timely and competent diagnostics of malfunctions will allow the service engineer to quickly and efficiently eliminate malfunctions. So, to return a healthy microclimate to the client's home or office.
All modern air conditioners have a developed self-diagnosis system. As a result of analyzing the state of the equipment, the system identifies the cause of the malfunction and displays the error code on the display (of the remote control, board or mode indicator). Below are the error codes for air conditioners (alarm code) various brands. Using this information, you can independently read the error code and repair the air conditioner. This will significantly save the time of equipment diagnostics and avoid inaccuracies in determining the nature and location of the breakdown.
Air conditioner error codes
We have selected for you information about error codes for air conditioners and split systems of different brands.
If you need an authorized service center for air conditioner repair - it's for us! EUROBUSINESS is your reliable partner!
Error codes for Beko BKN, AKN air conditioners
⊕ - blinking, 2 - on, 3 - off. If there are these errors, the operation of the air conditioner will be automatically terminated.
Error codes for Beko AKH, AKP, AS, BKH, BKP, BS air conditioners
Error codes for Beko inverter air conditioners BKC 090 INV, BKC 120 INV, BKL090 INV, BKL120 INV
If the BEKO air conditioner does not work, this is for us!
Error codes for Carrier air conditioners
If a malfunction is detected, the green indicator (P) and the orange indicator (R) flash at a frequency of 0.1 seconds, indicating a fault code. It should be noted that the orange indicator (R) corresponds to the tens in the number - the fault code. The green indicator (P) corresponds to the units in the number - the fault code.
There are 2 seconds between blinking orange and green indicators. The sequence is repeated at intervals of 4 seconds.
For example, fault code 13. Orange LED flashes once, both LEDs are off for 2 seconds, green LED flashes three times at 0.5 second intervals, both LEDs are off for 4 seconds.
The sequence is repeated until the fault is corrected. If the fault code is less than 10, then the orange indicator does not blink.
The code | Description |
2 | Room temperature sensor malfunction |
3 | Malfunction of the temperature sensor of the internal heat exchanger Tc |
6 | Malfunction of the reversing valve of the outdoor unit |
8 | Malfunction of the fan motor in the indoor unit |
9 | Power is not supplied to the indoor unit |
11 | Malfunctioning drain pump or other drainage problems |
12 | Software bug indoor unit(wrong addressing) |
13 | Configuration error |
14 | Signal Loss central system management |
15 | Malfunction of the indoor heat exchanger temperature sensor Tcj |
18 | Malfunction of the outdoor unit control unit (G-Tr short circuit protection) |
20 | Error in block position recognition circuit |
21 | Malfunction of the current sensor in the outdoor unit |
22 | Malfunction of the outdoor heat exchanger temperature sensor |
23 | Discharge temperature sensor malfunction |
24 | Outdoor unit fan failure |
26 | Other outdoor unit malfunction |
27 | Outdoor unit compressor blocked |
27 | Invalid discharge temperature |
29 | Outdoor unit compressor failure |
31 | Increased pressure in the circuit of the outdoor unit |
If the CARRIER air conditioner does not work, this is for us!
Error codes for Chigo air conditioners
If the CHIGO air conditioner does not work, this is for us!
Error codes for Daewoo air conditioners
Error code | Cause of malfunction |
F6 | PG motor faults |
F7 | Indoor TEMP sensor faults |
F8 | Indoor coil pipe TEMP sensor faults |
F9 | Outdoor coil pipe TEMP sensor faults |
If the Daewoo air conditioner does not work, this is for us!
Error codes for Fujitsu General air conditioners
Fujitsu General Ltd. introduced to the market New Product for diagnostics of split systems and multi-split systems GENERAL. The tool is a set of adapters connecting outdoor unit with a computer, and a PC program. With their help, a specialist conducting equipment diagnostics can see in real time the parameters of the compressor, fan motor, EEV, sensor readings, as well as an error log. In the process of testing, it is possible to record a work log with the issuance of a report.
The adapter is suitable for working with multi-split systems, as well as with most inverter split systems(wall, ceiling, channel, cassette).
Modern Fujitsu General air conditioners have a very advanced self-diagnosis system, according to the results of which the control system, when a particular malfunction is detected, blocks the operation of the entire device and at the same time reports the cause of the malfunction.
The Fujitsu General air conditioner control system reports any malfunctions by flashing an LED on the panel of the indoor (in some cases outdoor) unit. When a particular malfunction of the air conditioner is detected, the LEDs light up or flash in a certain sequence, which corresponds to the detected error. If the air conditioner control system has detected more than one error, then the malfunction with the highest priority is displayed first, and then all the others.
Error codes for Fujitsu General air conditioners are shown in the table.
Cause of malfunction | Error display | ||
OPERATION (red) | TIMER (green) | SWING (orange) | |
Indoor unit board failure | O | O | - |
Room temperature sensor wire open (indoor unit) | 2 X | O | - |
Short circuit in the room temperature sensor circuit (indoor unit) | 2 X | O | O |
Indoor unit piping sensor wire open | 3 X | O | - |
Short circuit in the indoor unit piping sensor circuit | 3 X | O | O |
Faulty indoor unit fan | 6 X | O | - |
For some models (see list *), depending on the error, the OPERATION, TIMER, SWING indicators work according to the following principle: O- fast blinking; X- slow blinking; - OFF
* Внутренний блок: ASG18FBAJ, ASG18FBBJ, ASG18UBAJ, ASG18UBBJ, ASG24FBBJ, ASG30FBBJ, ASG18FBBX, ASG18UBBN, ASG24FBBN, ASG24UBBN, AWG18FBAJ, AWG18FBBJ, AWG18UBAJ, AWG18UBBJ, AWG24FBBJ, AWG24UBBJ, AWG30FBBJ, AWG30UBBJ, AWG14UBBJ, ABG14FBBJ, ABG14FBBJ, ABG18FBBJ, ABG18FBBJ, ABG181BBJ, ABG181BBJ, ABG24FBBJ, ABG24FBBJ, ABG241BBJ, ABG241BBJ, AWG24FBAJ, AWG24UBAJ.
* Внешний блок: AOG18FNAK, AOG18FNBK, AOG18UNAKL, AOG18UNBKL, AOG24FNBK, AOG24UXBKL, AOG30UNBDL, AOG18FNBX, AOG18UXBXL, AOG24FXBX, AOG24UXBXL, AOG18FNAK, AOG18FXBK, AOG18UNAKL, AOG18UXBKL, AOG24FNBK, AOG24UXBKL, AOG30FNBDL, AOG30UNBDL, AOG14USBJ, AOG14FNBK, AOG14FXBX, AOG18FNBK, AOG18FXBX, AOG18UXBKL, AOG18UNBNL, AOG24FNBK, AOG24FXBX, AOG241XBKL, AOG24UXBXL, AOG24FXAD, AOG24UXADL
If the Fujitsu General air conditioner does not work, this is for us!
Error codes for Haier air conditioners
Repair of air conditioners HAIER (HAYER) is carried out on the basis of an analysis of the operating parameters of devices and fault codes.
If there are no errors or malfunctions, but the unit does not start, the start conditions may not be as required. In this case, the following standby codes will be displayed on the display of the head unit:
Error codes and malfunctions of indoor units of HAIER air conditioners
Remote display indication | Number of flashes LED5 / Timer | Description of the fault |
01 | 1 | Tai Ambient Temperature Sensor Malfunction |
02 | 2 | Malfunction of the temperature sensor of the heat exchanger TC1 |
03 | 3 | Malfunction of the temperature sensor of the heat exchanger TC2 |
04 | 4 | Dual Energy Source Temperature Sensor Malfunction |
05 | 5 | Indoor unit board EEPROM error |
06 | 6 | No communication between indoor and outdoor units |
07 | 7 | No communication between indoor unit and wired controller |
08 | 8 | Condensate drain error |
09 | 9 | Duplicate indoor unit address |
0A | 10 | Duplicate indoor unit central address |
Fault codes for outdoor unit | 20 | Corresponding malfunction of the outdoor unit |
Error codes and malfunctions of the inverter outdoor unit
Remote display indication | Error code | Description of the fault |
20-0 | Frost protection sensor t error TE1 | AD value is less than 11 (loop open) or greater than 1012 (loop closed) for more than 60 seconds. in cooling mode, if the sensor is faulty, the unit does not use its readings, except for the defrost function or for 3 minutes. after its completion; no alarm |
20-1 | Frost protection t sensor error TE2 | |
21 | Outside air temperature sensor error Ta | |
22 | Suction temperature sensor error Ts | AD value is less than 11 (loop open) or greater than 1012 (loop closed) for more than 60 seconds. in defrost mode or for 3 min. after its completion; there is no alarm. |
23 | Discharge temperature sensor error Td | After 5 minutes of compressor operation, the AD value is less than 11 (open circuit) or greater than 1012 (closed circuit) for more than 60 seconds. during start-up, in defrost mode or for 3 min. after its completion; no alarm |
24 | Toil oil temperature sensor error | AD value is less than 11 (loop open) or greater than 1012 (loop closed) for more than 60 seconds, (loop closed) for 60 seconds; if within 5 minutes Ta 2 -10°C or ET< -10®С, сигнала тревоги нет. |
The tables show only some of the HAIER air conditioner trouble codes. We remind you that HAIER air conditioners are technically sophisticated equipment. Error codes are provided for qualified and certified technicians. That is, for those who are professionally engaged in the repair of HAIER air conditioners, and not for ordinary users. Trust the repair of HAIER air conditioners to professionals.
If the Haier air conditioner does not work, this is for us!
Hisense Air Conditioner Error Codes
If a malfunction occurs, press the Sleep button on the remote control 4 times - the error code will light up on the 7-segment display (see table below). If there are several errors, then press the Sleep button 4 times again - the LED indicator will light up with the following error code.
The updated remote control, which has 4 modes of operation of the "Sleep" button, allows you to set 4 different combinations. When using it to check error codes, you must press the "Sleep" button 10 times. After that, error codes will start to be displayed.
The code | Cause of malfunction |
1 | Outdoor heat exchanger temperature sensor error |
2 | Compressor discharge temperature sensor error |
5 | Integral Power Module (IPM) protection trip |
6 | Operation of the overvoltage or undervoltage protection device in the AC mains |
7 | Communication error between indoor and outdoor units |
8 | Overload protection device |
10 | Communication error between two microcircuits (control and drive) in a printed |
11 | Outdoor unit EEPROM memory error |
12 | Tripping of the protection device at low outside temperatures |
13 | Tripping of the protection device as a result elevated temperature in |
14 | Outside air temperature sensor error |
15 | Compressor thermal protection trip due to overheating |
16 | Operation of the heat exchanger frost protection or overload protection device when the indoor unit is operating in heating mode |
17 | Reactive Power Compensation (PFC) |
18 | DC compressor start error |
19 | Compressor drive error |
Error codes for IGC air conditioners
IMS MINI (IMS-EM080NH, IMS-EM100NH, IMS-EM120NH, IMS-EM140NH, IMS-EM160NH)
The code | Malfunction |
CH | Liquid pipe thermistor failure |
CJ | Temperature sensor malfunction |
E6 | Suction tube temperature protection frequency limits "TS" |
E7 | Protection Frequency Limits average temperature external capacitor |
E8 | Protective stop of external capacitor |
E9 | Compressor Frequency Limits for Extreme High Temperature |
F4 | Low pressure sensor problems |
F5 | Low Pressure Transmitter Protection Limits for Ultra High or Ultra Low Frequency |
F6 | Low pressure safety shutdown for ultra-high or ultra-low frequency |
H8 | Constant frequency compressor overcurrent protection 1 |
H9 | Constant frequency compressor overcurrent protection 2 |
ON | Input voltage overvoltage and undervoltage protection |
NS | Incorrect phase sequence of fixed frequency compressor 1 |
HH | Wrong phase sequence frequency converter compressor |
HJ | Wrong phase sequence of fixed frequency compressor 2 |
J4 | Communication error with control panel and fan motor |
J5 | Error setting the address or load settings of the outdoor unit |
38 | Radiator temperature protection frequency limits |
39 | Radiator shutdown |
3A | DC fan protection |
3С | DC fan surge protection |
3H | Power on error or asynchronous fan operation |
3J | DC fan surge protection |
Error codes for Kentatsu air conditioners
Error codes Kentatsu KSVP-HF
E2 - room temperature sensor malfunction
EЗ - malfunction of the evaporator temperature sensor
E4 - malfunction of the temperature sensor of the outdoor unit
E6 - outdoor unit malfunction
E7 - EEPROM error
E8 - excess water level
Error codes Kentatsu KSKT-HF channel type
E0 - Faulty room temperature sensor
E1 - Faulty evaporator temperature sensor
E2 - Faulty outdoor unit temperature sensor
E3 - outdoor unit defective
E4 - faulty drain pump temperature sensor
E5 - EEPROM error
E6 - rising water level
Error codes Kentatsu KSFU models: KSFU/KSRU76HFDN3, KSFU/KSRU140HFDN3
P4 - thermal protection of the evaporator of the indoor unit
P5 - thermal protection of the capacitor of the external unit
P9 - protection of the defrost function or creation of a comfortable air flow
E1 - break or short circuit T1 temperature sensor circuits
E6 - outdoor unit protection
Error Codes Kentatsu KSGH/KSRH
Models: KSGH/KSRH21CFDN1 KSGH/KSRH26CFDN1, KSGH/KSRH35CFDN1 KSGH/KSRH53CFDN1, KSGH/KSRH21HFDN1 KSGH/KSRH26HFDN1, KSGH/KSRH35HFDN1
E1 - EEPROM error (non-volatile memory on the board)
E2 - zero crossing error
EЗ - abnormal fan speed
E4 - compressor current protection tripped 4 times
E5 - indoor air temperature sensor shorted / broken
E6 - evaporator temperature sensor shorted / broken
Kentatsu Error Codes floor type KSFU70XFAN1 /KSRU70HFAN1, KSFU120XFAN3 / KSRU120HFAN3
P4 - evaporator temperature protection
P5 - condenser temperature protection
P7 - Discharge temperature too high. Compressor protection enabled
P9 - too low outdoor temperature, when it rises, the protection will turn off automatically
P10 - outlet pressure protection
P11 - suction pressure protection
P12 - overcurrent protection
E1 - indoor air temperature sensor T1 shorted / broken
E2 - evaporator temperature sensor T2 shorted / open
E3 - T3 condenser temperature sensor short/open
E4 - outdoor temperature sensor closed T4 shorted / broken
E5 - communication between the indoor and outdoor units is broken
E6 - outdoor unit protection
E10 - compressor suction pressure error
E13 - compressor phase error
E14 - incorrect compressor phasing
HS - start defrost
If the Kentatsu air conditioner does not work, this is for us!
Error codes for LG air conditioners
The code | Cause of malfunction |
F01 | Open / short circuit room room (air) temperature sensor of the indoor unit |
F02 | Open/short circuit of the pipe temperature sensor of the indoor unit |
F03 | Lack of communication between the control panel and the main control board for more than 2 minutes |
F04 | Open / short pipe temperature sensor of the outdoor unit |
F05 | Open / short circuit room air temperature sensor of the outdoor unit |
CH01 | Malfunction of one of the thermistors of the board (break or short circuit) of the indoor, wall-mounted unit of the split system - control of the temperature of the incoming air and the tube of the gas circuit of the air conditioner |
CH02 | Malfunction of one of the thermistors (break or short circuit) of the outdoor unit: inlet air temperature sensor or gas circuit pipe temperature sensor |
CH03 | The air conditioner works simultaneously for heating and cooling the air |
CH04 | Compressor overload protection system included |
CH05 | Communication error between the indoor and outdoor units of the split system |
CH06 | The current consumption of one or more actuators of the outdoor unit-relay was briefly above the norm |
CH07 | Current consumption of the entire outdoor unit long time was above normal |
CH08 | Fan motor failure |
CH09 | 4-way valve malfunction |
CH10 | The thermistor for controlling the temperature of the compressor housing of the split system is faulty (open or short circuit) |
LGMV is a mobile application developed by the manufacturer for remote monitoring of operating parameters of LG air conditioning systems. The app helps engineers evaluate Current state equipment. The analysis is based on a multi-year operation cycle. The program helps not only to quickly identify problems in the system, but also gives recommendations for resolving the issue.
The LGMV diagnostic system provides monitoring of system operating parameters, prevention and prevention of system malfunctions. All this certainly simplifies diagnostics and commissioning. LGMV consists of a wireless communication module and a free smartphone app. To use the LGMV mobile application, an exclusive Bluetooth module is required, the corresponding connector of which must be connected to the CN-LGMV port on the main board of the outdoor unit.
LGMV main features:
Visual display of key information about the operation of the air conditioner.
Graphic indication of pressure and other parameters.
Controls the operation mode of the indoor units when the unit is connected to the outdoor unit.
Saving data on the operation of the air conditioner as a file.
Operation report — the result of the testing operation is generated into an HTML document.
Error number indication and support for error search in the list from PDF document.
Mobile LGMV can be downloaded, for example, from Google Play as a product of LG Electronics, Inc. as a tool for Maintenance, troubleshooting for LG air conditioning systems. The LGMV mobile application uses a limited resource on a smartphone and processes data in real time. Data monitoring may be difficult or data may not be fully saved if the performance of the smartphone is poor.
It is recommended to use a high performance smartphone. If system resources are insufficient due to other Internet applications that are enabled, data monitoring may fail in addition to monitoring. The monitoring function and saving function may not work fully. And also Bluetooth communication connection can be disabled. In addition, the application may be disabled due to a lack of resources or an unexpected error.
The communication level may increase depending on the number of outdoor and indoor units. Bluetooth transmission distance may be shortened to the point of turning off data transmission depending on the weather or conditions. environment(electromagnetic waves or obstacle), etc. It is recommended to use the Bluetooth module for a short distance.
If the LG air conditioner does not work, this is for us!
Error codes for MDV air conditioners
Error indication on MDV indoor unit
If you need diagnostics of the MDV air conditioner - this is for us!
Error indication on external MDV unit
E0 | eeprom error |
E1 | Error on the temperature sensors of the indoor unit 1 |
E2 | Error on the temperature sensors of the indoor unit 2 |
E3 | Error on the temperature sensors of the indoor unit 3 |
E4 | Outdoor unit temperature sensor error |
E5 | High or low voltage protection |
E6 | Error on the temperature sensors of the indoor unit 4 |
E7 | No communication between control and inverter boards |
P0 | Compressor overheating protection |
P1 | Protection by high pressure- only for M4OCi |
P2 | Protection by low pressure- only for M4OCi |
P3 | Compressor overcurrent protection |
P4 | Inverter module protection tripped |
P5 | Low outdoor temperature protection -7°C |
P6 | High condensing temperature protection |
If the MDV air conditioner does not work, this is for us!
Mitsubishi Electric Air Conditioner Error Codes
If the Mitsubishi Electric air conditioner does not work, this is for us!
Mitsubishi Heavy Air Conditioner Error Codes
If the air conditioner does not work Mitsubishi Heavy- it's for us!
Error codes for Wisnow air conditioners
If the Wisnow air conditioner does not work, this is for us!
Error codes for Polaris air conditioners
If the Polaris air conditioner does not work, this is for us!
Sanyo Air Conditioner Error Codes
Description of the malfunctions that are indicated on the board of the SANYO W-ECO MULTI SYSTEM outdoor unit. Valid for SPW-CR1503GDYH8, SPW-CR1903GDYH8, SPW-CR703GDCH8, SPW-CR903GDCH8, SPW-C1503GDYH8, SPW-C1903GDYH8, SPW-C703GDCH8, SPW-C903GDCH8.
If the Sanyo air conditioner does not work, this is for us!
Sharp Air Conditioner Error Codes
For example, fault indication in SHARP air conditioners models AY-A184E / AE-A184E, AY-A244E / AE-A244E.
If the Sharp air conditioner does not work, this is for us!
Error codes for Toshiba air conditioners
The code | Malfunction |
00-0s | indoor air temperature sensor error or indoor unit board error |
00-0d | error of the temperature sensor of the radiator or control board |
00-11 | defective board or fan motor |
00-12 | need to replace control board |
01-04 | fuses on the board burned out, incorrect interconnection, board burned out |
01-05 | inverter board error |
02-14 | inverter overcurrent |
02-16 | short circuit between compressor windings |
02-17 | current sensor error |
02-18 | error of temperature sensors, PC board |
02-19 | error temperature sensor TD, PC boards |
02-1a | outdoor unit fan error - overcurrent, blocked, burnt motor or board |
02-1b | condenser temperature sensor defective or board |
02-1c | compressor did not start within 20 seconds |
03-07 | lack of refrigerant, inverter board error |
03-1d | defective compressor |
03-1e | suction tube sensor error TD, not enough refrigerant |
03-1f | compressor does not work due to supply voltage, overload of the refrigeration circuit |
03-08 | four-way valve malfunction |
If the Toshiba air conditioner does not work, this is for us!
The work performed during the diagnostics corresponds to the work performed during. The only difference is that during the diagnostics, all the main parameters of the equipment operation are checked and recorded, and when after-sales service identified deviations from the norm are eliminated.
The list of works in the diagnosis of air conditioning
During the diagnosis of the air conditioner, firstly, visual inspection for the absence mechanical damage. Not only hull, but also hydraulic and electrical parts of the equipment are inspected. In addition, the reliability of the fasteners of the external and internal units is checked. As well as the quality of the clamps of all contact connections electrical equipment. Before turning on the equipment, you need to check the status air filters. They must be not only clean, but also without damage. After inspection, as a rule, switching to the "cooling" mode is performed. Use the remote control to test the system.
During the functional test, the indication of the air conditioner modes is evaluated, as well as the operation of the mechanically driven exit blinds. One of the indirect indicators of the efficiency of the system is the control of the temperature of dry air at the inlet and outlet of the evaporator. With the help of pressure gauges, the average suction / discharge pressure is measured (with free access to the outdoor unit). Of course, it is mandatory to check the tightness of the connection between the indoor and outdoor units. In addition, you need to make sure that there are no leaks in drainage system conditioner.
If something went wrong
The specialist can also judge the nature of the malfunction by the “behavior” of the air conditioner. For example, if the air conditioner turns on and immediately turns off, after which an error message is displayed - most likely, the matter is in the sensors (malfunction of the air temperature sensors or the evaporator).
If the air conditioner turns on, runs for 15-20 seconds, and then turns off, the indoor unit fan motor is most likely defective (rotation speed is lower than the set rpm).
If the air conditioner does not turn on at all and at the same time all the LEDs flash (or do not light up), most likely, the control circuit board has failed.
Simultaneous flashing of all indicator lamps of the air conditioner, as a rule, means only a failure of the program settings of the control board. Most likely, this is due to the non-compliance with the GOSTs of the network parameters, for example, due to a power surge in the network. It is not difficult to eliminate this malfunction - it is enough just to reprogram the main control board. Since information about codes is provided only to authorized service centers, in this case you need to contact our experts.
Before…
If your air conditioner does not work, first of all make sure that the air conditioner is securely connected to the outlet. Check the circuit breaker or fuse on the supply line, if necessary restart the circuit breaker or replace the fuse. Read the user manual again and make sure all modes are set correctly.
Doing it yourself will save you money. Because in many cases the engineer you called, after doing what you can easily do yourself, will charge you for the false call.
If these steps do not help, then contact the sales organization that sold you the air conditioner. Or contact an authorized service center of the air conditioner manufacturer. Without a doubt, this is the best, fastest and most reliable way to get your air conditioner back up and running. The sales organization that sold the air conditioner should give you information on how to contact them. This information is available not only in the warranty card, but also on the manufacturer's website in the appropriate regional section.
Air conditioner test mode
To facilitate diagnostics, modern air conditioners have a so-called test mode. Compared to the operating mode, the air conditioner turns on in cooling mode and does not respond to sensor readings and air temperature. That is, in the test mode, the air conditioner will function as long as it is necessary for the service engineer to study the operation of the system units. After turning off the test mode, the air conditioner will return to normal mode work.
Samsung air conditioners also have a test mode. To enter the test mode, press the on / off button on the indoor unit and hold it for five seconds. At the same time, the temperature indicator displays the installed option. software settings with a second interval, for example, 0b0000-1730F8: 0b00001730F80b (only for models with a temperature indicator).
When testing the operation of the air conditioner, the cooling mode is switched on with the following restrictions:
- The compressor is forced to run in cooling mode without turning on/off according to the set internal temperature, without defrosting mode;
- Vane, guide air flow up/down - turn up/down mode;
- The indoor fan rotates at high speed.
AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Vitek, digital display for air conditioner series fault:
- Display mode = E4
- Priority level display = 1 Non-mitsubishi52_63_71he-s power supply failure = Plastic temp sensor is abnormal.
- Display mode = E1 Priority level display = 2
- Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3
- Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = E2 Priority level display =
4
2. H series, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Renova (except KFR-25G/H) h3 HA HB series fault display:
- Power supply failure = PG feedback engine abnormal
- Priority level display = 1 Power supply failure = Plastic temp sensor abnormal Display mode = Timer LED blinks 1 time every 8 seconds
- Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds
- Priority level display = 3 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 1 time every 1 second
- Priority level display = 4
3. Series H (Y) air conditioner model remote display, removable panel AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu:
- Power supply failure = Motor feedback PG abnormal Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1
- Power supply failure = Plastic temp sensor. abnormal Display mode = Timer LED flashes 1 time every 8 seconds Priority level display = 2
- Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3
- Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = Timer LED flashes 1 time every 1 second Priority level display = 4
4. E. E. E. EU EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display air conditioner series AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Troubleshooting:
AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu power supply failure = Motor feedback PG abnormal Display mode = E4 Priority level display = 1
E1 or EL - as a common nutrition mistake.
Power supply failure or, in Russian, mains voltage< 210 В (сработала защита – токовая нагрузка) = Датчик темп ненормально Режим отображения = E1 Отображение уровня приоритета = 2
E1 - pretty common mistake, just yesterday I encountered.
- The reasons for E1 are obvious - insufficient voltage in the network< 210 В. При пуске компрессора происходит дополнительная просадка напряжения, токовая нагрузка max.
- Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3
1
1
5. All other E series except EA EU E.M.E.U.Z. EAA EAD:
Power supply failure = PG motor feedback abnormal
Display mode = Timer LED blinks 4 times every 8 seconds
Priority level display = 1 Power supply failure = Plastic temp. abnormal Display mode = Timer LED blinks 1 time every 8 seconds
Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3
6. QA QB QD digital display of AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Vitek, Renova air conditioners - malfunctions, error codes:
- Power supply failure = PG motor feedback abnormal Display mode = E4
- Priority level display = 1 Power supply failure = Plastic temp sensor abnormal Display mode = E1
- Priority level display = 2 Power supply failure = Copper temperature sensor abnormal
- Display mode = E3 Priority level display = 3 Power supply failure = overcurrent oprotection
- Display mode = E6 Priority level display = 4
1
1
7. QC QQ light display air conditioner series fault:
- Power supply failure = PG motor feedback abnormal
- Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1 Power supply failure = Plastic temp sensor abnormal
- Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2 Power supply failure AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu = Copper temperature sensor abnormal
- Display mode = Timer LED blinks 3 times every 8 seconds Priority level display = 3 Power supply failure = over current oprotection
- Display mode = Timer LED blinks 6 times every 8 seconds Priority level display = 4
1
1
8. Display faults of 18000BTU ~ 24000BTU, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Renova series - wall mounted air conditioner series:
- Numbers for digital tube displays:
- Power supply failure = PG motor feedback abnormal
- Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2
- System errors = turns off Power supply failure = Plastic temp sensor abnormal Display mode =
- Timer LED blinks 2 times every 8 seconds Priority level display = 3 System errors = turns off
- Power supply failure = Copper temperature sensor abnormal Display mode = Timer LED blinks 8 times every 8 seconds Priority level display = 4
- System errors = not turning off Digital tube displays: Power supply failure = PG motor feedback abnormal Display mode = E1
- Priority level display = 2 System errors = turns off Power supply failure = Plastic temp sensor abnormal Display mode = E3
- Priority level display = 3 System errors = turn off Power supply failure = Copper temperature sensor abnormal Display mode = E2 Priority level display = 4
- System errors = does not turn off
Error codes are needed if your split system is broken, how to fix the problem, what you need to know, including the consumer, so that you are not cheated at the service center. Split system error codesPossible breakdowns of refrigeration equipment are determined by error codes, it is not necessary to be a specialist to determine the cause of the breakdown by codes The main directions for troubleshooting are simple ... If the error code F-1, F-2, F-3, F-4, F-5, F-6, F-7, etc. is displayed, then the problem must be sought in temperature sensors and everything connected with them on the control board does not pass the signal, open or short circuit. If the error code E-1, E-2, E-3, E-4, E-5, E-6 ... etc. is displayed. E-0, EL, while the air conditioner either starts and works for some time, or does not start at all, then we are looking for a solution to the problem with the operation of the split system in the power unit: the reasons are different ... from the complete failure of the start signal to the critical current characteristics to turn off the system . As an example: the bearing of the fan of the indoor unit is pinched, the fan impeller rotates but at insufficient speed, the hall sensor or the torque sensor does not send a signal to the control board, the split system gives an error E 1 ... E-L after 1-5 minutes, the problem is found. Malfunctions and malfunctions of Toshiba air conditioners, fixing errors in the operation of your favorite split system
Toshiba air conditioning systems are easy and simple to repair if you have a service manual, we give you the opportunity to become at least a little smarter for free.Toshiba RAV series - air conditioner problems or error codes Samsung Air Conditioner Remote ControlAir conditioner control panel Samsung, is not just a set of buttons that set certain predefined functions air conditioner, but it is also a programmer, tasks the firmware of the split system board itself.
But, if, nevertheless, your Samsung has a nuisance, - Samsung broken down, do not rush to call the air conditioner repair service center, try to flash the air conditioner board and return the settings of the Samsung split system to the factory settings.Samsung - air conditioner trouble codes | Samsung board firmware Sources: error codes for popular air conditioners Error Code Air Conditioner...welcome to the page with direct links to sources of information about error codes, malfunctions of industrial split systems and VRV air conditioning systems, the source sites also provide information about chiller-fan coil systems, fault codes and main breakdowns climatic equipment. Air Conditioner Hardwired Remote Controller System Error Codes.Mitsubishi, Fujitsu, Acson, Dantex, Mitsubishi-Heavy, Chofu, Akira, General Electric, General Climate , Gree, General-Fujitsu, Sanyo, Daikin, Toshiba, Electrolux, Kentatsu, Neoclima, Midea, McQuay, Panasonic, AUX, West, Whirlpool, Yamaha, Euronord, Pioneer, Mitsubishi-Electric, Hyundai, Dantex classik Toyo, Chigo, DAX, RODA, Renova, Quattroclima, Lessar, Supra, Saturn, Ferroli, Hualing, Tadiran, Daewoo, Airwell, York... If you did not find your air conditioner in this long list, don't worry, click on the source link... everything is there. error code air conditioning | Error codes, originals pdf fileDamaged thermistor1) Check the transmission wire. 2) Check with another remote controller. If "EO" is still indicated, replace the internal controller board. If another checkered code appears. replace the original remote controller. Error codes. Mitsubishi ElectricP1 Abnormality of room temperature thermistor (RT1) 1) Bad contact of thermistor 2) Damaged thermistor 1) Check the thermistor. 2) Measure the resistance of the thermistor. Normal resistance should be as follows. 32°F-15k | 86°F ..... 4.3k 50°F...... 9.6k 104°F..... 3.0k 68°F...... 6.3k If resistance is ok, replace inner tip dispatchers. P2 Abnormality of internal coil thermistor (RT2) P3 Signal transmission error (The remote controller does not respond to the controller's internal signal.) 1) Bad contact of the transmission wire 2) Signal transmit/receive circuit is incorrect. 3) Wrong operation due to noise wave emitted by other appliances 1) Check the transmission wire. 2) Check with another remote controller. If "P3" is still indicated, replace the inner board. If another checker code appears, replace the original remote controller. 3) Short circuit between and from CN40 and attach CN40 to the following units. Second unit in dual control Second and third units in triple control Sub units in group control P4 Leak sensor abnormality 1) Poor transmission contact cablesAir conditioners Mitsubishi-Electric | Split system malfunctions, error codes Break down much more oftenFrequent breakdowns of air conditioners of the budget series are due to the fact that split systems are lower price category break much more often, since almost all components, parts, and mechanisms of coolers are minimized at a price. Error codes for air conditioner groups - DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Renova - with interchangeable printed circuit boards of the same name. Error codes for entire groups budget air conditioners, - DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Vitek, Daihatsu, Renova, - with interchangeable circuit boards of the same name. Firmware for the board of cooling devices of these brands by default. E1 or EL - pay close attention to this malfunction in the operation of the air conditioner, it is usually not related to the quality of the cooler, this is an external system error associated with poor-quality voltage in the power supply network. Error display code | AUX, DAX, JAX, Pioneer, Hansa, Saturn, Vitek, Rolsen, Yamatsu, DaihatsuBreakdowns of Mitsubishi-Heavy split systemsDisplay readings on the Mitsubishi remote control. EA error code Why doesn't Mitsubishi work? Incorrect installation of the Indoor / Outdoor, - unit. exceeds the number of internal inclusions, connecting block, break. Check temperature and pressure sensors... Error code Eb Malfunction of the split system. Incorrect installation of the Indoor / Outdoor, - unit. (Incorrect installation, check correct connection) Check temperature and pressure sensors... EU error code Malfunction. Time trigger, start delay. Check temperature and pressure sensors... Error code E6 Malfunction. Internal / external, - control board malfunction (signal receiver does not work). Closed when checking Error code E7 Malfunction of the Mitsubishi air conditioner. Internal / external, - incorrect signal formation (incorrect connection, break, short circuit). Closed when checking Error code E8 Mitsubishi-Heavy air conditioner malfunction. Internal / external, - control board malfunction (signal receiver does not work). Mitsubishi-Heavy, troubleshooting the cooling circuit. Troubleshooting the cooling circuit. Check temperature and pressure sensors... Error code E9 Air conditioner malfunction. Internal / external, - incorrect signal formation (incorrect connection, break, short circuit). Check temperature and pressure sensors... Mitsubishi-Heavy Cooling System Malfunctions, Service ManualSearch faults and breakdowns of split systems McQuay/Acson, it is necessary to start with the common causes of breakdowns and equipment failure. Common causes include electrical malfunctions and malfunctions of the refrigeration circuit. Name of McQuay/Acson equipment, their analogues and modifications. Carrier air conditioner brokenIf your Carrier air conditioner has broken down, then something extraordinary and beyond reason has really happened. Carrier are so reliable and durable that it is extremely difficult to break this device even with a strong desire. But, anything happens ... meteorites fall ... Malfunctions of Carrier split systems The main malfunction of LG air conditioners ...As a rule, the main malfunction of LG air conditioners is insufficient voltage of the power supply network. Chubaisyats spoil LG air conditioners. How to fix a breakdown? How to identify a malfunction using blinking indicators. What do these blinks mean? How many times this or that indicator lamp blinked, you can see based on the figure above. How to find an error using indicators - LEDs of the indoor unit of air conditioners.How many times this or that indicator lamp blinked, you can see based on the figure above.
Haier air conditioners also break like everyone else Appliances, fault codes and possible errors in the split systems of this brand, you can easily determine the fault table on the page of our website. The operation algorithm of Haier Electric Corporation air conditioners is so simple that even a novice amateur repairman can figure it out.If all repair work carried out sequentially, the result simply must be positive. Haier Electric Corporation error codesIncorrect maintenance of the Haier air conditioner is the main malfunction. Crooked hands are the reason that disables Haier split systems.
Panasonic air conditioner repair. Finding and fixing system bugs. Error codes and malfunctions of Panasonic air conditioners (Panasonic). Panasonic how to solve an unexpected problemTo be fair, we note that Panasonic air conditioners also break.Breakdowns and malfunctions in split systems under the well-known multi-national brand National Panasonic, as well as the main malfunctions of split systems are presented in our article on the repair of this type of coolers. If your Panasonic blinked like Christmas tree and does not want to execute the commands given from the air conditioner control panel, then this article will help you figure out and fix an unexpected problem. Everything is being repaired! Even split systems National Panasonic. In fairness, we note that Panasonic air conditioners also break down. Finding and fixing system bugs. Panasonic error codes.
In order to order a panasonic brand air conditioner repair from us, just call our operator and leave a request. … repair of Panasonic air conditioners. Name of service. Price, rubPanasonic, air conditioner repair | Finding and fixing system errors Gree, like an air conditioner, is functionally simple, so there are not many error codes. Downsides of simplicity Gree air conditioners, - these are weak varistors of the control board, insufficient smoothing of currents during voltage surges. A trifle, but it must be borne in mind when repairing air conditioners Gree and their analogues. Self-diagnosis of Gree air conditionersThe internal self-diagnosis of Gree air conditioners is unified and almost identical in error positions to inexpensive air conditioners, such as Pioneer, General Climate, Lessar and others.Everything is similar and almost everything is being repaired: you just need to have a little patience and confidence in the success of the repair company. Everything will be fine...Gree: Error and Fault Codes | Easy Repair Daikin error codes... Faults on these glorious Daikin Daichi air conditioners. Air Conditioner Troubleshooting Table Daikin. Full size Images. 2500*2000 link. Error codes, click on the Daikin remote control buttons.Which buttons to press and when? Schematic version. The split system error code will be displayed on the screen. It is very convenient for self-testing. And then there are times when a "master" of repair comes and ... let's wind up the price for repairing an air conditioner from the eyes of a client. And there the problem is a penny. As an example, wipe the thermal sensor of the indoor unit with a cloth, or simply clean the filter ...Independent troubleshooting of Daikin air conditioners. Pre-repair diagnostics of the Daikin split system.Daikin error codes | Daikin air conditioner problems Fault codes Fujitsu, General-Fujitsu | Which buttons to press and when? RepairWe look in the book and see ... what we need. Fault Paradox Fujitsu, General-Fujitsu. Fault codes for split systems Fujitsu, General-Fujitsu. Fujitsu, General-Fujitsu, Fuji. Air conditioning trouble codes, system error control or System Controller Error Fujitsu. When EE: EE is displayed on the Fujitsu remote control, press the power saving button and the mode change button at the same time for more than 3 seconds. Error codes will be shown on the display. (1) stop the air conditioner. (2) Press the master control button and the fan control button at the same time for 2 seconds or more to start the test run (3) Press the start/stop button to stop the test run Error code = 01 Fault = Communication error (indoor unit with outdoor unit) Error code = 02 Fault = Room temperature sensor open, open circuit Error code = 03 Fault = Indoor unit temperature sensor, short circuit Error code = 04 Fault = Air conditioner indoor unit temperature sensor open. Error code = 05 Fault = Indoor unit temperature sensor is defective. Sensor resistance 10 Ohm. Error Code = 06 Malfunction = Outdoor heat exchanger temperature sensor open Error code = 07 Malfunction = Outdoor heat exchanger temperature sensor short circuit Error code = 08 Malfunction = Power to connect to error source Error code = 09 Malfunction = Float switch working Error code = 0A Malfunction = Outdoor unit temperature sensor open or open Error code = 0b Fault = Temperature sensor of the outdoor unit of the split system, - short circuit Composite picture of the Fujitsu, General-Fujitsu service manual. Original. Fault = no signal from Fujitsu, not normal Error code = 14 Fault = no signal from room sensor 2. Fujitsu outdoor LED unit. When the outside temperature drops, there is not enough pressure in the system. Add freon. error: heat and cooling (REVERSE CYCLE) wrong connection Fujitsu. Error codes for Baloo air conditioners are required in order to timely identify the malfunction and contact the master to fix it. It should be noted that in some cases the slightest delay becomes critical, so it is better to monitor the appearance of information on the scoreboard. True, the errors of Baloo air conditioners directly depend on the series. Because the hardware is different. software, which means that it informs a person about malfunctions in different ways. So, you should consider all possible codes depending on the series. Mistakes on the example of Ballu MFS2Errors of air conditioners Baloo series MFS2:
The number of codes shows how much information a person receives about the operation of his own equipment. Accordingly, he can right moment contact specialists. Below is the maximum full list codes of errors and malfunctions encountered in this technique in general. Errors air conditioner Balu series BSC, BR, BV
It is immediately clear that the last three series have a much smaller number of codes. On the one hand, this shows how stable models are considered. On the other hand, the user receives less information, which often leads to difficult situations and additional diagnostics of cassette air conditioner models. Air conditioner error codes are useful information that appears on the equipment screen. If you correctly recognize them, you will be able to find out exactly which malfunction should be fixed. Because of this, maintenance takes a minimum of time, which means that the owner does not have to suffer from a lack of equipment.
MDV air conditioners have a self-diagnostic system. This means that in the event of a malfunction, the air conditioner issues an error code. By the error code of the MDV air conditioner, it is quite easy to identify the problem. ERROR CODES FOR HOUSEHOLD SPLIT SYSTEMS MDV
FAIRWIND Series (MDSF)
Note: Depending on the model of the air conditioner, the error code may be displayed on the digital display or on the mode display LEDs. ERROR CODES OF MULTI-SPLIT SYSTEMS MDV
Note: all error codes are automatically erased after 30 seconds after the error has been eliminated / disappeared, except for E2 / E3. Indoor units of wall-mounted, duct and cassette types Designations:
Cantilever indoor units Designations:
ERROR CODES OF SEMI-INDUSTRIAL SPLIT SYSTEMS MDV
Note: Slow blinking of LEDs 1, 2, 3 means that the system is in standby mode. Indoor units of floor and ceiling (MDUE), channel (MDTB), cassette full-size (MDCD), cassette compact (MDCA3) types.
indoor unit column type(MDFM)
Internal Cassette 4-Way Models
|